| eNgLIsh
AsPIrATION FAuLT
Fumes motor fault
Contact after-sales centre
FuMes PrObe
Fumes probe failure.
Contact after-sales centre
hOT FuMes
High flue gas temperature
Check pellet feed (see “Pellet feed adjustment”). If
the problem cannot be solved, contact an authorised
technician.
CLeAN CheCK uP 1 - 2
(1 = sTArT-uP PhAse)
(2= WOrK PhAse)
The door is not closed correctly.
The ash drawer is not closed correctly.
The combustion chamber is dirty.
The flue exhaust pipe is blocked.
Check hermetic door closure.
Check hermetic closure of the ash drawer.
Check cleanliness of the fumes pipe, of the sensor in the
primary air channel and the combustion chamber.
NO
IgNITION
The pellet feed-box is empty.
Pellet feed calibration inadequate.
Check for the presence of pellets in the feed-box.
Adjust pellet flow (see “Pellet feed adjustment”).
Check the procedures described in the “Ignition” chapter.
NO IgNITION
bLACK OuT
No current during the ignition phase.
Take the stove to OFF conditions using key 1 and repeat
the procedure described in the "Ignition" chapter.
NO PeLLeTs
The pellet feed-box is empty.
No pellet feed.
The motor reducer does not feed pellets.
Check for the presence of pellets in the feed-box.
Adjust the pellet flow (see “Pellet feed adjustment”).
DePr ALArM
The door is not closed correctly.
The ash drawer is not closed correctly.
The combustion chamber is dirty.
The flue exhaust pipe is blocked
Check hermetic door closure.
Check hermetic closure of the ash drawer.
Check cleanliness of the fumes pipe and the combustion
chamber.
DebIMeTer
FAuLT
Flow sensor faulty.
Sensor disconnected
Contact after-sales centre
h20 OVerTeMP
The water in the stove has exceeded 95°C.
Possible air in the system.
Lack of adequate circulation.
Lack of or inadequate safety zone.
Possible circulator anomaly.
Contact after-sales centre
TrAPDOOr FAuLTy
The automatic cleaning of the burn pot
is blocked.
Contact after-sales centre
MINIMuM
Pressure ALArM
The system pressure read by the pressure
switch is too low.
Possible presence of air in the system.
Possible lack of water or leaks due to
anomalies in some system component.
Contact after-sales centre
h2O PrObe
ALArM
H2O probe failure
Contact after-sales centre
MAx h2O
Pressure ALArM
The pressure of the water has exceeded
the max threshold
Check that the expansion vessels are not damaged or
under-dimensioned
Check that the cold system is loaded at the correct pressure
ALArMs
When the boiler goes into alarm mode, the screen becomes red and does not accept commands outside the display. When the screen turns green,
“alarms memorY” will be displayed with the type of alarm and the boiler can respond to external controls. If the alarm can be solved by the user,
once this has been performed the boiler can be re-ignited by pressing key 1. In the event of a more complex alarm, contact the after-sales assistance.
29 / 09 /2012
18 : 56
STBY
SABATO
-
+
29 / 09 /2012
18 : 56
STBY
SABATO
-
+
ACTIVE ALARM
ALARM MEMORy
"ALARM TyPE"