INSTALLATION INSTRUCTIONS
MAINTENANCE
WARNING: SERVICING SHOULD BE CARRIED OUT ONLY BY AUTHORISED
PERSONNEL
During the guarantee period, in case of need all service intervention should be referred
back to the Service Department. Please note that intervention or repair by any
unauthorised personnel will invalidate such guarantee,
Before carrying out any maintenance, disconnect the appliance from the gas and electricity
supplies.
If a gas tap becomes stiff to operate, proceed as follows:
x
Remove the control knobs, pan supports, burners and hob fixing screws & clamps.
x
Remove the Hob from the worktop and remove any underside protective covers.
x
Disconnect the fixings holding the tap to the fascia panel, separate the assembly, then clean
the cone and seating with a cloth dampened with solvent.
x
Lightly smear the cone with high temperature grease, reassemble into position and rotate a
few times. Remove the cone again and remove any excess grease making sure that the gas
ducts are not obstructed with grease.
x
Carefully reassemble the components and check for gas soundness.
If it becomes necessary to replace the gas tap, proceed as follows:
x
Disconnect the appliance as described above.
x
Disconnect the gas pipe from the gas tap, disassemble from the gas rail by removing the
fixing screws.
x
When fitting a new tap, ensure that a new gasket is used.
x
Re-connect the gas tap, check for gas soundness and reassemble the hob.
TECHNICAL DATA
ELECTRICAL DETAILS
Rated Voltage
220-240V ac 50Hz
Supply Connection
10 Amp GPO
Power Input
0.008 to 0.02kW (depending on model)
Mains supply lead
3 x 0.75mm2 Type RR-F
HAR
!
marked
GAS DETAILS
Connection
½”
BSP
Type
Natural Gas 1.0 kPa – alternative ULPG 2.75 kPa
13