background image

007531 | Rev. 2.0.0 | 2019-05-22

SM

DDF5(X)50HDV-DN

Commissioning

English

Summary of Contents for DDF5 50HDV-DN-SM Series

Page 1: ...007531 Rev 2 0 0 2019 05 22 SM DDF5 X 50HDV DN Commissioning English...

Page 2: ...iew California USA HDMI of HDMI Licensing LLC headquartered in Sunnyvale California USA JavaScript of Oracle Corporation and or its affiliates headquartered in Redwood Shores California USA microSDXC...

Page 3: ...nsportation and Packaging 13 Warranty 13 Appropriate Use 14 Operation 15 Approvals Certifications 16 6 Requirements 17 Ambient Conditions 17 Power Supply 18 7 Maintenance Inspection and Cleaning 21 8...

Page 4: ...e consists of various documents which are provided in printed and or digital form as for example via the website www dallmeier com Read the complete product documentation for the device carefully and...

Page 5: ...contractors of video security surveillance systems Other Applicable Documents Product Specification The product specification contains detailed technical data features and character istics of the dev...

Page 6: ...result in death or serious injury WARNING WARNING indicates a hazardous situation which if not avoided could result in death or serious injury CAUTION CAUTION indicates a hazardous situation which if...

Page 7: ...carry out instructions one after the other in the sequence described Expressions in quotation marks usually refer to individual components of the device housing parts mounting elements connections int...

Page 8: ...mpliance with the regulations of the DIN VDE 0701 0702 series of standards VDE 0701 0702 Inspection after repair modification of electrical appliances Periodic inspection on electrical appliances Gene...

Page 9: ...le via the website www dallmeier com Read the complete product documentation for the device carefully and thoroughly before using the device Always observe and follow the contained instructions notes...

Page 10: ...o avoid damage to the device by electrical surge during lightning storms all protective measures which are specified by the currently applicable DIN VDE and ISO standards and which provide for a stand...

Page 11: ...the device from the PoE enabled PSE port Contact the sales partner responsible for your area Opening the Device The device may only be opened by qualified personnel for commissioning inspection maint...

Page 12: ...the mounted housing base and the supporting structure ceiling or wall PG16 cable gland with standard sealing insert and sealing ring on connection thread Sealing insert with longitudinal cut for easy...

Page 13: ...sponsible for any damage resulting from unprofessional or improper transportation The device should only be shipped in the original packaging If the original packaging is no longer available ensure th...

Page 14: ...d by an external 24V DC power supply unit NOTICE Damage to the device caused by improper installation in outdoor environments The device is primarily designed for indoor use The installation of the de...

Page 15: ...lun must be installed if the BNC interface is permanently in use If the device or the cables connected to the device are located near sources with strong radiation the video image may be distorted The...

Page 16: ...ss A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environm...

Page 17: ...r com NOTICE Damage to the device due to unfavorable ambient conditions Unfavorable local conditions may shorten the lifetime of the device and may cause malfunctions or damages Do not install operate...

Page 18: ...improper earthing grounding Risk of death or serious injury The installation of the device and the connection of peripheral equipment may only be carried out by qualified personnel and in a voltage fr...

Page 19: ...supply unit Damage to the device or malfunctions due to the lack of or im proper grounding earthing Damage to electronic components caused by lightning strikes and over voltages electrical surges or m...

Page 20: ...eld between the contacts rises sharply when un mating the jack plug connection The more un mating cycles are carried out under PoE load the higher the loss of contact material due to metal evaporation...

Page 21: ...fety If it is necessary to clean the device observe the following notes NOTICE Damage to the surfaces of the device due to improper cleaning practices Clean the outside of the housing with a clean sof...

Page 22: ...itable sealing insert Drilling template marking tool e g awl and electric drill Three mounting screws 4mm and dowels suitable screwdriver WARNING Personal injury caused by falling device or collapsing...

Page 23: ...Rev 2 0 0 2019 Dallmeier www dallmeier com 23 Commissioning DDF5 X 50HDV DN SM Torx screwdriver with hollow point T20 H...

Page 24: ...eier www dallmeier com DDF5 X 50HDV DN SM Commissioning Loosen the three tamper resistant torx screws Torx TR 20 of the housing cover using a torx screwdriver with hollow point T20 H 3 Tamper resistan...

Page 25: ...Rev 2 0 0 2019 Dallmeier www dallmeier com 25 Commissioning DDF5 X 50HDV DN SM Remove the housing cover including the bubble from the housing base...

Page 26: ...2019 Dallmeier www dallmeier com DDF5 X 50HDV DN SM Commissioning Remove the threaded blanking plug of the side cable entry use a suitable coin or a large flat blade screwdriver Threaded blanking plug...

Page 27: ...Rev 2 0 0 2019 Dallmeier www dallmeier com 27 Commissioning DDF5 X 50HDV DN SM Securely seal the unused cable entry with the existing threaded blanking plug and the corresponding sealing ring...

Page 28: ...0 2019 Dallmeier www dallmeier com DDF5 X 50HDV DN SM Commissioning Remove the paper backing from the self adhesive rubber gasket Adhere the gasket to the bottom of the housing base Rubber gasket adhe...

