SPEED CALIBRATION 

The speed calibration is not required unless you have changed out the stock transmission, pulley, or tires. 

ADJvST 

ADJvST 

ADJvST 

ADJvST 

Adjust 

 

Press and release the switch until “

AdJvSt

” is displayed, then press and hold the switch until “ 

-

 ” is displayed. 

 

Release the switch.  The display will show “

fast

“ or “

sLOWX

”.  Fast will allow you to increase the speedometer reading, slow will 

allow you to decrease the speedometer reading. 

 

Press and release the switch to change, press and hold the switch to continue.  The display will change to “

CL

” and a number from 

0.75 to 1.25.  This is the calibration ratio that is applied to the reading that the ECM is providing.  1.10 will be 10% faster, 0.90 will 
be 10% slower. 

      Actual speed 
-----------------------------  x   current cal ratio (1.00 by default)      =    new cal ratio speedometer reading 

 

Press and release the switch to change the cal ratio.  When the desired cal ratio is shown, press and hold the switch to save it.

    

    

vNIT 

vNIT 

vNIT 

vNIT 

Speed unit 

 

Press and release the switch until “

vnit

” is displayed, then press and hold the switch until “ 

-

 ” is displayed. 

 

Release the switch.  The display will light up the current speed unit (MPH or km/h).   

 

Press and hold the switch to keep the current unit or press and release the switch to change the unit.   

 

Press and hold the switch until “ 

-

 ” is displayed to save the setting.

 

 

S SET 

S SET 

S SET 

S SET 

Miles to Next Service setup 

The service mileage is a countdown mile meter.  The service mile display can be disabled or can be set to count down from 

500 – 7500 miles.  If the service mileage is enabled and it gets to 0 miles it will display “

S -DvE

” each time the key is turned on.  If the 

push button switch is pressed and held while “

S -dve

“ or “

S

” and a mileage is displayed, the service miles will be reset to your preset 

value.   

 

Press and release the switch until “

S set

” is displayed, then press and hold the switch until “ – ” is displayed. 

 

Release the switch.  The current setting will be displayed,  “

OFF

” or a mileage from 

500

 - 

7500

 

Press and release the switch until the desired setting is displayed. 

 

Press and hold the switch until “ 

-

 ” is displayed to save the setting.

 

 

PERF 

PERF 

PERF 

PERF 

Performance menu setup 

The performance readings can be turned on or off.  When they are turned off the odometer display will only toggle through the 

mileage readings. 

 

Press and release the switch until “

PErF

” is displayed, then press and hold the switch until “ 

-

 ” is displayed. 

 

Release the switch.  The current setting will be displayed (

on

 or 

oFF

). 

 

Press and release the switch until the desired setting is displayed. 

 

Press and hold the switch until “ 

-

 ” is displayed to save the setting.

 

    
nIgHt

nIgHt

nIgHt

nIgHt

 Night Dimming 

Your display system has a dimming feature that dims the display intensity automatically at night.  Normally the system is at full 

brightness for daytime viewing.  To have the system at full brightness all of the time, go into the setup menu as described above and 
select “

ngt

” (night).  Press and release the function switch to select “

OFF

” instead of “

on

”.   Press and hold the function switch to save 

the new setting. 

 

Press and release the switch until “

nIgHt

” is displayed, then press and hold the switch until “ – ” is displayed. 

 

Release the switch.  The current setting will be displayed. (

ON

OFF

). 

 

Press and release the switch until the desired setting is displayed. 

 

Press and hold the switch until “ 

-

 ” is displayed to save the setting. 

 

W

WW

WX

XX

XArn

Arn

Arn

Arn

 

RPM

 Rpm warning setup 

The rpm warning/shift point can be adjusted from 2000 – 7500. 

 

Press and release the switch until “

WXArn

 

RPM

” is displayed, then press and hold the switch until “ 

-

 ” is displayed. 

 

Release the switch.  The current warning point will be displayed on the bar graph. 

 

Press and release the switch until the desired setting is displayed. 

 

Press and hold the switch until “ 

-

 ” is displayed to save the setting.

 

 

W

WW

WX

XX

XArn

Arn

Arn

Arn

 

V

 Voltage warning setup 

 

Press and release the switch until “

WXArn

 V

” is displayed, then press and hold the switch until “ 

-

 ” is displayed. 

 

Release the switch.  The current warning point will be displayed (

9

.

0

 – 

12

.

1

). 

 

Press and release the switch until the desired setting is displayed. 

 

Press and hold the switch until “ 

-

 ” is displayed to save the setting.

 

 