The V3-BTZB unit cannot be turned off after installation, so any doors installed with the 
V3-BTZB etc. must not operate near health care facilities when any regulations posted in 
these areas prohibit the use of wireless phones or two-way radios. Hospitals and health 
care facilities may be using equipment that could be sensitive to external RF energy. 
 
 

Potentially Explosive Atmospheres 

The V3-BTZB unit cannot be turned off after installation, so any building installed with V3-
BTZB etc. must not be located in an area with a potentially explosive atmosphere and 
obey all signs and instructions not to use V3-BTZB in such areas. Sparks in such areas 
could cause an explosion or fire resulting in bodily injury or even death. 
 
Areas with a potentially explosive atmosphere are often, but not always marked clearly. 
Potential areas may include: fueling areas (such as gasoline stations); below deck on 
boats; fuel or chemical transfer or storage facilities; areas using liquefied petroleum gas 
(such as propane or butane); areas where the air contains chemicals or particles (such as 
grain, dust, or metal powders); and any other area where it would normally be advisable 

not to

 install the V3-BTZB. 

 
 

Specific Human Absorption Rates (SAR) 

THE V3-BTZB UNIT IS NOT DESIGNED TO BE WORN ON A PERSON’S BODY. AS 
SUCH, BODY WORN TEST POSITIONS FOR THE V3-BTZB UNIT  
ARE NOT REQUIRED BY EITHER THE IEC 62311 FOR BLUETOOTH LE OR 
FCC/IEEE/ICNIRP REQUIREMENTS FOR BLUETOOTH LE. 
 
The V3-BTZB unit is not intended for handheld use or to be worn on the body. A minimum 
separation of eight (8”) inches (20 cm) is to be maintained between the V3-BTZB and any 
persons’ body. Additional information on Specific Absorption Rates (SAR)

 

Battery Safety Information 

Adhere to the following guidelines to avoid the risk of fire or explosion: 
 
1.  Dispose of the used battery according to the instructions provided with the battery. 
2.  Do not drop, puncture, disassemble, mutilate, or incinerate the battery. 
3.  Touching both terminals of a battery with a metal object will short circuit the battery. Do 

not carry batteries loosely if the contacts may touch coins, keys, and other metal 
objects (such as in pockets or bags). 

4.  Do not stack batteries taken out of the carry case. 
5.  Do not heat the batteries to try to rejuvenate their charge. 
6.  Do not exceed the temperature ranges or other environmental conditions specified by 

the battery manufacturer. 

7.  Never use the V3-BTZB without the battery cover installed. 
 
 
 

 

Summary of Contents for V3-BTZB

Page 1: ...V3 BTZB Danalock V3 BTZB Technical Manual v 1 5 May 2017 Page 1 V3 BTZB Technical Manual Version 1 5 May 2017...

Page 2: ...livered standard content 11 Installing the unit 11 Practical installation advice 12 Functionality check 13 LED signals 13 Electro mechanical lock classification 14 Product family 15 Accessories 15 War...

Page 3: ...control after sales service whose agreement is mandatory prior to any replacement Any shipping costs are at the Customer s expense The warranty does not apply to visible defects Also excluded are defe...

Page 4: ...D ANY EMBEDDED SOFTWARE FIRMWARE AND UPDATES THERETO INCLUDING WITHOUT LIMITATION DAMAGES FOR LOSS OF BUSINESS PROFITS BUSINESS INTERRUPTION LOSS OF DATA OR ANY OTHER PECUNIARY LOSS REGARDLESS OF WHET...

Page 5: ...ipment supporting Bluetooth Low Energy 2400 2483 5 MHz and Zigbee 2400 2483 5 MHz ACMA AUS NZ The V3 BTZB product complies with the Australian New Zealand Radio communication Act for radio terminal eq...

Page 6: ...ite links to the My Danalock site from Poly Control ApS and it is found at my danalock com V3 BTZB devices can be integrated to the My Danalock site Safety first Simple Guidelines Please follow these...

Page 7: ...oors or internal residential doors EN 14846 category of use classification grade 0 Durability door mass and closing force and security Physical attack The type of door i e mass and closing force durab...

Page 8: ...t is shielded from RF signals However certain electronic equipment may not be shielded against the RF signals generated by the V3 BTZB unit Pacemakers The Health Industry Manufacturers Association rec...

Page 9: ...al powders and any other area where it would normally be advisable not to install the V3 BTZB Specific Human Absorption Rates SAR THE V3 BTZB UNIT IS NOT DESIGNED TO BE WORN ON A PERSON S BODY AS SUCH...

Page 10: ...ile Internet browsers you use and information about the way you use the Application Data retention policy managing your information We will retain User Provided data for as long as you use the Applica...

Page 11: ...ning and disclosing information all of which activities will take place in Scandinavia Europe Middle East Asia and United States Contact us If you have any questions regarding privacy while using the...

Page 12: ...the unit Practical installation advice Please follow the installation guide carefully It is available on the danalock site that is found at https guide danalock com Be aware that multiple installatio...

Page 13: ...ation Constant red light till finishes Manually lock unlock when not calibrated Constant yellow light till finishes Lock has been latched successfully Constant yellow till fails then one red blink Loc...

Page 14: ...ce from other Bluetooth devices Apple products will typically be ranked higher than other Bluetooth devices Electro mechanical lock classification The V3 BTZB is categorized as an electro mechanical l...

Page 15: ...e for the V3 series Description Bluetooth Wi Fi Wireless Keypad X KeyFob one click access without a smartphone X Bridge remote operate the lock X X Warranty Poly Control ApS products are covered by a...

Page 16: ...support when they receive the following information about the unit 1 Serial number preferred MAC address or alias of the lock 2 Username used when registering installing the lock 3 Username used when...

Page 17: ...grated antennas and battery Connections Operational voltage supply voltage 4 x 3V DC 12V DC Standby time on the battery 450 days for V3 BTZB models Temperature range In active running mode 20 C to 40...

Page 18: ...roduct complies with Part 15 of the FCC rules and with Industry Canada license exempt standard s Operation is subject to the following two conditions 1 This device may not cause harmful interference a...

Page 19: ...ons de la FCC aux conditions pr vues pour un environnement non contr l Cet quipement doit tre install et fonctionner une distance minimale de 20 cm entre l appareil irradiant et votre corps Cet metteu...

Page 20: ...E The V3 BTZB product complies with the essential requirements of the RED Directive 2014 53 EU as stated by the EC Declaration of Conformity Certificates and Declaration of conformity DOC statements c...

Reviews: