background image

DLC1248 

multi channel

 EASY RGB / EASY TW

Device Manual

                     

FW3.0+

 

Made in Italy

Rev. 2016-08-22

page  2/4

     

Reference

 

standards

EN 61347-1:2008+A1:2011+A2:2013

Lamp controlgear - Part 1: General and safety requirements

EN 61000-3-2:2014

Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions 
(equipment input current ≤ 16 A per phase) 

EN 61000-3-3:2013

Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage 
fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤
16 A per phase and not subject to conditional connection

EN 62384:2006+A1:2009

DC or AC supplied electronic control gear for LED modules - Performance requirements

EN 55015:2013+A1:2015

Limits and methods of measurement of radio disturbance characteristics of electrical lighting 
and similar equipment

EN 61547:2009

Equipment for general lighting purposes - EMC immunity requirements

EN 50581:2012 

Technical documentation for the assessment of electrical and electronic products with respect 
to the restriction of hazardous substances

    

Technical

 

Specifications

Variants

Constant current

Constant voltage

2 channels

3 channels

2 channels

3 channels

Supply voltage

DC min: 10.8 Vdc .. max: 52,8 Vdc

Input current

1) 

max 1,4A

 max 2,1A

max 3,2A

max 4,8A

Output voltage

min: Vin/4 max: Vin-0,9V

= Vin

Output current

1) 

 

350/500/700 mA/ch

Max 1.6 A/ch 

 1) 

max 1,4A

 max 2,1A

max 3,2A

max 4,8A

Nominal power 

1) 

@12V

8,4/12/16,8 Wmax

12,6/18/25,2 Wmax

38,4 Wmax

57,6Wmax

@24V

16,8/24/33,6 Wmax

25,2/36/50,4 Wmax

76,8 Wmax

115,2 Wmax

@48V

33,6/48/67,2 Wmax

50,4/72/100,8 Wmax

153,6 Wmax

230,4 Wmax

Thermal shutdown

150 °C

150 °C

D-PWM dimming frequency

250Hz

D-PWM resolution 

16 bit 

D-PWM range

0,1 – 100 %

Storage Temperature

min: -40 max: +60 °C

Ambient Temperature

 1) 

min: -10 max: +40 °C

Protection grade

IP20

Wiring

2.5mm

²

 solid - 1.5mm

²

 stranded - 30/12 AWG

Mechanical dimensions

44 x 44 x 25 mm

Packaging dimensions

68 x 56 x 35 mm

Weight

40g

    

 1) 

maximum value, dependent on the ventilation conditions

 

LED DRIVERS

DALCNET S.r.l.

Registered office: via Meucci, 35 - 36040 Brendola (VI) - Italy 

Headquarters: via Meucci, 35 - 36040 Brendola (VI) - Italy 

Tel. + 39 0444 1836680/1867452 Fax. + 39 0444 1867453 

VAT: IT-04023100235 

[email protected] www.dalcnet.com

Summary of Contents for DLC1248 Series

Page 1: ... 500mA 2 N O push button DLC1248 2CC700 12 48V DC 2 x 700mA 2 N O push button DLC1248 3CC350 12 48V DC 3 x 350mA 3 N O push button DLC1248 3CC500 12 48V DC 3 x 500mA 3 N O push button DLC1248 3CC700 12 48V DC 3 x 700mA 3 N O push button Constant voltage variants common anode AppIication 2 channels output tunable white Application 3 channels output RGB colour CODE Supply voltage Output Channels Com...

Page 2: ...ic products with respect to the restriction of hazardous substances Technical Specifications Variants Constant current Constant voltage 2 channels 3 channels 2 channels 3 channels Supply voltage DC min 10 8 Vdc max 52 8 Vdc Input current1 max 1 4A max 2 1A max 3 2A max 4 8A Output voltage min Vin 4 max Vin 0 9V Vin Output current1 350 500 700 mA ch Max 1 6 A ch 1 max 1 4A max 2 1A max 3 2A max 4 8...

Page 3: ...tton connect leds DLC1248 2CC350 DLC1248 3CC350 DLC1248 2CC500 DLC1248 3CC500 DLC1248 2CC700 DLC1248 3CC700 DLC1248 2CV DLC1248 3CV LED DRIVERS DALCNET S r l Registered office via Meucci 35 36040 Brendola VI Italy Headquarters via Meucci 35 36040 Brendola VI Italy Tel 39 0444 1836680 1867452 Fax 39 0444 1867453 VAT IT 04023100235 info dalcnet com www dalcnet com ...

Page 4: ... or indirectly the 230V mains voltage to the bus or to other parts of the circuit Power Supply For the power supply use only a SELV power supplies with limited current short circuit protection and the power must be dimensioned correctly In case of using power supply with ground terminals all points of the protective earth PE Protection Earth must be connected to a valid and certified protection ea...