background image

17

Surface depth setting

When the main line is cut or broken off.....

Attention

1.

When new line is wound up, or when line has been pulled under heavy tension, line 

stretch may cause a gap in the depth reading at the surface.  Simply reset the surface 
setting with the 

RESET BUTTON

.

Before you begin fishing, make sure the counter is set to zero at the waterʼs surface. 

This is extremely important to ensure accurate fishing depth readings.

3.

  Lower  the  terminal  rig  to  the  waterʼs  surface  and  press  the 

RESET BUTTON

. (water surface zero setting) 

The display resets to 

0.0

.

2

1.

  Connect  the  reel  to  the  battery,  put  the  line  through  all  the 

guides, and prepare your terminal rig.

2.

 Place the rod into the rod holder in the position it will normally 

rest while fishing.

- Should your line break, revise data as follows.

- Wind the line to the rod tip, and press the 

RESET BUTTON

 for 2 

seconds.  (At  depths  greater  than  10  m,  2-second-pressing  is 

employed  accidental  pressing  of  the  button.)  If  the  display 

shows 

0.0

  then  your  re-adjustment  is  complete  and  data  has 

been revised.

- Unless you reset the data on the reel, it will not be able to count 

accurately. 

Functional setting operation 

(2. Before you begin fishing.)

3

Summary of Contents for Seaborg 500Fe

Page 1: ...or purchasing a SEABORG 500Fe To take full advantage of the reels many useful functions please read this manual carefully before using Retain this manual for future reference OPERATING MANUAL Referenc...

Page 2: ...ng Surface depth setting When the main line is cut or broken off 3 Auto stop function Auto stop setting Auto stop 4 Inverse counter Inverse counter 5 Live lining mode Live lining mode setting Live lin...

Page 3: ...ould cut your skin 5 Use this reel for fishing purposes only 6 Be careful not to get reel grease on your clothing 7 Do not use metal wire for the main line 8 Sharp impacts due to inadvertent drop or o...

Page 4: ...blink if voltage gets below DC 9 V If the display shows this when the motor is not running then battery voltage is likely to be low In this case replace the battery with a recharged one Attention 1 W...

Page 5: ...ossibly damaging it 4 Do not use metal wire as the reel s main line The following conditions may make the display difficult to read 1 Wearing polarized glasses 2 Excessively cold or hot weather mid wi...

Page 6: ...bmerse the reel when washing 2 Do not use organic solvents such as benzene and thinner 3 Do not use a steel brush or abrasive cleanser 4 Do not attempt to look inside the oil hole The oil may splash a...

Page 7: ...l is a precision instrument that employs electric circuity and motor Do not disassemble the reel by yourself Cover the power connector on the reel with its protection cap Old or worn cords can cause a...

Page 8: ...done while line is being fed RESET BUTTON This button resets the depth counter to zero Make sure to press this button before you start fishing The reset depth is used to make the auto stop function wo...

Page 9: ...the motor is running Display Function Chumming timer starts working Auto Line feeding is employed Default setting is off Pressing the RESET BUTTON makes this indicator appear telling you auto stop wil...

Page 10: ...functions of each part Free spool adjustment Waterproof tournament drag Power lever Clutch Level wind Enclosed items Manual CD R Power cord Storage bag Reel guard oil Levelwind threader weak strong lo...

Page 11: ...ull to avoid line breakage 1 Adjust the drag while reel is on the rod and the line is strung through all the line guides 2 Adjust drag with the clutch ON while pulling the line with your hands Normall...

Page 12: ...l read 0 0 Press and hold the MODE SETTING BUTTON for five seconds When the button is released the default setting will show 8 The power lever can be used to change from the default value to other lin...

Page 13: ...sion indicator Keep line tension between level 4 and 5 while winding on line 2 Move the power lever to the OFF position 6 When the button is released the display will then change to the figure on the...

Page 14: ...00 is the default setting 9 Pull the lever back to the OFF position after winding 11 Enter the line length with the power lever in the figure on the right line length is 280 m 12 Press RESET BUTTON fo...

Page 15: ...der makes this process easier Make sure to tie the line onto the pin found on the spool to avoid the line slipping 7 Press the MODE SETTING BUTTON for 5 seconds when the display will show 0 0 P1 will...

Page 16: ...Then hold down RESET BUTTON at least 2 seconds The figure at the bottom of the display will change from 50 to 100 11 Similarly wind the remaining 50 m of the main line and hold down RESET BUTTON at l...

