background image

Technical Information

Service Manual

Function and Control

Remote Controller Introduction

Icon Display on Remote Controller

Operation introduction of remote controller

Buttons on Remote Controller

Note:

1

2

5

4

6

7

8

11

12

9

On/Off button

▲/     button

3

Fan button

Swing button

X-Fan button

Turbo button

Light button

10

Temp button

I Feel button

Timer button

Sleep  button

Mode button

2

5

7

9

4

12

3

1

6

8

10

11

Send signal

Turbo mode

8

ć

 heating function

Set temperature

Set time

TIMER ON /TIMER OFF

Child lock

Up & down swing

Set fan speed

Light function

Temp. display type

:Set temp.

:Outdoor ambient temp.

:Indoor ambient temp.

Sleep mode

Heat mode

Fan mode

Dry mode

Cool mode

Auto mode

Operation mode

I feel function

X-fan mode

health function 
ventilation operation

 “      ” This is a general remote controller. Some models have this function while some  do not. Please refer to the 
actual models. 

● This is a general use remote controller, it could be used for the air conditioners with multifunction; For some function, which
the model doesn't have, if press the corresponding button on the remote controller that the unit will keep the original running status.
●After putting through the power, the air conditioner will give out a sound.Operation indictor "    " is ON (red indicator). After that, 
you can operate the air conditioner by using remote controller.
● Under on status, pressing the button on the remote controller, the signal icon "     "on the display of remote controller will

blink once and the air conditioner will give out a “de” sound, which means the signal has been sent to the air conditioner.

● Under off status, set temperature and clock icon will be displayed on the display of remote controller (If timer on, timer off and 
light functions are set, the corresponding icons will be displayed on the display of remote controller at the same time); Under on 
status, the display will show the corresponding set function icons.

Summary of Contents for ASD 12UI-DB

Page 1: ...Service Manual Models ASD 9UI DB ASD 12UI DB ASD 18UI DB ASD 21UI DB...

Page 2: ...Application Area m2 12 18 16 24 Indoor Unit Model of Indoor Unit 6 6 3URGXFW RGH RI QGRRU 8QLW DQ 7 SH URVV RZ URVV RZ LDPHWHU HQJWK mm DQ 0RWRU RROLQJ 6SHHG 6 0 6 r min 1300 1200 1100 850 1350 1200 1...

Page 3: ...EH Pipe Diameter mm 5RZV Q DS mm 1 1 4 1 1 4 RLO HQJWK mm DQ 0RWRU 6SHHG rpm 900 900 2XWSXW RI DQ 0RWRU W 30 30 DQ 0RWRU 5 A 0 36 0 36 DQ 0RWRU DSDFLWRU LU ORZ 9ROXPH RI 2XWGRRU 8QLW m3 K 1600 2200 DQ...

Page 4: ...Technical Information Service Manual Outline Dimension Diagram Indoor Unit Unit mm Models W H D W1 W2 W3 09 12K 773 250 185 131 462 180 D H W 75 35 55 W3 W2 W1 55 35 75...

Page 5: ...Technical Information Service Manual Outdoor Unit 257 780 596 842 286 540 320 Unit mm 09K 12K Unit mm 320 782 510 712 257 286 540...

Page 6: ...ease refer to the actual models This is a general use remote controller it could be used for the air conditioners with multifunction For some function which the model doesn t have if press the corresp...

Page 7: ...m AUTO COOL DRY FAN and HEAT as the following AUTO COOL DRY FAN HEAT Note Only for models with heating function This button is used for setting Fan Speed in the sequence that goes from AUTO to then ba...

Page 8: ...d buttons simultaneously 3s to lock or unlock the keypad If the remote pressing any button blinks three times controller is locked is displayed In this case Combination of and buttons About lock About...

Page 9: ...me models Replacement of batteries in remote controller Emergency operation If remote controller is lost or damaged please use auxiliary button to turn on or turn off the air conditioner When the air...

Page 10: ...DFK FRQGLWLRQ PELHQW WHPSHUDWXUH LV 7DPE 7FRPSHQVDWLRQ IRU KHDW SXPS XQLW DQG 7DPE IRU FRROLQJ RQO XQLW I WKHUHV IHHO IXQFWLRQ 7FRPSHQVDWLRQ LV 2WKHUV DUH VDPH DV DERYH 5 Fan mode 8QGHU WKLV PRGH LQGR...

Page 11: ...RUUHVSRQGLQJ UHPRWH FRQWURO FRGH FXUUHQW VHW WHPSHUDWXUH ZLOO EH displayed 2QO ZKHQ UHPRWH FRQWURO VLJQDO LV VZLWFKHG WR LQGRRU DPELHQW WHPSHUDWXUH GLVSOD VWDWXV FRUUHVSRQGLQJ UHPRWH FRQWURO FRGH IURP...

