DF4910HD-DN | DDF4910HDV-DN-IM/-SM
www.dallmeier.com
30
Unscrew the 3 housing screws (
) using a T20 torx wrench and remove the
housing.
Mark the drill holes on the ceiling/wall using the 3 pre-drilled mounting holes of the
housing base (
At the marked locations, drill holes fitting the screws/anchors to be used.
Push anchors suitable for the ceiling/wall material into the drill holes.
Run the required cables suspended from the ceiling/wall through a PG16 cable gland.
Screw the PG16 cable gland in the appropriate thread of the housing base.
Mount the housing base with 3 screws to the ceiling/wall.
Housing base
Mounting screw (Ø 4 mm)
Thread for
PG16 cable gland
Anchor
Drill hole
Ceiling/Wall
Removable foam ring
Ambient light sensor
Fig. 6-7
Connect the required cables to the connectors of the camera module
(see
If necessary, connect a CVBS monitor to the video preview output (
).
If PoE (Power over Ethernet) is not available, first connect the camera to a suitable
power supply unit and then connect the power supply unit to the mains socket.
Carefully remove the foam ring with the ambient light sensor (
Be careful not to tear or bend the cables.
Align the camera with your scene using the 3-axis mount and set the focal length and
focus (loosen the corresponding locking screws before making any adjustments and
tighten them again when finished).
Attach the foam ring back onto the lens while ensuring that the ambient light sensor will
not be covered by the black inner dome cover.
Disconnect the CVBS monitor from the video preview output.
Attach the housing to the housing base and tighten the 3 housing screws (
) us
-
ing a T20 torx wrench.