Do not exceed maximum recommended air pressure
marked on the tool.
Verify prior to using the tool that the air
source has been adjusted within the rated air-pressure
rang. Be sure the air pressure gauge is operating properly
and check it at least twice a day. Tools operated in excess
of their maximum pressure rating may operate abnormally
or burst resulting in personal injury.
To connect the tool to the compressor only use pneumatic
air hoses that meet the following criteria:
Minimum hose pressure rating, 600PSI.
Minimum hose inner diameter, 1/4 in.
Maximum hose length, 100 ft.
Connect the air supply:
Snap the air hose onto the quick connector.
Check for air leakage. If leakage is noted, stop using the
tool immediately and perform by qualified repair
personnel.
Be sure the air pressure gauge is operating properly and
check it at least twice a day.
TOOL TESTING
OPERATORS AND OTHERS IN WORK AREA MUST WEAR
SAFETY GLASSES WITH SIDE SHIELDS WHICH CONFORMS
TO ANSI Z87.1 SPECIFICATIONS.
NEVER USE TOOL UNLESS SAFETY IS OPERATING
PROPERLY.
1.
2.
3.
WARNING
WARNING
DANGER
The machine employs a preventive mechanism for
unloaded operation.
The machine enters a state where the push lever stopper
runs into the upper part of the push lever and the push
lever cannot be pushed up. This takes place when the
magazine is not loaded with nails or when the remaining
number of nails becomes less than 4-7 (This differs by the
type of nail).
Push lever
stopper
Push lever
FIG. 5
Use caution not to throw the push lever tip onto wood and
while the push lever stopper is in the upper part of the push
lever.
CAUTION
Before actually beginning the nailing work, test the tool by
using the checklist below. Conduct the tests in the
following order.
Disconnect air hose from tool. Remove all nails from tool.
1.
This s a state where the push lever stopper rad into
the upper part of this push lever and the push lever
cannot be pusher up.
i
FIG. 6
THE NO-MAR TIP AND TRIGGER MUST MOVE
SMOOTHLY.
Trigger
No-Mar tip
FIG. 7
Adjust the air pressure to 180psi. Connect the air hose.
Do not load any nails in the tool. Set the switching device
to the downward position.
2.
THE TOOL MUST NOT LEAK AIR.
5
Do not connect
air hose.
FIG. 4
FIG. 8
Push lever
stopper
Push lever
Keep the nail feeder
pulled backward
Downward
position
Switch Button