DGM02
Device Manual
Made in Italy
DALCNET S.r.l.
36077 Altavilla Vicentina (VI)
–
Italy
Via Lago di Garda, 22
Tel. +39 0444 1836680
–
Rev.
06/12/2022 -
Pag.
9/32
WEB INTERFACE
For supervision and configuration, the Gateway provides a web interface accessible via a browser at the IP address of the device
(default IP 192.168.1.4).
By clicking on the top menu, you can view the device settings (accessible only to Admin users):
Channels
: in this page it is possible to configure the dimming values of the channels
with the relative fader (not visible if in DALI CONFIG mode);
Bus Configuration:
in this page it is possible to configure the settings for each single
physical bus on the DGM02;
Dali global settings:
in this page it is possible to configure the settings for the DALI
bus (modifiable only if in DALI CONFIG mode);
DALI Config:
on this page you can configure the DALI devices, address them and
assign membership to groups (not visible if in DALI CONTROLLER mode);
DALI controller:
on this page it is only possible to view the addressed DALI devices
and their belonging to the groups (not visible if in DALI CONFIG mode);
DMX512 Global Settings:
in this page it is possible to configure the DMX512 timing
settings (not visible if in DALI CONFIG mode or RS485 Bus not enabled);
RS485:
on this page you can configure the settings for the sending speed of the
RS485 packet (not visible if in DALI CONFIG mode or RS485 Bus not enabled);
MODBUS Master:
on this page you can configure the settings for sending the master
MODBUS RTU packet (not visible if in DALI CONFIG mode or if the master MODBUS
RTU BUS is not enabled);
MODBUS Slave:
on this page you can configure the settings for sending the MODBUS
RTU slave packet (not visible if in DALI CONFIG mode or if the MODBUS RTU slave
BUS is not enabled);
Network:
on this page you can configure the settings to change and manage the IP
address, the Netmask and view the MAC Address;
Login Settings:
on this page it is possible to configure the settings for modifying and
managing the LOGIN USER and PASSWORD;
sACN:
on this page you can configure the settings for enabling or disabling the
protocol;
Telnet:
on this page you can configure the settings for enabling or disabling the
protocol and sending times;
ARTNet:
on this page you can configure the settings for enabling or disabling the
protocol;
MODBUS TCP Slave:
on this page you can configure the settings for enabling or
disabling the protocol;
Firmware Update:
on this page it is possible to configure how the device Firmware
is updated;
Log:
the product logs are stored on this page;
Log Configuration
: on this page you can configure the settings for managing the
LOGs.