Using external warning indicators: 

The yellow wire provides a ground trigger whenever the gauge is outside 

its set limits.  Low current indicators (less than 1/4 A) can be activated directly by 
connecting their power wire to 12 volts and connecting their ground wire to the 
yellow output wire.  Many gauges can share the same indicator by connecting 
their yellow warning wires together.  In this way, when any one or more gauges 
are outside their limits the warning indicator will be activated. 

For higher current buzzers or lights, a relay will need to be used to switch 

the indicator on.  Dakota Digital’s RLY-1 30A relay may be used for this.  One of 
the coil wires should be connected to 12 volts and the other coil wire connected 
to the yellow warning wire.  When the gauge is outside its limits, the relay will 
turn on.  The relay contact wires can be used to switch the higher current. 
 

WARNING! 

CONNECTING A HIGH CURRENT 

INDICATOR DIRECTLY TO THE 

WARNING OUTPUT WILL DAMAGE 

THE UNIT. 

 
 
 
 
 

Wiring: 

 
BLACK 

connect to a good ground point in the vehicle. 

RED   

connect to an accessory terminal from your fuse block. 

GRAY  

 

connect to the oil temperature sender. 

BLUE   

connect to the tail light circuit. 

YELLOW 

(optional) connect to warning indicator. 

 

Summary of Contents for Odyssey ODY-07-1

Page 1: ...e warning points Microprocessor stabilized readings Quick Start feature to provide accurate readings quickly after being powered up Night dimming with lens label lighting High Visibility VFD display for sunlight readability The oil temperature gauge will read the temperature that the engine oil is currently at The oil temperature gauge will operate and read correctly between the temperature range ...

Page 2: ...set to different values Once it has been set it is stored internally so that the gauge will retain the values even when the gauge does not have any power This value can be set and reset as many times as desired The procedure for setting the warning limit is as follows 1 Make sure the key is off so the gauge is not powered 2 Press and hold the SET button This is located behind the hole located on t...

Page 3: ...uzzers or lights a relay will need to be used to switch the indicator on Dakota Digital s RLY 1 30A relay may be used for this One of the coil wires should be connected to 12 volts and the other coil wire connected to the yellow warning wire When the gauge is outside its limits the relay will turn on The relay contact wires can be used to switch the higher current WARNING CONNECTING A HIGH CURRENT...

Page 4: ... 9 16 x 1 11 16 It should be inserted into the opening from the front and the U clamp will be installed from the back Tighten the two nuts on the U clamp so that the gauge is secure Figure 2 shows the required cut out for the gauge Figure 3 shows how the gauge mounts ...

Page 5: ...rn gauge for repair contact factory Gauge lights up but does Loose connection on red Reconnect red wire not read correctly power wire Poor ground connection Move ground to different location Incorrect sender type Make sure sender has been replaced with the correct type SEN 04 x Gauge is not calibrated Gauge must be recalibrated correctly contact factory Gauge flashes constantly Warning limits are ...

Page 6: ...ddress phone number and specification of defects transportation prepaid to the factory This Warranty is valid for the original purchaser only and may not be transferred This warranty does not cover nor extend to damage to vehicle electrical system This Warranty does not apply to any product or part thereof which in the opinion of the Company has been damaged through alteration improper installatio...

Reviews: