26
•
Linea ML Multiline Monochrome / HDR CMOS Cameras
Selecting the Data Format
The camera can output data in the following formats:
Mono8
Mono12
Please refer to the frame grabber user’s documentation for further details on selection input and
output pixel formats.
Establishing Data Integrity
1.
Use the camera’s internal triggering. This allows for initial imaging with a static object and
no encoder input is required.
2.
Enable the camera to output a test pattern.
3.
Use a frame grabber CamExpert instance to capture, display and analyze the test pattern
image to verify the integrity of the connection. If the test pattern is not correct, check the
cable connections and the frame grabber setup.
4.
Disable the test pattern output.