Setting the warning limit and sender type: 

The low and high warning limits can be set to different values, also the front bag, rear 

bag, and tank warnings can each be set differently.  The TNK terminal is used for setting the 
warning limit.  The TNK terminal should be unhooked from and sender and a wire should be 
attached which can be momentarily grounded.  The procedure for setting the warning limit is 
as follows: 
1.  Ground the TNK terminal while you turn the key on.  The display should light up and show 

“WARNING SET MODE”. 

2.  Release the TNK terminal.  The display should show “SENDER  xxx-xxx” where is xxx is 

150 for the 150 psi senders and 400 for 400 psi senders.  The first number is the bag 
sender setting and the second is the tank sender setting. 

3.  Each time the TNK terminal is momentarily grounded the type will change. 
4.  When the desired sender type is shown hold the TNK terminal grounded. 
5.  The display will now show “FRNT HI WARN xxx” where xxx is the current high pressure 

warning point.  Release the TNK terminal.   

6.  Each time the TNK terminal is momentarily grounded the high warning point will increase.   
7.  When the desired high warning point is displayed hold the TNK terminal grounded.  The 

display will change to “FRNT LO WARN  xx” where xx is the current low pressure warning 
point. 

8.  Release the TNK terminal.  Use the TNK wire to increment through the low warning 

values until the desired value is shown. 

9.  Hold the TNK terminal grounded.  The display will change to “REAR HI WARN xxx” where 

xxx is the current high pressure warning point. 

10. Release the TNK terminal.  Each time the TNK terminal is momentarily grounded the high 

warning point will increase.   

11. When the desired high warning point is displayed hold the TNK terminal grounded.  The 

display will change to “REAR LO WARN  xx” where xx is the current low pressure warning 
point. 

12. Release the TNK terminal.  Use the TNK wire to increment through the low warning 

values until the desired value is shown. 

13. Hold the TNK terminal grounded.  The display will change to “TANK HI WARN xxx” where 

xxx is the current high pressure warning point. 

14. Release the TNK terminal.  Use the TNK wire to increment through the high warning 

values until the desired value is shown. 

15. Hold the TNK terminal grounded.  The display will change to “TANK LO WARN  xx” where 

xx is the current low pressure warning point. 

16. Hold the TNK terminal grounded.  The display will show “FINISHED”. 
17. Release the TNK terminal.  The gauge will restart with the new warning points. 

 

WARNING! 

CONNECTING A HIGH CURRENT 

INDICATOR DIRECTLY TO THE 

WARNING OUTPUT WILL DAMAGE 

THE UNIT. 