[24]
Rev 4/15/14
Dairy Tech, Inc.
Service Manual:
DT10G, DT30G &DT60G
Set-Up Menu for ProVu control
These are the parameters to be set for the Dairy Tech controls.
SETUP WIZARD -
Don’t reset to factory defaults!
Enter the menu by first powering the unit and wait for the self check to be completed.
While holding the RETURN button, press the UP arrow to enter the main menu.
Scroll to select the SETUP WIZARD using the UP and DOWN buttons.
Enter the security password which is 10.
Thermocouple:
Type E
Engineering Units:
F or C depending on country ***hint*** if you select C,
the profiles must individually be changed to Celsius as
well. This is not automatic for the profiles***
Decimal Point Position:
123.4
Scale Input Range Lo Limit:
0
(make sure it is 0 when in Celsius)
Scale Input Range Upper Limit:
300
(make sure it is set to 100 in Celsius)
Control Type:
Single
Primary Control Action:
Reverse
Select Automatic or Manual Control:
Automatic
Output 1:
Primary Power
Output 2A:
Event & Alarm
OP2A Usage:
Event 1, Direct Acting
Output 2B:
Event & Alarm
OP2B Usage:
Event 2, Direct Acting
Output 3:
Event & Alarm
OP3 Usage:
Event 3, Direct Acting
Setpoint Selection:
Local Setpoint 1 Only
Local Setpoint 1 Value:
7.0 F
Alarm 1: Unused
Alarm 2: Unused
Alarm 3: Unused
Alarm 4: Unused
Alarm 5: Unused
Date Type:
mm/dd/yyyy
Date enter
Day enter
Time enter
Run Pre-Tune: NO
Summary of Contents for Platinum Series
Page 2: ...2 Rev 4 15 14 Dairy Tech Inc Service Manual DT10G DT30G DT60G...
Page 31: ...31 Rev 4 15 14 Schematic for Model DT10 30 60G 200 to 240VAC 1P 50 60Hz USA Domestic...
Page 32: ...32 Rev 4 15 14 Schematic for Model DT10 30 60G 200 to 240VAC 1P 50 60Hz England Japan...
Page 33: ...33 Rev 4 15 14 Schematic for Model DT10 30 60G 400VAC 3P Europe...
Page 34: ...34 Rev 4 15 14 NOTES...
Page 38: ...38 Rev 4 15 14...