background image

CP-3211_CP-4221 QIG_Mar27_2014 

 

 

 

 

 

Quasar CP-3211/CP-4221 HD PTZ Dome Camera Quick Installation Guide

 

Initial Configuration 

1.

 

Prepare the camera: 

Remove the camera’s protective packaging. 

2.

 

Attach an Ethernet cable: 

a.

 

Connect one end of a Cat 5 Ethernet cable to the Ethernet port on the top of the camera, and the other end to a Power 
Sourcing Equipment (PSE) device, such as a PoE+/Ultra PoE switch.  

b.

 

Verify that the LEDs on the cable’s RJ45 connector are green (indicating a good network connection) and flashing yellow                                                                         
when there is network activity. 

NOTE:

 The camera IP Address and the subnet mask IP Address are automatically supplied by the DHCP server.  In case the DHCP server 

is not available, the camera’s default IP address is 192.168.0.250. 

TIP:

 A camera setup adapter, such as Veracity Pinpoint, can be used to connect a laptop directly to the camera using PoE+. 

NOTE

: If you are using IE 9 as your web browser, work in Compatibility Mode. 

3.

 

Set the camera’s IP address: 

a.

 

Open the DNA application. Select the unit requiring IP assignment. See figure below. 

b.

 

To open the DNA 

Assign IP

 screen, do one of the following: 

 

 Select the unit, right-click the mouse, and select the 

Assign IP

 option 

 

 Select the 

Assign IP

 

 button from the toolbar 

 

c.

 

If your network does not have a DHCP server, enter the IP Address, Mask (Netmask) and Gateway values in the dialog box 
displayed below. 

d.

 

Click 

Update

 and wait for 

 

OK

 status to be displayed. The IP value has been assigned. 

 

4.

 

Disconnect the cable: 

a.

 

Disconnect the Ethernet cable. 

b.

 

If you are using a power supply, turn it off and disconnect it. The camera is ready for mounting in a site installation. 

c.

 

Refer to the camera’s user manual for mounting instructions. 

Site Installation 

WARNING:

  The Quasar CP series camera must be kept in a clean and dry indoor environment or in the protective outdoor mounting kit 

supplied with the outdoor model. The camera should be kept dry and free from water condensation, dust, dirt, and smoke. 

1.

 

Mount the camera: 

Install one of the following mounts, according to the camera’s User and Installation Guide: Quasar HD PTZ Hard Ceiling Mount 
(supplied with indoor models): Recessed Mount; Standard Pendant Mount (Pendant Mount compatibility is standard on outdoor 
models); Compact Pendant Mount; Wall Box Mount; or Corner Mount.  

2.

 

Attach cables: 

Thread cables through the installed mounting device and connect to the camera’s back plate. 

a.

 

Plug the Cat 5 cable into the camera’s Ethernet port. 

b.

 

Plug the other end of the cable into an IEEE 802.3at PoE+ switch (Ultra PoE switch for -HPoE models). If operating the heater 
for outdoor models, or if the network does not support PoE+/Ultra PoE, also plug in a properly rated 24VAC cable into the 
camera’s power connector.  

NOTE

: If using the outdoor HPoE model, the heater can be operated while using an Ultra PoE injector. 

c.

 

If applicable, connect the Alarm In, Alarm Out, Audio In and Audio Out terminal blocks to external devices.  

d.

 

Attach and fix the camera to the mounting device. 

 

 

Indoor Camera 

Outdoor Camera 

 

Callout 

Description 

Callout 

Description 

RJ45 Connector 

Factory Default Reset Button 

Audio I/O Connector 

Power Connector 

Alarm I/O Connector 

MicroSD Card Slot 

PTZ Pin Assignments 

Power, Audio and Alarm connector pin-outs are shown below: 

  

Power Connector 

 

Audio Connector 

 

 

Pin No. 

Definition 

 

 

Pin No. 

Definition 

AC 24- 

LINE_OUT 

FG 

GND 

AC 24+ 

LINE_IN 

 

Alarm I/O Connector 

 

 

Pin No. 

Definition 

Pin No. 

Definition 

ALARM_OUT_NO_1 

ALARM_OUT_COM_2 

ALARM_OUT_NC_1 

GND 

ALARM_OUT_COM_1 

ALARM_IN_4 

GND 

10 

ALARM_IN_3 

ALARM_OUT_NO_2 

11 

ALARM_IN_2 

ALARM_OUT_NC_2 

12 

ALARM_IN_1 

Reviews: