background image

Tetra

®

 MAX

Installation Guide

www.gecurrent.com

© 2021 Current Lighting Solutions, LLC. All rights reserved. GE and the GE monogram are trademarks of the 

General Electric Company and are used under license. Information provided is subject to change without 

notice. All values are design or typical values when measured under laboratory conditions. 
SIGN208 (Rev 06/29/21)  GE2032-1428

18 AWG/0.82 mm

Supply Wire

16 AWG/1.31 mm

Supply Wire

14 AWG/2.08 mm

Supply Wire

12 AWG/3.31 mm

Supply Wire

25W Power Supply

120 ft./36.6 m

-

-

-

80W Power Supply

20 ft./6.1 m

25 ft./7.6 m

35 ft./10.6 m

40 ft./12.1 m

100W Power Supply

20 ft./6.1 m

25 ft./7.6 m

35 ft./10.6 m

40 ft./12.1 m

180W Power Supply

20 ft./6.1 m

25 ft./7.6 m

35 ft./10.6 m

40 ft./12.1 m

200W Power Supply

20 ft./6.1 m

25 ft./7.6 m

35 ft./10.6 m

40 ft./12.1 m

300W Power Supply

20 ft./6.1 m

25 ft./7.6 m

35 ft./10.6 m

40 ft./12.1 m

Maximum Remote Mounting Distance from Driver Output

NOTE: The maximum loading claimed in the table is at ambient temperature 25°C (77°F).

For linear long runs, center connection to the LED strip is recommended to minimize voltage drop.

Maximum Loading per 24V DC Power Supply

Power Supply

GEMX24RD-W1

GEMXH24RD-W1

GEMX24GL-W1

GEMX24BL-W1

GEMX24YG-W1

Rating per module

24VDC


19mA/module


0.456W/module

24VDC


31mA/module


0.744W/module

24VDC


32mA/module


0.768W/module

24VDC


29mA/module


0.696W/module

24VDC


16mA/module


0.384W/module

GEPS24-25U-NA 

Load shall not exceed 1.04A

47 modules/


31.3 ft. (9.55 m)

29 modules/


19.3 ft. (5.89 m)

28 modules/


18.7 ft. (5.69 m)

31 modules/


20.7 ft. (6.3 m)

56 modules/


37.3 ft. (11.38 m)

GEPS24D-80U 

GEPS24W-80  

Load shall not exceed 3.3A

150 modules/


100 ft. (30.48 m)

92 modules/


61.3 ft. (18.69 m)

89 modules/


59.3 ft. (18.08 m)

98 modules/


65.3 ft. (19.91 m)

180 modules/


120 ft. (36.58 m)

GEPS24-100U-GLX 

USVI-100024FBA 

USVI-100024FE 

Load shall not exceed 4.0A

180 modules/


120 ft. (36.58 m)

110 modules/


73.3 ft. (22.35 m)

107 modules/


71.3 ft. (21.74 m)

118 modules/


78.6 ft. (23.98 m)

210 modules/


140 ft. (42.67 m)

GEPS24-180U 

Load shall not exceed 3.8A per 

each (of 2) output channels

168 modules/

112 ft. (34.14 m)


per bank


336 modules/


224 ft. (68.27 m)


per PS

103 modules/


68.7 ft. (20.93 m)


per bank


206 modules/


137.3 ft. (41.86 m)


per PS

100 modules/


66.7 ft. (20.32 m)


per bank


200 modules/


133.3 ft. (40.64 m)


per PS

110 modules/


73.3 ft. (22.35 m)


per bank


220 modules/


146.7 ft. (44.7 m)


per PS

200 modules/


133.3 ft. (40.64 m)


per bank


400 modules/


266.7 ft. (81.28 m)


per PS

GEPS24-300U-GL 

Load shall not exceed 4.0A 

per 

each (of 3) output channels

180 modules/


120 ft. (36.58 m)


per bank


540 modules/


360 ft. (109.7 m)


per PS

110 modules/


73.3 ft. (22.35 m)


per bank


330 modules/


220 ft. (67 m)


per PS

107 modules/


71.3 ft. (21.74 m)


per bank


321 modules/


214 ft. (65.23 m)


per PS

118 modules/


78.6 ft. (23.98 m)


per bank


354 modules/


236 ft. (71.93 m)


per PS

210 modules/


140 ft. (42.67 m)


per bank


630 modules/


420 ft. (128 m)


per PS

GEPS24-100U-GLX2/TT  

Load shall not exceed 4.0A

190 modules/


126.6 ft. (38.58 m)

