When charging, remove the USB cover on the bottom of the
instrument and insert the USB charging cable (voltage DC5V,
current not greater than 2A) to recharge.

When charging the indicator light is red, the indicator light is
green, when the charging is finish.

7. Video output

When in use, remove the cover of the video interface at the
bottom of the instrument and insert the configured video cable,
which can be connected to the display or other long-distance
transmission.

8. Matters needing attention

Because uncooled infrared telescopes use very sensitive thermal
sensors, the lens must not be directly pointed at a strong source
of radiation (such as the sun, laser beam or reflection, etc.) under
any circumstances (turn on or off), or it will cause permanent
damage to uncooled infrared telescopes!

After laser pointer function is opened, do not irradiate the human
eye, so as not to cause injury!

When the instrument has been the automatic sleep state, it can
be awakened by any key.

Check the power when the instrument is first used. If necessary,
charge it for three hours and then use it. When USB charges,
please place the instrument at 40 C.

Please do not depart the device housing or refit it without
authorization. Maintenance matters can only be operated by the
company's authorized personnel.

Zhejiang Dali Technology Inc

www.dali-tech.com

Summary of Contents for S25 Series

Page 1: ...After turn on the device the indicator light will be green Short press after turned on to make the eyepiece dormancy and then press any key to wake up after dormancy 2 Zoom Button Short press it to relize X2 X3 X4 image digital zoom in it is real time zoom in when display of the target Press 3 seconds to freeze the current image and short press to thaw it 3 Brightness Button ...

Page 2: ... color mode White Hot mode Relatively high temperature is shown as white Black Hot Relatively high temperature is shown as black Red Hot Relatively high temperature is shown as red Pseudo color Relatively high temperature is shown as pseudo iron red Long press 3 second color palette button to open image menu function after that short press it to switch menu function tab while short press brightnes...

Page 3: ...splay the distance of the current image ruler after opening and the range can be adjusted by the Zoom Button or Brightness Button 6 WIFI switch function settings can be turned on AP or off N by press the Brightness Button cyclically After opening is displayed in the upper right corner of the image Note Opening WIFI for a long time will increase the power consumption of the instrument resulting in ...

Page 4: ...emperature point of the display screen after opening can be opened or closed by the Zoom Button or Brightness Button 9 Display dormant time settings 0 5 30 60 min factory default 0 Adjust by the Zoom Button or Brightness Button 10 Cursor settings can switch cursor type and cursor display position by the Zoom Button or Brightness Button Position adjustable it will be saved after adjustment 5 Visibi...

Page 5: ...ors the lens must not be directly pointed at a strong source of radiation such as the sun laser beam or reflection etc under any circumstances turn on or off or it will cause permanent damage to uncooled infrared telescopes After laser pointer function is opened do not irradiate the human eye so as not to cause injury When the instrument has been the automatic sleep state it can be awakened by any...