5.12 Analog input
The function is used for current signal, 4-20mA, for future definition.
AIN Off/On/On+Al
Off=disconnected, On=connected, On+Alarm=connected to the sum alarm function
AIN Al.lim.1 HH
Alarm limit 1, high-high.
AIN Al.lim.2 H
Alarm limit 2, high.
AIN Type
Measure function. Set 0.
AIN Range
Range.
AIN Zero calibr.
Zero calibration, se calibration manual for actual measure system.
AIN Span calibr.
Span calibration, se calibration manual for actual measure system.
5.13 FeedGuard func.
FG Result
Rotor travel distance at the latest FeedGuard release.
FG Type
Type, 0 = disconnect, 1 = connected and PLC controls rotor, 2 = connected and
BRM controls the rotor, 3 – not used.
FG Pist.length
Ventil-length (mm).
FG Safe dist.
Safe distance (mm).
FG Timeout
Time, the amount of time before the evaluation is done (s).
FG Pist. Delay
Delay time for the piston (s).
FG CMD speed
Rotor travel speed(mm/s).
FG Chk. max pos.
Maximum control limit. No check is done at a POM-value above this limit.
5.14 Rotor Move Ctrl.
The function is only valid and shown in a BRM-DM1.
RMC Function
Function, “Off” = disconnected. “Static op.” = static mode, the production position
is not changed in operation. ”Dynamic op.” = dynamic mode, the production
position is decreased automatic in operation when the gap is lowered (and enough
motor power under a minimum of time).
RMC Prod. pos.
Actual production position (mm).
RMC Start offset
Offset between the start position and the production position (mm).
RMC Set Prod.pos
Set a permanent production position. Set to a desired production position in static
mode or to 0.00 in dynamic mode (mm).
RMC Power limit
Minimum power to be able to decrease the production position in dynamic mode
(MW).
RMC Time limit
Minimum time to be able to decrease the production position in dynamic mode
(min)
RMC Min prod.pos
Minimum allowed production position (mm).
RMC Max prod.pos
Maximal allowed production position (mm).
5.15 Rotor Move Adj.
The function is only valid and shown in a BRM-DM1.
RMA Touchp.func.
Function. “Static” = static calibration med standstill refiner.
”Manual ” = manual calibration med rotating discs and the operator maneuvers the
plates completely. ”Automatic” = automatic calibration with rotating discs and the
operator maneuvers the plates to the touch point and BRM then maneuvers the plates
apart. ”PLC ctrl.” = The function is controlled by the DCS/PLC via the industrial
bus.
RMA Touchp.level
Minimum touch value (TVD) to determine the contact position (%).
RMA Touchp. Time
Minimum time as the TVD value has be over the limit to detect the contact position
(s).
RMA Touchp. pos.
Contact position (mm)
RMA Wear setting
Setting for measurement of the plate wear. 0 = disconnected, 1 = automatic
measurement, 2 = reset measurement relative the actual rotor position. Note - after a
reset (2), the previous value is restored.
RMA Wear offset
Rotor position value for the measurement of the plate wear (mm).
RMA Status
Status value for RMC/RMA-the function (described in a separate document).