background image

Fuelight

TM

 FL-3000 and FL-4500 Petroleum 

Display Installation Quick Guide

DD2238842
Rev 08
06 February 2019

201 Daktronics Drive

Brookings, SD 57006-5128

www.daktronics.com/support

800.325.8766

Page 2 of 4

3. 

Connect supply power ground wire to the grounding stud. Refer to 

Figure 4

.

Note: 

Verify the power supply ground wire is connected to the 

grounding stud.

Display Interconnections

Signal travels from the host driver jack J9 to additional display drivers 

through the Line-to-Line cable. Line-to-line connections are made using 

jacks J9 and J10 on the driver.
The preferred cable routing has signal leaving each driver from jack J9 

and entering the next driver on jack J10 

Each time you connect the line-to-line cable to J9, you must also 

connect the drain wire to the upper-left stud that holds the driver in 

place.
1. 

Use provided knockouts on the back of the display for signal 

entrance and exit. Refer to 

Figure 5

.

2. 

Install the provided bushing at the 

knockout location. 

3. 

Connect the provided line-to-line 

cable, shown in 

Figure 6

, to host 

driver jack J9. The host driver can be 

identified by having the 

communication option attached to 

jack J16. 

4. 

Place the drain wire of the line-to-

line cable on the upper-left stud that 

holds the driver in place. Refer to 

Figure 7

.

5. 

Place the 6-32 nut on the stud and 

tighten it with a 5/16” nut driver. Refer 

to 

Figure 8

.

Figure 4: 

Power Connection With 

Grounding Stud

Line 2

Line 3

Line 1

2

3

1

Signal Wire

Figure 5: 

Line-to-Line 

Details

Figure 6: 

Line-to-Line Cable

Figure 7: 

Installed Line-to-Line 

Cable with Drain Wire

Figure 8: 

Installed Drain Wire

Reviews: