2.2 Reliability test
TEST
CONDITION
METHOD
REMARK
1
High-Temperature Operation
T=40
℃
,
RH=35%RH
,
For
240Hr
IEC 60 068-2-2Bb
2
Low-Temperature Operation
T = 0
℃
for 240 hrs
IEC 60 068-2-2Ab
3
High-Temperature Storage
T=60
℃ RH=35% RH For 240Hr
Test in white pattern
IEC 60 068-2-2Bb
4
Low-Temperature Storage
T = -25
℃
for 240 hrs
Test in white pattern
IEC 60 068-2-2Ab
5
High Temperature, High-
Humidity Operation
T=40
℃
,
RH=80%RH
,
For
168Hr
IEC 60 068-2-3CA
6
High Temperature, High-
Humidity Storage
T=50
℃
,
RH=80%RH
,
For
240Hr
Test in white pattern
IEC 60 068-2-3CA
7
Temperature Cycle
-25
℃(30min)~ 60℃(30min)
,
50 Cycle
Test in white pattern
IEC 60 068-2-14NB
8
Package Vibration
1.04G,Frequency : 10~500Hz
Direction : X,Y,Z
Duration:1hours
in
each
direction
Full packed for
shipment
9
Package Drop Impact
Drop from height of 100 cm on
Concrete surface
Drop
sequence:1
corner,
3edges,
6face
One drop for each.
Full packed for
shipment
10
UV exposure
Resistance
765 W/
㎡
for 168hrs,40
℃
IEC 60068-2-5 Sa
11
Electrostatic
discharge
Machine model:
+/-250V,0Ω,200pF
IEC61000-4-2
Actual EMC level to be measured on customer application.
Note1
:
Stay white pattern for storage and non-operation test.
Note2
:
Operation is black/white/red pattern , hold time is 150S.
Note3
:
The function, appearance, opticals should meet the requirements of the test
before and after the test. Note4
:
Keep testing after 2 hours placing at 20
℃
-25
℃
.
GDEH075Z90
13
/
38
7.5 inch Series
www.good-display.com