Waterproofing criteria 

IP 69 

Dimensions 

53x58 (L) mm (Body Only) 

Environmental Rating 

IP69+ 

Operating Temp 

-45°F~150°F (-42°C~66°C) 

Network Connector 

RJ45, 10/100M 

Control 

Onvif Compatible (Profile S) 

Power 

12V 800mA (10 - 15 V Min/Max) 
Note: for POE use only 12V 

 

 

XI.

 

 WARNINGS 

 

When selecting a camera system from Dakota Micro, be sure to utilize the appropriate system for your use. InnoPro, 
AgCam and EnduraCam cameras are designed for high impact, moisture, vibration, and a variety of other rough 
conditions. OverView cameras and kit components are designed for light use, low vibration, and low moisture. OverView 
equipment is not warranted when used in situations outside of the above-mentioned parameters.  We always request 
that customers keep in mind that our less expensive OverView product line is cheaper because it does not feature the 
reliability and durability of our InnoPro, AgCam and EnduraCam lines. The warranty available on these products reflects 
that durability. 

 

To avoid electrical shock and maintain optimal functionality, do not open the enclosures. High voltage may be present 
and there are no user serviceable parts inside. All warranties will be void should any enclosures be tampered with in any 
way. 

 

Do not use any harsh chemical solvents, cleaning agents or corrosive detergent to clean away dirt on the surface of the 
screen or lens.  

 

On AgCam and EnduraCam products, the photo-chromic camera lenses have been made impact-resistant and have been 
drop-ball tested according to Sec. 3.84,21 CRF BUT ARE NOT UNBREAKABLE. Because they have been hardened 
chemically, they show no stress pattern. Inspect your lenses frequently. Chipped or scratched surfaces will reduce 
protection. Such lenses should be replaced only by the manufacturer. 

 

Power to cameras is not interrupted by turning off monitor; 12v power source must be terminated when not in use to 
avoid battery drain. To avoid this problem be sure when hard wiring a unit, use a fused circuit. 

 

Do not use your Dakota Micro camera system for anything other than legal surveillance and observation uses. Dakota 
Micro, Inc. is not liable for any illegal or nefarious usage. 

 

 

Summary of Contents for InnoPro DMIP-CO4

Page 1: ...II Camera Mounting 3 IV Viewing InnoPro via RJ45 3 4 A Hookup your Components 3 B Install Your Software 3 4 V InnoPro Software General Controls 4 VI InnoPro Software Camera Specific Controls 5 VII Inn...

Page 2: ...degree horizontal field of view at 4MP Minimum focal distance of 3 inches Available with optional onboard memory of 16GB or 64GB 64GB only available on C series allows for local storage of recorded v...

Page 3: ...d a camera to the app to find your InnoPro camera Dakota Micro does not provide support for this function If you are not an advanced network user consult a network provider for assistance Default Inno...

Page 4: ...will automatically determine any required setting adjustments If you see all green checks next to your network settings all you need to do is name your camera 8 Click Add Camera The camera name will a...

Page 5: ...by right clicking on live camera image or selecting Camera drop down Icon Title Function Full screen Brings selected camera to full screen Click on the icon to return to minimized view Multi window vi...

Page 6: ...appears in system tray Allows users the option to auto toggle video stream to be mainstream when displayed in full screen but substream when in windowed mode Exit Allows users to shut down program Vie...

Page 7: ...screen video view Zoom Out Allow users to zoom out of video when zoomed in Toggle Zoom Move Tool Allows users to zoom in to a specific section of video Change Camera Name Allows users to change camer...

Page 8: ...section of this manual b Record Schedule 1 Click on the schedule times you would like for recording to occur and choose your settings c Stream Access 1 Camera Name If no camera name is entered the cam...

Page 9: ...n Screen Display ii Overlap Information Shows bitrate and or resolution near camera title iii Time Position iv Time Format v Title Position vi Title Message Video Encode both Mainstream and Substream...

Page 10: ...a Storage Setting b Motion Alarm Record c Motion Alarm Snap d Link Down Record e Link Down Capture f Schedule Record Storage Device Information iv Alarm Motion Alarm a Motion Alarm b Sensitivity c Al...

Page 11: ...s for download of the video that you have selected on by clicking on it to select Delete button will allows for deletion of the video that you have selected by clicking on it to select IMPORANT NOTE A...

Page 12: ...mum close focus of 3 changing the resolution will change the viewing angle of the camera 1080P 56 true horizontal field of view 3MP 61 true horizontal field of view 3MP Wide 70 true horizontal field o...

Page 13: ...e on these products reflects that durability To avoid electrical shock and maintain optimal functionality do not open the enclosures High voltage may be present and there are no user serviceable parts...

Page 14: ...rmation RA Number provided by Dakota Micro Technical Support Shipping and associated costs to ship product to DM factory to be borne by the customer unless otherwise specified 5 Customer should mail p...

Page 15: ...User Manual DMIP ___ Author CNR Revised By MES Revision Date 03 24 21 Page 15 of 16 THIS PAGE INTENTIONALLY LEFT BLANK...

Page 16: ...ights under this limited warranty the purchaser should follow the steps set forth in the complete Dakota Micro Product Warranty Repair Process listed on page 15 section XIII and provide proof of purch...

Reviews: