B
C
45
ENGLISH
THIS VENTILATION SYSTEM IS TOTALLY INDEPENDENT FROM THE AIR INTAKE FOR COMBUSTION!!
The following measurements must be respected:
LOWER PART (COLD AIR INLET) WITH TOTAL MINIMUM SURFACE 550 CM².
UPPER PART (HOT AIR OUTLET) WITH TOTAL MINIMUM SURFACE 550 CM².
For correct functioning of the insert, during construction of the flue
the measurements between the insert and internal walls of the flue
must be respected (figure below).
From the clearance measurements of the stove given in the technical
features, it is necessary to consider at least 50 mm of air in the upper
part and on the 2 sides.
Minimum 5 cm
THE INSERT MUST LIE AT LEAST 1 CM ABOVE THE FIRE SURFACE IN COVERING MARBLE.
It is just as important to guarantee the minimum distance of 5 cm
on both sides as shown in the figures above.
Reference A
Hot convection air
The heat accumulated inside the
covering must be vented to prevent excessive overheating of
the insert.
Reference B
Forced ventilation
The tangential fan distributes the heat developed by the insert
into the environment.
Reference C
Air inlet from the room:
To allow air recirculation an air inlet point must be envisioned,
which is preferably positioned in the lower part of the structure in
order to encourage convection. The air must be withdrawn from
the machine's working environment.
THE FLUE OUTLET PIPE MUST ALWAYS MAINTAIN A MINIMUM DISTANCE OF 50 MM FROM INFLAMMABLE PARTS.
IMPORTANT: ALL OPENINGS MADE FOR PROPER AIR RECIRCULATION MUST BE MADE INACCESSIBLE BY MEANS OF
APPROPRIATE PROTECTIVE GRILLES OR MESHES, ENSURING THE MINIMUM PASSAGE OF AIR REQUIRED.
Summary of Contents for INSERTO 700 ELITE CRYSTAL
Page 2: ...2 Applicare etichetta dati technici ...
Page 32: ...A B C E E E F F D F D D 32 ITALIANO ...
Page 62: ...A B C E E E F F D F D D 62 ENGLISH ...
Page 92: ...A B C E E E F F D F D D 92 FRANCAIS ...
Page 122: ...A B C E E E F F D F D D 122 DEUTSCH ...
Page 152: ...A B C E E E F F D F D D 152 ESPAÑOL ...
Page 158: ...158 ...
Page 159: ...159 ...