Page 12: ...HVHW 7LQGRRU DPELHQW WHPSHUDWXUH 7FRPSHQVDWLRQ 1 XQLW RSHUDWHV DFFRUGLQJ WR WKH SUHYLRXV VWDWXV KHQ 7SUHVHW 7LQGRRU DPELHQW WHPSHUDWXUH 7FRPSHQVDWLRQ FRPSUHVVRU VWRSV RSHUDWLRQ DQG RXWGRRU IDQ ZLOO VW...

Page 13: ...WLQJ XQGHU WKLV PRGH IDQ VSHHG ZLOO DGMXVW DFFRUGLQJ WR DXWR IDQ VSHHG LI FRPSUHVVRU VWRSV RSHUDWLRQ XQGHU WKLV PRGH LQGRRU IDQ ZLOO EH LQ UHVLGXDO KHDW EORZLQJ VWDWXV When power on communication ligh...

Page 14: ...it adequately grounded The grounding wire cant be used for other purposes 6 Must apply protective accessories such as protective boards cable cross loop and wire clip 7 The live wire neutral wire and...

Page 15: ...KDW OLTXLG YDOYH DQG JDV valve are fully closed and power is disconnected before detaching the connection pipe If compressor starts running when stop valve is open and connection pipe is not yet conne...

Page 16: ...OWLQJ LQ LQMXU 3URKLELW LQVWDOOLQJ WKH XQLW DW WKH SODFH ZKHUH WKHUH PD EH OHDNHG FRUURVLYH JDV RU DPPDEOH JDV I WKHUH OHDNHG JDV DURXQG WKH XQLW LW PD FDXVH H SORVLRQ DQG RWKHU DFFLGHQWV 7 Do not use...

Page 17: ...OO YHQWLODWHG The continuous ventilation status should be kept during the operation process KHFN ZKHWKHU WKHUH LV UH VRXUFH RU SRWHQWLDO UH VRXUFH LQ WKH PDLQWHQDQFH DUHD 7KH QDNHG DPH LV SURKLELWHG L...

Page 18: ...tape 4 Electroprobe 7 Electronic leakage detector 10 Pipe pliers pipe cutter 2 Screw driver 5 Universal meter 8 Vacuum pump 11 Pipe expander pipe bender 3 Impact drill drill head electric drill 6 Tor...

Page 19: ...ast 15cm At least 50cm At least 50cm At least 30cm At least 300cm Space to the obstruction Space to the obstruction Space to the obstruction Space to the ceiling Space to the obstruction Space to the...

Page 20: ...r unit Make the bound pipes pass through the wall hole and then connect outdoor unit Neaten the pipes Vacuum pumping and leakage detection Check after installation and test operation Finish installati...

Page 21: ...LW SOHDVH QRWH WKH IROORZLQJ WDEOH LU VZLWFK VKRXOG EH LQFOXGHG PDJQHW EXFNOH DQG KHDWLQJ EXFNOH IXQFWLRQ LW FDQ SURWHFW WKH FLUFXLW VKRUW DQG RYHUORDG DXWLRQ SOHDVH GR QRW XVH WKH IXVH RQO IRU SURWHF...

Page 22: ...H SRVLWLRQ RI SLSLQJ KROH VKRXOG EH D OLWWOH ORZHU WKDQ WKH ZDOO PRXQWHG IUDPH V VKRZ LQ LJ 5 Connect the Pipe of Indoor Unit LP WKH SLSH MRLQW DW WKH FRUUHVSRQGLQJ EHOOPRXWK V VKRZ LQ LJ 3UHWLJKWHQLQ...

Page 23: ...QJ FRYHU DQG WKHQ WDNH GRZQ WKH FRYHU V VKRZ LQ LJ 8 Bind up Pipe LQG XS WKH FRQQHFWLRQ SLSH SRZHU FRUG DQG GUDLQ KRVH ZLWK WKH EDQG V VKRZ LQ LJ 5HVHUYH D FHUWDLQ OHQJWK RI GUDLQ KRVH DQG SRZHU FRUG...

Page 24: ...ROLQJ DQG KHDWLQJ XQLW WR WKH ZLULQJ WHUPLQDO DFFRUGLQJ WR WKH FRORU WKHP ZLWK VFUHZV V VKRZ LQ LJ 6 Neaten the Pipes 7KH SLSHV VKRXOG EH SODFHG DORQJ WKH ZDOO EHQW UHDVRQDEO DQG KLGGHQ SRVVLEO 0LQ VH...

Page 25: ...U ZDVWHU eletricity The water outlet can t be placed in water 1 Use Vacuum Pump 5HPRYH WKH YDOYH FDSV RQ WKH OLTXLG YDOYH DQG JDV YDOYH DQG WKH QXW RI UHIULJHUDQW FKDUJLQJ YHQW RQQHFW WKH FKDUJLQJ KRV...

Page 26: ......

Reviews: