GB
105
Appendix
(1) Command of electric lock or strike. 12 V/1.5 A max.
No external power needed.
(2) Command of a motorized gate, output relay: dry contact 48 Vcc/1 A
If a push button for manual control of the automatic device is already installed, connect terminals 17
and 18 in parallel to this input of the gate controller.
The gate control equipment requires external power.
(3) Connection is not obligatory; link out the 2 terminals if not used.
Allows for the state of the door to be displayed on the handsets LCD screen:
-
door closed (contact closed)
-
door open (contact open)
(4) Connection not obligatory
Push button placed inside the door allowing manual egress control.
Place this control out of reach and view from the street if fitted to pedestrian gate.
(5) Connection not obligatory; link out the two terminals if not used
Allows for the state of the gate to be displayed on the handsets LCD screen:
-
gate closed (contact closed)
-
gate open (contact open)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
door
caller unit
gate
not
used
look (1)
position
contact (3)
manual lock
command
button (4)
yellow
br
own
gr
ey
gr
een
pink
white
automatic gate
controller PCB
manual
motorised
gate command
button
position
contact (5)
NC
NC
manual
override
input
(2)