background image

05

Do  not  exceed  maximum  recommended  air  pressure 
marked on the tool. Verify prior to using the tool that the air 
source  has  been  adjusted  within  the  rated  air-pressure 
range. Be sure the air pressure gauge is operating properly 
and check it at least twice a day. Tools operated in excess of 
their maximum pressure rating may operate abnormally or 
burst resulting in personal injury.

To connect the tool to the compressor only use pneumatic 
air hoses that meet the following criteria:

CONNECT THE AIR SUPPLY:

Snap the air hose onto the quick connector.
Check for air leakage. If leakage is noted, stop using the 
tool  and  perform  repair  by  qualified  personnel 
immediately .
Be sure the air pressure gauge is operating properly and 
check it at least twice a day.

Minimum hose pressure rating, 200PSI.
Minimum hose inner diameter, 1/4 in.
Maximum hose length, 100 ft.

1.
2.
3.

NAIL LOADING

FIG. 4

WARNING

Connecting  the  air  supply  after loading  nails  reduces  the 
risk of unintentionally driving a nail and injuring yourself or 
someone else.

Connect air supply.
Pull  the  pusher  back  to  the  end  of  magazine.  Lock 
pusher  in  the  place  by  lock  button.  Then  pull  the 
magazine side shelter back.
Place full clip of desired fasteners into magazine from 
the  side.  Up  to  100  cleat  nails  can  be  loaded  into 
magazine. Be noted that, when holding the L cleat nails, 

the  side  with  the  L  head  should  be  in  the  left  of  the 
magazine side shelter. Press the lock button, then the 
pusher set back to make the magazine side shelter down 
back.

1.
2.

3.

FIG. 6

FIG. 7

LOADING CLEAT NAILS

LOADING STAPLES

Connect air supply.
Pull  the  pusher  back  to  the  end  of  magazine.  Lock 
pusher  in  the  place  by  lock  button.  Then  pull  the 
magazine side shelter back.
Place a full  clip of 1/2"Crown Staples  in the magazine 
from the top. Up to 2 x 45pcs to 2 x 60pcs can be loaded 
into the tool. 

Press the lock button, then the pusher sets back to make 
the magazine side shelter down back.

1.
2.

3.

4.

Pusher

Lock button

Staple

Magazine 

side shelter

T cleat

Lock button

Pusher

Magazine 

side shelter

L cleat

FIG. 5

CONNECTING AIR SUPPLY

Never use oxygen or other bottled gases as a power source. 
Explosion may occur. Combustible gases and other bottled 
gases are dangerous and may cause the tool to explode.

Never connect the tool to an air source that is capable of 
producing  air  pressure  exceeding  200PSI.  Excessive 
pressure can cause abnormal operation or cause the tool to 
burst, resulting in personal injury.

WARNING

WARNING

WARNING

www.chinaairtool.com

MODEL:06A-618BR

Summary of Contents for 06A-618BR

Page 1: ...jiang Prov 317500 P R China www chinaairtool com MODEL 06A 618BR USERS MANUAL WARNING SAVE THIS MANUAL FOR FUTURE REFERENCE 3 IN 1 FLOORING NAILER Failure to follow warnings could result in DEATH OR SERIOUS INJURY TAIZHOU DAJIANG IND CO LTD DAJ M0502 V2 ...

Page 2: ...RATING THE TOOL COLD WEATHER OPERATION SPECIFICATION FEATURES WORK AREA PERSONAL SAFETY TOOL USE AND CARE SERVICE AIR SOURCE JAM CLEARING CLEANING STORAGE HOOKUP INSTRUCTIONS FOR TOOL TO AIR SUPPLY IMPORTANT INFORMATION EXPLANATION OF THE NAILING ACTION GENERAL SAFETY RULES DESCRIPTION AND SPECIFICATION ASSEMBLY INSTALLATION OPERATION MAINTENANCE RECOMMENDED HOOKUP TROUBLE SOLVING www chinaairtool...