Page 17: ...can be retained by pressing the RESET BUTTON Except turning ON and OFF of Live Lining mode Power lever MODE BUTTON MODE BUTTON MODE BUTTON MODE BUTTON MODE BUTTON MODE BUTTON MODE BUTTON jig pickup p...

Page 18: ...UTTON and MODE BUTTON simultaneously for 5 seconds Functionalsettingoperation 1 Mode setting display MODE BUTTON MODE BUTTON MODE BUTTON MODE BUTTON MODE BUTTON MODE BUTTON Jigging length Jig waiting...

Page 19: ...e RESET BUTTON water surface zero setting The display resets to 0 0 2 1 Connect the reel to the battery put the line through all the guides and prepare your terminal rig 2 Place the rod into the rod h...

Page 20: ...p function Auto stop Auto stop automatically brings your terminal rig to the surface stopping consistently at your pre set depth preference It eliminates the need to constantly monitor depth as it com...

Page 21: ...range is 94 m which is 6 m from the bottom 2 At the bottom move the clutch to ON by turning the reel handle or flipping the clutch lever 3 After winding up any slack line press the INVERSE COUNTER BU...

Page 22: ...e the power lever to activate the Live Line Function 4 Turn it ON using the power lever When the Live line alarm is OFF the alarm will not sound When the line spools out faster than the preset range t...

Page 23: ...as well as wave and swell size The available setting range is 1 to 10 When INVERSE COUNTER BUTTON is pressed the depth of stored strike zone will be calculated to one decimal place and then will be s...

Page 24: ...er or press RESET BUTTON to show the display shown on the right This display is the pickup setting display Use While the power lever is at MAX position pressing the BPICKUP BUTTON makes the motor run...

Page 25: ...ower lever Interval time Jigging distance 1 Press the MODE BUTTON to show Jig pickup display When jigging is chosen the pickup function cannot be used 2 Jigging pattern is selected with the power leve...

Page 26: ...you require Pressing the PICKUP JIGGING BUTTON starts jigging with the display showing the indicator Pressing the button once more cease jigging The power lever controls jigging speed Shifting of jig...

Page 27: ...etting Attention If jigging time is longer than the chumming timer setting then the chumming timer setting takes priority and will wind up the line Three step jigging Three step jigging Three step jig...

Page 28: ...DE BUTTON three times to show 0 0 depth counter to complete The will blinks While the reel is feeding line with this function its speed cannot be changed adjustment of line furnishing the figure corre...

Page 29: ...e INVERSE COUNTER BUTTON The chumming timer will not function if the indication of the depth counter goes out of range 20m and 20m It will not function any more if once the indication of the depth cou...

Page 30: ...lays the time passed after the presentation of your bait or lure It can be used for chumming jigging timing or reeling in your rig The chumming timer starts from 7 0 m on the counter unless a specific...

Page 31: ...splay real fishing time and total winding length OFF MAX 3 4 After 100 0 is reached then press the MODE BUTTON to return to depth display With this procedure the inverse counter is reset In the revise...

Page 32: ...h Switch alarm Each time a button is pressed a confirming beep is sounded Excessive voltage alarm Should you attach a power source with a voltage higher than the acceptable level a continuous alarm wi...

Page 33: ...winding Instant max winding power power voltage 12 V smallest radius of spool Specifications may be changed without prior notice for the purpose of improvement Upper counter 0 0 999 9 m Lower counter...

Page 34: ...LATE SCREW SET PLATE IDLE GEAR A COLLAR IDLE GEAR A IDLE GEAR A SCREW IDLE GEAR B IDLE GEAR C COLLAR IDLE GEAR C IDLE GEAR C RETAINER SET PLATE GEAR SET PLATE GEAR BALL BEARING SET PLATE GEAR RING SET...

Page 35: ...worn or corroded It is a normal function to avoid over winding Press RESET BUTTON to continue winding Pull the lever to OFF and then move forward again to start winding Use another power source such...

Page 36: ...TED WARRANTY TERMS 12851 MIDWAY PLACE CERRITOS CA 90703 U S A WARRANTY WILL EXPIRE WHEN ONE OF THE FOLLOWING HAS BEEN SURPASSED 562 802 9589 ONE YEAR FROM DATE OF ORIGINAL PURCHASE 200 TOTAL HOURS OF...

Reviews: