TECHNICAL NOTE 

INSTALLATION 

 

CAUTION: The product may only be connected and installed by a qualified electrician. All applicable regulations, legislation, and 
building  codes  must  be  observed.  Incorrect  installation  of  the  product  can  cause  irreparable  damage  to  the  product  and  the 
connected LEDs.  

 

Maintenance must be performed only by a qualified electrician in compliance with current regulations. 
Pay attention when connecting the LEDs: polarity reversal results in no light output and often damages the LEDs. 

 

The  product  is  designed  and  intended  to  operate  LED  loads  only.  Powering  non-LED  loads  may  push  the  product  outside  its 
specified design limits and is, therefore, not covered by any warranty. 
Operating conditions of the product may never exceed the specifications as per the product datasheet. 

 

The product must be installed inside a switchgear/control gear cabinet and/or junction box protection against overvoltage. 

 

The  product must  be  installed  in  a  vertical  or  horizontal  position  with  the  label/top  cover  facing  upwards  or  vertically.  Other 
positions are not permitted. The bottom position is not permitted (label/top cover facing down). 

 

Keep separated 230Vac (LV) circuits and not SELV circuit from safety extra low voltage (SELV) circuit and from any connection 
with this product. It is absolutely forbitten to connect, for any reason whatsoever, directly or indirectly, the 230Vac mains voltage 
to the product (terminal block of BUS included). 

 

The product must be dissipated correctly. 

 

The use of the product in harsh environments could limit the output power. 

 

For  built-in  components  inside luminaires,  the ta  ambient  temperature  range  is  a  guideline  given  for  the  optimum  operating 
environment. However, integrator must always ensure proper thermal management (i.e., correct mounting of the device, air flow 
etc.) so that the tc point temperature does not exceed the tc maximum limit in any circumstance. Reliable operation and lifetime 
are only guaranteed if the maximum tc point temperature is not exceeded under the conditions of use. 

POWER SUPPLY 

 

Only  use  SELV  power  supplies  with  limited  current  for  device  power  supply,  short  circuit  protection  and  the  power  must  be 
dimensioned correctly. 
In the case of power supplies equipped with ground terminals, it is mandatory to connect ALL protective  ground points (PE= 
Protection Earth) to a properly and certified protection earth. 

 

The connection cables between the very low voltage power source and the product must be properly dimensioned and must be 
insulated from any wiring or part at non-SELV voltage. Use double insulated cables. 

 

Dimension the power of the power supply in relation to the load connected to the device. In case the power supply is oversized 
compared to the maximum absorbed current, insert a protection against over-current between the power supply and the device. 

COMMAND 

 

The length of the cables connecting between the local commands (N.O. Push button, 0-10V, 1-10V, Potentiometer or other) and 
the product must be less than 10m. The cables must be properly dimensioned and must be insulated from any non-SELV wiring 
or voltage. It is recommended to use double insulated cables. 

 

ALL device and control signal connect to the local command (N.O. Push button or other) must be SELV type (the device connected 
must be SELV or supply SELV signal). 

OUTPUTS 

 

It is recommended a length of the connecting cables between the product and the LED module less than 10m. The cables must 
be properly dimensioned and must be insulated from any wiring or circuits at voltage not SELV. It is recommended to use double 
insulated cables. In case you want to use connecting cables between the product and the LED module greater than 10m, the 
installer  must  guarantee the correct  operation  of  the  system.  In  any  case,  the  connection  between  the  product  and  the  LED 
module must not exceed 30m. 

ONLY CASAMBI/BLUETTOTH PRODUCT 

 

WARNING: For optimal functionality of the Casambi signal, do not put the device into metal or aluminium boxes and do not shield 
the device. As any other Casambi product, should not be placed in a metal enclosure or next to large metal structures. Metal will 
effectively block all radio signals which are crucial to the operation of the product. 

WARNINGS 

 

To  guarantee the best  performances and the full  use of  functions, make sure to download  on  your  device the last release of 
CASAMBI APP. 

 

Whenever CASAMBI APP requires an upgrade of the profile installed in the LED Dimmers, follow the instruction to do it. This allows 
you to stay always up to date and benefit of new functions released. 

 

Functionality test are done on al
are asked to unpair it by following the instructions on CASAMBI APP and in paragraph 

 

Summary of Contents for LINE 5CV CASAMBI

Page 1: ...The dimmer LED is suitable for driving loads such as Strip LED and LED modules White monochromatic color Dynamic White RGB RGB W RGB WW and RGB TW at constant voltage You can connect a power supply a...

Page 2: ...ear dimming curve LINE TWxTW LINEAR LINE 4kHz 2700 6500K 25223 N 2 2 LED output channels two slides to dim the outputs and two slides to vary the Color Temperature PWM frequency 4000Hz Logarithmic dim...

Page 3: ...Supply voltage Min 10 8Vdc Max 52 8Vdc Output voltage Vin Current consumption Max 12A Output current2 max 12A Nominal power 12 Vdc 144W 24 Vdc 288W 48 Vdc 576W Power consumption while waiting for con...

Page 4: ...Connect the normally opened button to the INPUT 1 and INPUT 2 terminals with the symbol Be sure not to connect live parts to PUSH N O terminals Connect a 12 24 48 Vdc constant voltage SELV power supp...

Page 5: ...ly DALCNET S r l 36077 Altavilla Vicentina VI Italy Via Lago di Garda 22 Tel 39 0444 1836680 www dalcnet com info dalcnet com Rev 23 09 2022 Pag 5 10 CONNECTION SCHEME PROFILE TW TW TW TW CONNECTION S...

Page 6: ...ivo Made in Italy DALCNET S r l 36077 Altavilla Vicentina VI Italy Via Lago di Garda 22 Tel 39 0444 1836680 www dalcnet com info dalcnet com Rev 23 09 2022 Pag 6 10 CONNECTION SCHEME PROFILE RGB WW RG...

Page 7: ...s Press to switch between scenarios press and hold to adjust the brightness of the current scene For all other functions consult the documentation of the CASAMBI APP at https support casambi com suppo...

Page 8: ...and type of activity Flickering can affect a person s well being even if the fluctuations in luminance are beyond the threshold perceptible to the human eye The graph shows the phenomenon of Flickeri...

Page 9: ...PRELIMINARY Manuale Dispositivo Made in Italy DALCNET S r l 36077 Altavilla Vicentina VI Italy Via Lago di Garda 22 Tel 39 0444 1836680 www dalcnet com info dalcnet com Rev 23 09 2022 Pag 9 10 MECHAN...

Page 10: ...ort circuit protection and the power must be dimensioned correctly In the case of power supplies equipped with ground terminals it is mandatory to connect ALL protective ground points PE Protection Ea...

Reviews: