background image

CAD-03 Kit GSM
Auto Dialer

Owner’s Manual

CAD-03 Kit Manual.indd   1

10/15/2009   10:16:01 AM

Summary of Contents for CAD-03 Kit GSM

Page 1: ...CAD 03 Kit GSM Auto Dialer Owner s Manual CAD 03 Kit Manual indd 1 10 15 2009 10 16 01 AM ...

Page 2: ...e two separate dialer alarms alarm and panic select up to 9 32 digit user programmable phone numbers for each alarm different 10 second recordable message for each alarm arm disarm using keypad or remote keyfob wireless panic built in tamper switch built in terminal block for alarm and siren connection DC adaptor with rechargeable battery back up programmable as silent alarm dialer only or audible...

Page 3: ... detection area when the system is armed The PIR Sensor is set to Alarm 2 so take this into account when you are programming your voice messages Opening the PIR Sensor to access dipswitches and battery connector 1 Slide the PIR Sensor off the bracket use the bracket as a template for mounting 2 Using a small standard screwdriver press the release clip on the bottom of the PIR Sensor 3 Separate the...

Page 4: ...F Shock Sensor set to OFF Note On the PIR and shock sensor off is in the down position On the Dialer off is in the up position 2 Install battery in PIR sensor Figure 1 2 and mount at desired location Note recommended to replace batteries every 6 months 3 Remove the battery insulator by pulling black tab from the back of the RF Shock Sensor Unclip the bracket from the back and mount in desired loca...

Page 5: ...tery included into the auto dialer Use a small Phillips screwdriver to remove screw above battery cover Figure 2 3 Remove cover by sliding downwards Plug in battery pack making sure not to force onto pins incorrectly Put battery pack in space provided close battery cover and replace the screw Mount Auto Dialer in desired location Note if tamper switch is not completely compressed Auto Dialer will ...

Page 6: ...ur digit user password code factory default is 1234 2 Press RECORD 3 Press 1 to save as the message for alarm 1 or 2 to save as the message for alarm 2 4 Press ENTER to start recording your 10 second message 5 Press ENTER to stop the recording early or wait for the 10 seconds to end Quick guide Press 1 2 3 4 RECORD 1 ENTER record message now How to play back the message Press 1 2 3 4 PLAY 1 ENTER ...

Page 7: ...e Auto Dialer to call once it has been activated maximum 9 different numbers Quick guide Press 1 2 3 4 PROGRAM 3 ENTER 1 ENTER Telephone ENTER How to set Auto Dialer to send Voice or SMS message 1 Key in the four digit user password code factory default 1234 2 Press PROGRAM 0 ENTER 1 ENTER 3 Press N N 0 for voice message 1 for SMS message Press ESC Quick guide Press 1 2 3 4 PROGRAM 0 ENTER 1 N ESC...

Page 8: ...larm 2 Press ENTER 4 Press N N 1 for first phone number 2 for second phone number etc Press ENTER 5 Repeat the process to designate any other numbers to each alarm Quick guide Press 1 2 3 4 PROGRAM 6 ENTER X ENTER N ENTER How to change the user password code factory default is 1234 1 Key in the four digit user password code factory default 1234 2 Press PASSWORD 3 The LCD will change to n p 4 Key i...

Page 9: ... ENTER 3 Press Time Time 1 for one minute 2 for 2 minutes etc up to 99 minutes Press ENTER Quick guide Press 1 2 3 4 PROGRAM 2 ENTER Time ENTER How to set Entry Exit Delay times default both delay set at 30 seconds The entry exit times are the times the Auto Dialer gives you to enter exit the area covered by the system before it arms alarms These are pre set to 30 seconds You can also change the t...

Page 10: ...Tamper Function factory setting Tamper ON 1 Key in the four digit user password code factory default 1234 2 Press PROGRAM 8 ENTER 3 Press N N 0 without tamper function 1 with tamper function Press ENTER Quick guide Press 1 2 3 4 PROGRAM 8 ENTER N ENTER How to program monthly self test Most SIM cards will be disabled if they are inactive for too long To stop this from happening enable the self test...

Page 11: ...elay time you have set has expired Quick guide Press 1 2 3 4 ENTER How to disarm the Alarm System Turn Dialer OFF To disarm the Alarm System or to stop the Dialer from dialing out after either the tamper switch if connected and active or a alarm input has been activated key in the four digit user password code followed by ESC The Auto Dialer will revert to the OFF mode and must be re set to the ON...

Page 12: ...uence and the alarm if programmed will stop If the local alarm has been programmed as active then pressing the key will stop the dialing sequence but the alarm will continue to sound until timed out In both cases the Auto Dialer will remain ON waiting for any further alarm Quick guide Answer the phone and press or to stop dialing sequence How to change the back up battery Important It is recommend...

Page 13: ...ice provider AT T T Mobile RebelFone O2 Wireless etc with questions reguarding SIM cards Services may be limited by your local provider Please contact them reguarding local limitations How to reset the Auto Dialer Inside the battery compartment Remove the power supply and the Auto Dialer from the wall Remove the 7 2V battery Then remove the SIM card Inside the battery compartment is a switch Move ...

Page 14: ...t us You can reach us by phone at 605 356 2772 from 8 30 AM to 5 00 PM Monday through Friday Central Standard Time We will be happy to answer your ques tions and help you in any way we can WARRANTY Dakota Alert warrants this product to be free of defects in material and workman ship for a period of one year from the date of purchase This warranty does not cover damage resulting from accident abuse...

Page 15: ... are dialed 1234 PROGRAM 3 ENTER N ESC 4 Entry Delay N 0 for instant 3 for 30 secs 6 for 60 secs 9 for 90 secs 1234 PROGRAM 5 ENTER N ENTER 5 Exit Time N 0 for instant 3 for 30 secs 6 for 60 secs 1234 PROGRAM 4 ENTER N ENTER 6 Designate phone numbers to alarms X 1 for Alarm 1 2 for Alarm 2 N 1 9 order in which numbers are dialed 1234 PROGRAM 6 ENTER X ENTER N ENTER 7 Entrance Exit Delay Sound N 1 ...

Page 16: ...Dakota Alert Inc 32556 E Main Street P0 Box 130 Elk Point SD 57025 Phone 605 356 2772 Fax 605 356 3662 Web www dakotaalert com CAD 03 Kit Manual indd 16 10 15 2009 10 16 02 AM ...