7.0 POSSIBILITIES OF FAILURE
Error
Possible cause
Remedy
High pressure gauge deflection on
closing the HP pistol
-
safety valve incorrectly or defect
-
set safety valve to max. 10
above max. operating pressure
or renew
-
pressure regulating valve
switches incorrectly
-
check function of pressure
regulating valve, or renew
Operating pressure too low
-
incorrect high pressure nozzle
-
use nozzle acc. to type label
-
lime scale on heating coil
-
descale heating coil
-
pressure regulating valve set
too low
-
set pressure regulation valve to
required pressure
-
pressure regulating valve leaks
-
repair or renew pressure
regulating valve
Operating pressure too high
-
pressure gauge defect
-
renew
-
pressure regulating valve defect
-
renew
-
nozzle blocked
-
clean nozzle
Cleaning agents are not suctioned up
-
cleaning agent tank is empty -
fill
container
-
metering valve is not open
-
open metering valve
-
chemical tuber pipelines are
blocked
-
clean these tubes
-
water through flow too low
-
set pressure regulator higher
Heating does not reach temperature
-
heating oil tank is empty
-
fill heating oil tank
-
heating oil filter is blocked
-
clean heating oil filter, renew oil
pump
-
heating coil has lime scale
-
descale
-
combustion chamber is soothed
-
clean
Blower motor does not start up
-
blower motor fusing detective
-
renew fuses
-
over voltage release is released
by blower motor safety
thermostat
- reset
safety thermostat,
eliminate cause
Ignition for electrode not working
-
cable, ignition electrodes,
electrode plug or ignition
transformer defective
-
set ignition electrode according
to drawing, renew defective
parts
Oil misting
-
burner nozzle insufficient / worn
-
renew burner nozzle
-
oil pressure too low
-
set oil pressure to approx. 8,5
bar
No / too low oil pressure
-
pump / PVC coupling defective
-
renew
-
oil filter dirty or leaking
-
clean or seal
Solenoid valve does not open
-
temperature regulator set too
low
-
set temperature regulator
higher
-
water through flow too low
-
clean nozzle, increase pressure
-
flow monitor / pressure switch
defective
- renew
-
heating oil tank empty
-
fill heating oil