background image

 

 

USER’S MANUAL                                  

 

                                   RELEASE 1.07 

VISUALISATION ALARMS 

This grinder allows you to see a series of information (alarms) about its functioning  
To see possible alarms ,press  P5 once from the main screen and then  P3 for three  times , then you will 
see :

 

 
 
 

If you press  P5 again, you can see one or more of the following alarms: 
 
01- LOSS OF  DATA – loss of the programming data in the memory . 
The grinder automatically recharges the  default data  ; this is not a blocking alarm, you will hear ten beep 
sounds .With  P5 you reset the alarm   
02-1-  GR.1 BLOCKED – block of grinder 1 ;   DL1 and  2 will blink , you will hear ten beep sounds .In this 
case the coffee supply is not counted.  
02-2-  GR.2 BLOCKED – block of grinder  2; DL3 and 4 will blink , you will hear ten beep sounds .In this 
case the coffee supply is not counted 
The reason for this alarm is that the absorption of the grinding motor is too high  or is blocked,  , with  P5 
you reset the alarm code but the  led corresponding to the group keep on blinking to show that the grinder 
is out of work . 
To start it again, switch off and on again the system 
03-1-  REGUL.  GRINDER1 IS BLOCKED  –  block of grinder 1 , DL1 and 2 will blink , you will hear ten 
beep sounds  
03-2-  REGUL.  GRINDER1 IS BLOCKED  –  block of grinder  2 ; DL3 and 4 will blink , you will hear ten 
beep sounds  
The reason for this alarm is that the absorption of the motoreductor of the grinding regulation is out of 
range , 60 m.A. in closure and  90 m.A. in opening  , with  P5 you  reset the alarm code but the led 
corresponding to the group keep on blinking to show that the grinder is out of work .  
To make everything strat again, switch off and on again the system 
04- SECURITY IS OPEN – this alarm only takes place if the grinder is opened while supplied with power , 
you will hear ten beep sounds. By pressing P5 you reset it and it is accepted only with a closed contact . 
05-1- TRIAK GR.1 IS FAULTY  -  Alarm of block of grinder  1 ;  DL1 and 2 will be blinking , you will hear 
ten beep sounds   
05-2- TRIAK GR.2 IS FAULTY -  Alarm of block of grinder  2  ;  DL3 and  4 will be blinking , you will hear 
ten beep sounds   
This alarm tells you that the  triak commanding the motor of the grinder is faulty. 
By pressing  P5 you  reset the alarm but the  led corresponding to the grinder keeps on blinking to show 
that this is out of work. 
The reason could be that the motor is not connected to the commanding system or the corresponding 
triak is faulty 
To start everything again , switch off and on again the system 
06-1- GR. 1 TIME OUT : this alarm blocks grinder  1 ; DL1 and 2 will be blinking, you will hear ten beep 
sounds . The alarm tells you that the commanding system does not see the functioning of the grinder-
regulating motor  or the position-sensor of the Hall effect is faulty .  
06-2- GR. 2 TIME OUT : this alarm blocks grinder  2 ; DL3 and 4 will be blinking, you will hear ten beep 
sounds .The alarm tells you that the commanding  system does not see the functioning of the grinder-
regulating motor  or the position-sensor of the Hall effect is faulty .

  

By pressing  P5 you reset the alarm but the led corresponding to the group keep on blinking to show that 
the group is faulty . 
To start everything again , switch off and on again the system

 

07- LOW POWER SUPPLY : this alarm  completely  blocks everything ;  DL1–2-3-4 will be   blinking , you 
will hear ten beep sounds .It tells you that the power supply is less than  35% of the nominal value . 
To start everything again , switch off and on again the system

 

 
 
 