Page 29: ...the chapter Interfaces on page 38 Route the required cables through the cable entry NOTICE Use the supplied PG16 cable gland or an equivalent type for optimum tightness Carry out the cabling PG16 Fitt...

Page 30: ...SM Commissioning NOTE Before mounting the housing base observe the intended camera viewing direction as well as the maximum permissible pan tilt and roll range of the 3 axis camera gimbal as shown on...

Page 31: ...rilling template At the marked locations drill holes fitting the used screws anchors Push anchors that are suitable for the ceiling wall type and construction material into the drill holes Mount the h...

Page 32: ...32 Rev 2 0 0 2019 Dallmeier www dallmeier com DDF5 X 50HDV DN SM Commissioning Maximum permissible pan tilt and roll range 45 Pan Max 90 Roll Max 180 Tilt Max 45 Knurled thumb screw roll axis...

Page 33: ...a corresponding PoE midspan device Establish an Ethernet connection to the camera with your web browser see chapter Connection First Time Access and Login on page 44 Log in to the camera s web based...

Page 34: ...50HDV DN SM Commissioning Attach the housing cover including the bubble back to the housing base NOTICE Make sure that the ambient light sensor is not covered by the black inner liner rotate the bubbl...

Page 35: ...sture dust and dirt After removing the housing cover the O ring may slip out of the provided groove left figure which will result in loss of tightness Before re attaching the housing cover make sure t...

Page 36: ...SM Commissioning Tighten the three tamper resistant torx screws Torx TR 20 of the housing cover using a torx screwdriver with hollow point T20 H NOTICE Observe the maximum permissible torque of 1 0Nm...

Page 37: ...Rev 2 0 0 2019 Dallmeier www dallmeier com 37 Commissioning DDF5 X 50HDV DN SM...

Page 38: ...38 Rev 2 0 0 2019 Dallmeier www dallmeier com DDF5 X 50HDV DN SM Commissioning 9 Interfaces...

Page 39: ...review output BNC CVBS 1 0Vp p 75 Memory card slot microSDXC compatible Video output HDMI Micro port Type D LAN PoE RJ45 jack PoE conformity IEEE 802 3af Audio Line OUT 3 5mm phone jack Power IN Weidm...

Page 40: ...level max 2 83Vp p Input impedance 29k Audio Line OUT stereo Output level at 10k load max 3 11Vp p Output impedance 320 Audio Line IN stereo Line OUT stereo Tip Left channel Left channel Ring Right c...

Page 41: ...er to comply with UL s requirements only use a UL certified Limited Power Source LPS power supply unit when powering the device by an exter nal DC power supply unit 24V DC Power IN Weidm ller male con...

Page 42: ...42 Rev 2 0 0 2019 Dallmeier www dallmeier com DDF5 X 50HDV DN SM Commissioning 11 Inserting a Memory Card microSDXC card optional...

Page 43: ...anty Damage to the device or memory card due to incorrect card insertion Make sure that the contacts of the used memory card are facing forward and down when inserting it into the memory card slot of...

Page 44: ...t to operate the device with Power over Ethernet a single port PoE injector is additionally required To configure the device the client PC must meet the following system require ments System Requireme...

Page 45: ...sure that your PC web browser can establish an Ethernet connection to the device if necessary contact your network administrator for more information and assistance Start the web browser Enter the IP...

Page 46: ...nt user name admin The default password is the complete serial number of the device The serial number is printed on the type plate of the device and can also be deter mined using the Dallmeier softwar...

Page 47: ...yed for authenticated and authorized users only The user name of the factory default administrator account is admin Enter your login credentials Click OK After the successful login the graphical user...

Page 48: ...hone jack for stereo TRS plug Input level max 2 83Vp p Input impedance 29k Audio Line OUT stereo 1 3 5mm phone jack for stereo TRS plug Output level at 10k load max 3 11Vp p Output impedance 320 Ether...

Page 49: ...af Power consumption DDF5250HDV DN SM Max 6W DDF5450HDV DN SM Max 12W Mechanical Data Gimbal 3 axis gimbal for manual adjustment pan tilt roll Bubble Clear with black inner liner Vandal resistant Yes...

Page 50: ...unt bracket Operating temperature 20 C to 50 C 4 F to 122 F Relative humidity 0 90 RH non condensing Approvals Certifications Type CE FCC RCM UL DIN 50130 4 compliant The technical product specificati...

Page 51: ...2 0 0 2019 Dallmeier www dallmeier com 51 Commissioning DDF5 X 50HDV DN SM 14 Dimensions 58 30 mm 2 30 113 83mm 4 48 133 75 mm 5 27 75 45 mm 2 97 151 93mm 5 98 2 5 3x 120 45mm 1 76 120mm 4 72 4 5mm 0...

Page 52: ...Dallmeier electronic GmbH Co KG Bahnhofstr 16 93047 Regensburg Germany Phone 49 941 8700 0 Fax 49 941 8700 180 www dallmeier com info dallmeier com...

Reviews: