background image

MAN#650111 rev. A 

 

ODYR/SLX-20 AMP CURRENT GAUGE 

 
Wiring: 

PWR 

 

connect to fused, switched, 12 volt power (an accessory terminal will work for this) 

DIM 

 

 

connect to the tail light circuit (when terminal has +12V, gauge will dim) 

SND 

 

 

connect to the Output terminal from current sensor.  

GND/Gauge case          - 

connect to a main ground location.  The sensor and gauge should have a common 
ground wire to ensure accurate readings.   

Earlier style sensors have the following color code:  RED 

– power, GREEN – output, BLACK & WHITE – ground. 

 

Mounting: 

The Series II gauge requires a round hole 2-1/16

” in diameter.  It should be inserted into the opening from the front 

and the U-clamp will be installed from the back.  Tighten the two nuts on the U-clamp so that the gauge is secure.  Gauge 
depth to the back of the case is 1”.  Gauge depth including the mounting studs is 1-7/8”. 

 
Display update choices: 

FSt (fast) 

The display is updated 10 times per second. 

(default setting)

 

SLO (average)  - 

The display is averaged over one second. 

HLd (Peak Hold)- 

The display uses the fast rate and the highest current reading will be held for up to ½ second. 

 

 

The amp current gauge will operate and read correctly from 3 

– 250 Amperes. The sender has an opening which the 

cable to be monitored must pass through. An arrow on the sensor points towards the end of the power wire leading to 
the load.   

 

The sender must be Dakota Digital part SEN-20-3.

  Sending units from other manufacturers will cause incorrect 

readings.  The output of the sensor is linear with 0V at 0A, 5V at 250A, and 10V at 500A. 

 
Setting the update speed: 
 

The SND terminal is used to enter and change the warning settings.  You will need a wire connected to the SND 

terminal that can be connected to power while you watch the gauge.  The sender must be disconnected from the gauge 
while this is done.  The headlights should be off or the DIM terminal unhooked so that it does not interfere with the setup. 

1.  To enter the set mode, turn the key on with the SND wire powered.  The gauge will disp

lay “SEt”.  

2. 

Disconnect the SND wire.  The gauge will display “SPd”.  (If you wait too long the gauge will exit the setup routine 
and you will need to repeat step #1). 

3.  Power the SND wire.  The gauge will display the current update speed (SLO, FSt, or HLd). 
4.  Disconnect the SND wire. 
5.  Each time you momentarily power the SND wire the speed setting will change. 
6.  When the desired update speed is displayed, keep the SND wire powered for about 2 seconds.  The gauge will 

display “--”. 

7. 

Turn the key off.

 

Reviews: