background image

 
V3-BT 

 

 

 

Danalock V3-BT, Technical Manual v.1.5, May 2017   

Page 7 

Qualified Service 

Except for batteries, the V3-BT contains no user serviceable or replaceable parts. Non-
functioning units must be returned to an authorized service center for repair or 
replacement. 
 

Accessories and Batteries 

Use only approved accessories or batteries. Do not connect incompatible products. 
There is risk of explosion or fire if an incorrect type replacement battery contacts are 
shorted. Do not exceed the temperature ranges or other environmental conditions 
specified by the battery manufacturer. Dispose of used batteries according to the 
instructions provided with the batteries. 

Electro mechanical lock classification 

The following statements are related to the European norm EN 14846 for building 
hardware – electromechanically operated locks and striking plates. The V3-BT is classified 
according to this standard with the below declarations and precautions.  
 

Category of use 

The V3-BT can be used in areas with medium frequency of use by people with some 
incentive to exercise care but where there is some chance of misuse, e.g. internal office 
doors or internal residential doors. EN 14846 category of use classification grade=0. 
 

Durability, door mass and closing force and security (Physical attack) 

The type of door i.e. mass and closing force, durability for dead bolt or latch bolt 
operations and security for physical attacks are not applicable to V3-BT. The V3-BT lock is 
not in any case related to the door or striking plate already existing on the door where V3-
BT is mounted. It is however recommended to verify the operation of the V3-BT after 
mounting the product. Poly-Control ApS is not liable for the classification of the door and 
striking plate in relation to the mounting of the V3-BT. EN 14846 classifications N/A are 
used. 
 

Fire doors 

The V3-BT series is not approved for use with fire doors. EN 14846 suitability for use on 
fire/smoke doors classification grade=0. 
 

Safety 

No requirements are defined in the EN 14846 classification scheme. 
 

Water-Resistance 

The V3-BT series is not water-resistant. The lock must therefore be installed on the inside 
of the door where it is dry and not subjected to either water streams or submersion. EN 
14846 corrosion resistance classification grade=0. 
 

Security for electrical functions 

The V3-BT has no indications, sound alarms in case of a lock malfunction. EN 14846 
security – electrical function classification grade=0. 
 
 

 
 

 

Summary of Contents for V3-BT

Page 1: ...V3 BT Danalock V3 BT Technical Manual v 1 5 May 2017 Page 1 V3 BT Technical Manual Version 1 5 May 2017...

Page 2: ...vered standard content 11 Installing the unit 12 Practical installation advice 12 Functionality check 13 LED signals 13 Electro mechanical lock classification 14 Product family 15 Accessories 15 Warra...

Page 3: ...ol after sales service whose agreement is mandatory prior to any replacement Any shipping costs are at the Customer s expense The warranty does not apply to visible defects Also excluded are defects a...

Page 4: ...ERIALS AND ANY EMBEDDED SOFTWARE FIRMWARE AND UPDATES THERETO INCLUDING WITHOUT LIMITATION DAMAGES FOR LOSS OF BUSINESS PROFITS BUSINESS INTERRUPTION LOSS OF DATA OR ANY OTHER PECUNIARY LOSS REGARDLES...

Page 5: ...for radio terminal equipment supporting Bluetooth Low Energy 2400 2483 5 MHz ACMA AUS NZ The V3 BT product complies with the Australian New Zealand Radio communication Act for radio terminal equipment...

Page 6: ...site links to the My Danalock site from Poly Control ApS and it is found at my danalock com V3 BT devices can be integrated to the My Danalock site Safety first Simple Guidelines Please follow these...

Page 7: ...e doors or internal residential doors EN 14846 category of use classification grade 0 Durability door mass and closing force and security Physical attack The type of door i e mass and closing force du...

Page 8: ...is shielded from RF signals However certain electronic equipment may not be shielded against the RF signals generated by the V3 BT unit Pacemakers The Health Industry Manufacturers Association recomm...

Page 9: ...l powders and any other area where it would normally be advisable not to install the V3 BT Specific Human Absorption Rates SAR THE V3 BT UNIT IS NOT DESIGNED TO BE WORN ON A PERSON S BODY AS SUCH BODY...

Page 10: ...e Internet browsers you use and information about the way you use the Application Data retention policy managing your information We will retain User Provided data for as long as you use the Applicati...

Page 11: ...ng and disclosing information all of which activities will take place in Scandinavia Europe Middle East Asia and United States Contact us If you have any questions regarding privacy while using the Ap...

Page 12: ...he unit Practical installation advice Please follow the installation guide carefully It is available on the danalock site that is found at https guide danalock com Be aware that multiple installation...

Page 13: ...ion Constant red light till finishes Manually lock unlock when not calibrated Constant yellow light till finishes Lock has been latched successfully Constant yellow till fails then one red blink Lock...

Page 14: ...ence from other Bluetooth devices Apple products will typically be ranked higher than other Bluetooth devices Electro mechanical lock classification The V3 BT is categorized as an electro mechanical l...

Page 15: ...or the V3 series Description Bluetooth Wi Fi Wireless Keypad X KeyFob one click access without a smartphone X Bridge remote operate the lock X X Warranty Poly Control ApS products are covered by a lim...

Page 16: ...pport when they receive the following information about the unit 1 Serial number preferred MAC address or alias of the lock 2 Username used when registering installing the lock 3 Username used when ge...

Page 17: ...ated antennas and battery Connections Operational voltage supply voltage 4 x 3V DC 12V DC Standby time on the battery 450 days for V3 BT models Temperature range In active running mode 20 C to 40 C St...

Page 18: ...product complies with Part 15 of the FCC rules and with Industry Canada license exempt standard s Operation is subject to the following two conditions 1 This device may not cause harmful interference...

Page 19: ...ions de la FCC aux conditions pr vues pour un environnement non contr l Cet quipement doit tre install et fonctionner une distance minimale de 20 cm entre l appareil irradiant et votre corps Cet mette...

Page 20: ...The V3 BT product complies with the essential requirements of the RED Directive 2014 53 EU as stated by the EC Declaration of Conformity Certificates and Declaration of conformity DOC statements can...

Reviews: