4M30 Camera User’s Manual
9
DALSA
03-32-10030-03
2
&DPHUD+DUGZDUH
,QWHUIDFH
2.1 Installation Overview
In order to set up your camera, you should take these initial steps:
1.
Power down all equipment.
2.
Following the manufacturer’s instructions, install the frame grabber (if applicable).
Be
sure to observe all static precautions.
3.
Install any necessary imaging software.
4.
Before connecting power to the camera, test all power supplies.
Ensure that all the correct
voltages are present at the camera end of the power cable
(Refer to the Camera Performance
Specifications on page 7). Power supplies must meet the requirements defined in
section 2.4 Power Input.
5.
Inspect all cables and connectors prior to installation. Do not use damaged cables or
connectors or the camera may be damaged.
6.
Connect data, serial interface, and power cables.
7.
After connecting cables, apply power to the camera. The POST (power on self test)
LED on the back of the camera should glow green after one second to indicate that
the camera is operating and ready to receive commands.
2.2 Input/Output
The camera provides 12-bit LVDS data and synchronization signals through the data
output connector. Camera functions such as integration time, camera gain and offset are
all controllable by the user via the RS232 serial port. The camera is capable of free running
operation or may be triggered externally via the input TRIGGER IN. TRIGGER OUT
allows the synchronization of shutters or illumination sources in free running or
externally triggered modes.
This installation
overview assumes you
have not installed any
system components yet.