Dametric AB 

GIR-DM1 

GMS Industrial Router 

 

GIR-DM1 EN.docx 

Sept. 14, 2015 / BL 

Page 1 of 7 

 

 

 

 

 

GIR-DM1 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GMS Industrial 4G Router 

 

Description 

dametric

Summary of Contents for GIR-DM1

Page 1: ...Dametric AB GIR DM1 GMS Industrial Router GIR DM1 EN docx Sept 14 2015 BL Page 1 of 7 GIR DM1 GMS Industrial 4G Router Description dametric ...

Page 2: ...M1 is an industrial 4G router and the unit is used in RMS GMS systems for remote access functions The one and only task for the remote access system is for Dametric to supply support and service to the AGS system end user Files including logs alarms and settings can easily be retrieved by Dametric during normal working times Urgent 24 7 backup is also possible but this option has to be discussed a...

Page 3: ...S CHAP 2 dial filter for dial out linkloss detection failed login detection GRE Redundancy 2 dial out targets 2 OpenVPN server targets LAN Ports 2 x RJ45 switch Operating mode 10 100 MBit s for full half duplex Function Automatic recognition patch crossover cable automatic speed adjustment MDI MDI X Messages Hardware watchdog system messages via e mail SMS and SNMP traps SNMP V1 V2c V3 Additional ...

Page 4: ...orange WWAN link established Signal green SIM card no signal or logged out WWAN data traffic Field strength see Table 2 Status green VPN VPN connec tion estab lished red Status Initialization FW update fault Table 1 Meaning of display elements Blinking interval LED signal Quality Signal quality 900 ms on 100 ms off 20 31 very good 200 ms on 200 ms off 13 19 good 100 ms on 900 ms off 0 12 poor off ...

Page 5: ... meaning of the control elements 4 Connections 4 1 Front panel connections Use this socket for the GIR Antenna Ethernet cable to the switch Figure 2 Connections on the front panel of the device Position Description 1 Ethernet port LAN 1 RJ45 10 100 BT Connect this port to the GMS SW1 unit 2 Ethernet port LAN 2 RJ45 10 100 BT This port is normally not used 3 Cellular antenna connection SMA socket m...

Page 6: ...8 Description of the connections on the top of the device The reset input must be connected to ground GND to reset the device The functionality is identical to the reset key 5 Mounting Position the device at the DIN rail There are two snap in hooks at the upper and lower edge of the DIN rail groove Hook the upper one into place behind the upper edge of the DIN rail Lift the device perpendicular to...

Page 7: ...ide of the unit The standard IP address used is 192 169 11 50 mask 255 255 252 0 7 2 Internet router The unit has to be configured for the used SIM card settings Pin Enter the given pin from the Internet provider User name dametric Password service Access Port Name Enter name from provider 8 Valmet article number VAL0366871 9 Connection K1 1 24VDC Power supply K1 1 is the leftmost terminal K1 2 0V...