DD5075265
Rev 00
3 June 2022
NPN-X200/X400 Series Speed Frame Substructure & Panel Quick Guide
Page 2 of 4
201 Daktronics Drive
Brookings, SD 57006-5128
www.daktronics.com/support
800.325.8766
Install Next Adjacent Frame in First Row
1.
Position the adjacent frame in the row next to the installed frame.
2.
Install the supplied stitch bolts (HC-1842). Refer to
.
Figure 5:
Install Stitch Bolts
3.
Ensure the alignment tabs are flush
and even with each other. Refer to
lock the tabs into place.
4.
Cut the zip ties and verify that the
bolt assemblies slide freely.
5.
Slide the bolt assemblies to the
nearest stud lines.
6.
Use a 4' level on top of the frame to
level the frame while positioning it.
7.
Repeat
Steps 5–7
in
8.
Repeat
Steps 1–7
until the first row is
fully installed.
9.
Use a string line across the installed bottom row and adjust the
Z-position of the frames so the frame faces are all aligned to the string.
Verify the frame faces are level vertically as they are adjusted for the
string line.
Install Remaining Frames
1.
Position the left frame in the next row on top of the first installed frame.
Ensure the alignment tabs are flush and properly aligned. The mid
verticals set the X- and Y-axis positions of the frame.
2.
Install the supplied stitch bolts across the horizontal seam and tighten to
lock the frame into place. Refer to
Figure 6:
Ensure Alignment Tabs Are
Flush & Even
Figure 7:
Install Stitch Bolts across Horizontal Seam
Figure 8:
Ensure Alignment Tabs Are
Flush & Even
3.
Cut the zip ties, allowing the bolt assemblies to slide along the track.
4.
Slide the bolt assemblies to the nearest stud locations.
5.
Install TEK screws and brace plates, but do not tighten all the way.
Leave the TEK screws approximately
1
/
8
" from tightened down.
6.
Install the remaining frames while leaving the frames slightly loose from
the wall. Refer to
Figure 9:
Lock X & Y Position
Figure 10:
Install Remaining Frames
Plumb/Level Entire Display
1.
Identify the wall high spot. Use a level on the face of the frame column
while adjusting the Z-position of the frame column. If a high spot cannot
be identified, start with the center-most frame column in the display.
2.
Use the frame alignment tabs closest to the display corners and secure
a string line in an X pattern. Refer to
Figure 11:
Secure String Line
3.
Identify frame high points along the string line. Adjust the Z-position
toward the wall at the high points if the frames were not previously
Z-adjusted. If the high-point frame was previously Z-adjusted, adjust the
surrounding frames away from the wall to make the display face level
and plumb.
4.
Tighten down the TEK screws to lock the frame Z-positions into place.
5.
Adjust the frame Z-positions until the faces are aligned to the string and
the frame faces are plumb and level to each other.