32
Functional description and specifications
Warning
Disconnect the tool from the air source before making any adjustments, changing accessories or storing
the tool. Such precautionary safety measures reduce the risk of unintentional tool operation.
Fig.1
Specifications
Normal Operating Pressure: 70-115PSI(0.5-0.8M Pa)
Maintenance: Oiling
Av. air requirement: 30.8 L/min
Firing Mode: Sequential Fire/Contact fire
Fastener Size Range: 2"- 3-1/2"(50-90mm)
Fastener Type Paper collation
XI3490 driver 34°clipped D head framing
nails(Paper collation)