Appendix B: Error Handling and Command List
Syntax
Command
Params
Description
wfc
write FPN
coefficients
Saves the FPN coefficients
wpc
write PRNU
coefficients
Saves the PRNU coefficients
wse
window start end
i i x1 y1
x2 y2
Sets the window start and stop pixels where:
i
is the window sequence id. It is always
0
in this camera.
i
is the number of windows to set. It is always
1
in this
camera.
x1
is window start corner value. Ranges from
0-1399
.
y1
is window start pixel number. Ranges from
0-1023
.
x2
is window end corner value. Ranges from
15-1399
.
y2
is window end pixel number . Ranges from
15-1023
.
wus
write user
settings
Write all of the user settings to non-volatile memory.