Page 3: ... horseplay with the tool Respect the tool as a working implement Doing so may cause malfunction and personal injuries Read manual carefully learn its applications and limitations as well as the specific potentialhazards related to this tool USE ONLY FASTENERS THAT ARE RECOMMENDED FOR YOUR MODELS CHECK FOR MISALIGNMENT OR BINDING OF MOVING PARTS BREAKAGE OF PARTS AND ANY OTHERS CONDITION THAT MAY A...

Page 4: ...ACTURER FOR THE SPECIFIC TOOL MODEL USE OF UNAUTHORIZED PARTS OR FAILURE TO FOLLOW MAINTENANCE INSTRUCTIONS MAY CREATE A RISK OF INJURY USE ONLY THE LUBRICANTS SUPPLIED WITH THE TOOL OR SPECIFIED BY THE MANUFACTUR TOOL SERVICE MUST BE PERFORMED ONLY BY QUALIFIED REPAIR PERSONNEL PLACE TOOL PROPERLY ON WORKPIECE DO NOT USE THE TOOL AS A HAMMER KEEP ALL SCREWS AND COVERS TIGHT IN PLACE KEEP FACE HAN...

Page 5: ...Pressure Magazine Capacity Fastener Size Range Length 20 1 510mm Height 22 8 580mm Width 3 54 90mm 11 2Ibs 5 1kg 70 115psi 5 8bar T cleat 100 pcs L cleat 100pcs Staple 120pcs T cleat 1 1 2 2 38 50mm L cleat 1 1 2 2 38 50mm Staple 1 1 2 2 38 50mm Air Cap Hand Grip Air Plug Magazine Pusher Body Hammer Cap Arm Shoe Foot Plate L cleats T cleats 38mm 45mm 50mm 1 1 2 1 3 4 2 16Ga 16Ga 38mm 45mm 50mm 1 1...

Page 6: ...h each tool are one copy of these Operating Safety Instructions Keep this publications for future reference Install a filter regulator lubricator unit and moisture trap on your air delivery system per the manufacturer s instructions for these devices Additionally install a pressure gauge as close as practical to the tool preferably within 10 feet Select hoses with a minimum inner diameter of 1 4 i...

Page 7: ...zine side shelter back Place full clip of desired fasteners into magazine from the side Up to 100 cleat nails can be loaded into magazine Be noted that when holding the L cleat nails the side with the L head should be in the left of the magazine side shelter Press the lock button then the pusher set back to make the magazine side shelter down back 1 2 3 FIG 6 FIG 7 LOADING CLEAT NAILS LOADING STAP...

Page 8: ...ped or if the hammer cap is accidentally struck then the tool will fire a fastener potentially causing SERIOUS PERSONAL INJURY Keep your feet off the tool Before using the tool on a floor test the tool on a scrap piece of wood Adjust the driving depth by providing more or less air pressure contacting the work surface Then using the mallet packet with the tool strike the hammer cap firmly to drive ...

Page 9: ... Bolt Make sure there is no fastener in magazine before clearing a jam Disconnect the tool from the air source whenever clearing a jam After disconnecting the tool from the air compressor there should still be enough air pressure to fire the tool After the air hose is disconnected always fire the tool into scrap wood repeatedly to make sure all of the compressed air is expended HOOKUP INSTRUCTIONS...

Page 10: ...e the air compressor is set between 70psi and 115psi Clean exhaust channel Not shooting fasteners Damaged pusher spring Wrong size of fasteners Replace spring Use 1 2 crown staples Fix the drive channel Replace the piston Remove the bent fasteners replace with the 1 2 crown staples Clean magazine Tighten screws Verify that fasteners are the correct size Drive channel is worn Piston is broken or wo...

Page 11: ...om normal wear neglect abuse accident or repair attempted Driver blades bumpers O rings piston and piston rings are considered normally wearing parts To take advantage of this warranty the product or part must be returned to us If our inspection verifies the defect we will either repair or replace the product With continuing product development changes may have occurred that the product you receiv...