page 4
MAN#650265
Follow the steps below for gauge setup:
1. Press and hold the switch while turning the key on. (If calibrating speed press and hold switch while starting engine.)
2. Release switch. Gauge will scroll through the main menu options.
3. When the desired option is displayed, press and release the switch to enter menu option.
4. Gauge will scroll through submenu options. Press and release the switch to enter submenu option.
5. In submenu option, press and release the switch to change setting. Press and hold switch to save setting.
6. Select “done” from submenu to return to main menu.
7. Select “done” from main menu to leave setup menu. Setup can be left at anytime by turning off key
SETUP MENU GUIDE:
Release switch to enter setup menu
Information menu
Displays software version
Current software version
Displays current speed cal value
Current speed cal value
Returns to main menu
Speed gauge menu
Select unit for speed
Toggle between MPH and km/h (select unit to use for calibration)
Auto calibrate speedometer to a marked mile or kilometer
Displays
on speed and speed pulses in odometer
Press switch to save value and leave setup
Adjust speed cal while driving
Each press of switch toggles direction of adjustment, value saved after 8 sec no switch
SERV
Sets value of service odometer set when service odometer is reset
(
)
Turns off the count down service odometer (default)
(
)
Sets service to 500 mi or 800 km when resetting service odometer.
….
Service point can be set in 500 mi (800km) increments.
(
)
Sets service to 7500 mi or 12000 km when resetting service odometer.
Returns to main menu
Tachometer gauge menu
Sets tachometer input type
number of cylinders from 1-15 (default 12 for stock tach input)
SERV
Sets service hour value used when resetting count down service hour meter
Service hour meter disabled (default)
Minimum service hour set point
…
Service hour reset point can be set in 10 hr increments
Maximum service hour set point
Returns to main menu
Gauge option menu
VOLTS
Set high voltage warning point (default 15.4V)
VOLTS
Set low voltage warning point (default 11.1 V)
OIL
Set low oil pressure warning point (default 9 PSI)
TEMP
Set high water temp warning point and set temperature unit (default 230F)
(
)
Select temp unit, press switch to change, hold switch to save
TEMP
Select high warning, press switch to change, hold switch to save
Returns to main menu
SETUP MENU GUIDE (continued):
Option menu