Fuelight
TM
FL-3000 and FL-4500 Petroleum
Display Installation Quick Guide
DD2238842
Rev 08
06 February 2019
201 Daktronics Drive
Brookings, SD 57006-5128
www.daktronics.com/support
800.325.8766
Page 2 of 4
3.
Connect supply power ground wire to the grounding stud. Refer to
.
Note:
Verify the power supply ground wire is connected to the
grounding stud.
Display Interconnections
Signal travels from the host driver jack J9 to additional display drivers
through the Line-to-Line cable. Line-to-line connections are made using
jacks J9 and J10 on the driver.
The preferred cable routing has signal leaving each driver from jack J9
and entering the next driver on jack J10
Each time you connect the line-to-line cable to J9, you must also
connect the drain wire to the upper-left stud that holds the driver in
place.
1.
Use provided knockouts on the back of the display for signal
entrance and exit. Refer to
.
2.
Install the provided bushing at the
knockout location.
3.
Connect the provided line-to-line
driver jack J9. The host driver can be
identified by having the
communication option attached to
jack J16.
4.
Place the drain wire of the line-to-
line cable on the upper-left stud that
holds the driver in place. Refer to
5.
Place the 6-32 nut on the stud and
tighten it with a 5/16” nut driver. Refer
Figure 4:
Power Connection With
Grounding Stud
Line 2
Line 3
Line 1
2
3
1
Signal Wire
Figure 5:
Line-to-Line
Details
Figure 6:
Line-to-Line Cable
Figure 7:
Installed Line-to-Line
Cable with Drain Wire
Figure 8:
Installed Drain Wire