116 modules/


77.3 ft. (23.5 m)

113 modules/


75.3 ft. (22.9 m)

124 modules/


82.6 ft. (25.1 m)

226 modules/


150.6 ft. (45.9 m)

GEPS24-200U-GLX2 

Load shall not exceed 4.0A per 

each (of 2) output channels

190 modules/


126.6 ft. (38.5 m)

per bank


380 modules/


253.2 ft. (77.2 m)


per PS

116 modules/


77.3 ft. (23.5 m)

per bank


232 modules/


154.6 ft. (47.1 m)


per PS

113 modules/


75.3 ft. (22.9 m)

per bank


226 modules/


150.6 ft. (45.9 m)


per PS

124 modules/


82.6 ft. (25.1 m)

per bank


248 modules/


165.2 ft. (50.3 m)


per PS

226 modules/


150.6 ft. (45.9 m)

per bank


452 modules/


301.2 ft. (91.8 m)


per PS

GEPS24-300U-GLX2 

Load shall not exceed 4.0A per 

each (of 3) output channels

190 modules/


126.6 ft. (38.5 m)

per bank


570 modules/


379.8 ft. (155.8 m)


per PS

116 modules/


77.3 ft. (23.5 m)

per bank


348 modules/


231.9 ft. (70.7 m)


per PS

113 modules/


75.3 ft. (22.9 m)

per bank


339 modules/


225.9 ft. (68.8 m)


per PS

124 modules/


82.6 ft. (25.1 m)

per bank


372 modules/


247.8 ft. (75.5 m)


per PS

226 modules/


150.6 ft. (45.9 m)

per bank


678 modules/


451.8 ft. (137.7 m)


per PS

This product is intended solely for the use of non-residential signage lighting and is not intended for use in any other applications.

Conforms to the following standards: IP66 rated

III

Summary of Contents for GE Tetra MAX

Page 1: ...rmacija nalazi se na sljedečoj lokaciji https products gecurrent com eu HU A telepítési útmutató és a biztnosági információk magyar nyelvű változata az alábbi címen található https products gecurrent com eu IT La versione italiana del manuale di installazione e sicurezza può essere reperita nella seguente sezione https products gecurrent com eu LT Lietuvišką diegimo instrukcijos ir saugos informac...

Page 2: ...ité d entrée de l enseigne L installation de cet équipement de remplacement DEL peut impliquer le perçage ou le poinçonnage de trous dans la structure du panneau Vérifiez le câblage et les composants inclus pour éviter d endommager le câblage et les composants électriques Ne pas faire ou modifier les trous ouverts dans une enceinte de câblage ou de composants électriques pendant l installation de ...

Page 3: ...s LED modules should be mounted on UL recognized clear acrylic or polycarbonate The light output from the LED system should be directed back into the sign enclosure This will allow for uniform backlighting of the sign and will provide simple mounting Before you begin clean surfaces and remove all debris from the inside of the channel letter Clean the surfaces with a 50 50 mixture of isopropyl alco...

Page 4: ...E Refer to Maximum Loading Remote Mounting Specifications on page 5 Connect the red stripe wire of the LED strip to the red wire of the power supply Connect the white wire of the LED strip to the black or blue wire of the LED power supply NOTE All electrical connections should be suitably protected from mechanical damage and the environment Seal all connections in wet locations with electrical gra...

Page 5: ...h circuit supplying the existing transformer or ballast will be within the voltage ratings of the new LED power supply and have a current rating not exceeding 20A or that permitted by applicable local state or country electrical codes whichever is less 2 Existing Signs Only Remove the existing lighting equipment to be replaced such as neon tubing or fluorescent tubes and associated transformers an...

Page 6: ... m 210 modules 140 ft 42 67 m GEPS24 180U Load shall not exceed 3 8A per each of 2 output channels 168 modules 112 ft 34 14 m per bank 336 modules 224 ft 68 27 m per PS 103 modules 68 7 ft 20 93 m per bank 206 modules 137 3 ft 41 86 m per PS 100 modules 66 7 ft 20 32 m per bank 200 modules 133 3 ft 40 64 m per PS 110 modules 73 3 ft 22 35 m per bank 220 modules 146 7 ft 44 7 m per PS 200 modules 1...