Tetra

®

 MAX

Installation Guide

2

   

T

C

 Measure Point

 

WARNING / AVERTISSEMENT

RISK OF ELECTRIC SHOCK

 ∙

Turn power off before inspection, installation or removal.

 ∙

Properly ground power supply enclosure.

RISK OF FIRE

 ∙

Use only suitably approved wire for input/output 

connections. Minimum size 18 AWG (0.82mm

2

)

 ∙

Follow all local codes.

 ∙

Not to be submerged or used in a marine environment.

RISQUES DE DÉCHARGES ÉLECTRIQUES

 ∙

Coupez l’alimentation avant l’inspection, l’installation ou le déplacement.

 ∙

Assurez-vous de correctement mettre à terre l’alimentation électrique.

RISQUES D’INCENDIE

 ∙

N’utilisez que des fils approuvés par UL pour les entrées/sorties de connexion. Taille 

minimum 18 AWG (0.82mm

2

)

 ∙

Respectez tous les codes locaux.

 ∙

Ne pas submerger ou installer dans un environnement marin.

 

UL WARNING / AVERTISSEMENT UL

RISK OF FIRE OR ELECTRIC SHOCK

 ∙

LED Retrofit Kit installation requires knowledge of 

sign electrical systems. If not qualified, do not attempt 

installation. Contact a qualified electrician. 

 ∙

Install this kit only in host signs that have been identified in 

the installation instructions and where the input rating of the 

retrofit kit does not exceed the input rating of the sign.

 ∙

Installation of this LED retrofit kit may involve drilling or 

punching of holes into the structure of the sign. Check for 

enclosed wiring and components to avoid damage to wiring 

and electrical parts.

 ∙

Do not make or alter any open holes in an enclosure of 

wiring or electrical components during kit installation.

RISQUE D’INCENDIE OU DE CHOC ÉLECTRIQUE 

 ∙

L’installation de l’équipement de remplacement DEL exige Ia connaissance des 

systèmes électriques pour enseignes. Si non qualifié, ne tentez pas d’installation. 

Veuillez contacter un électricien qualifié. 

 ∙

Risque d’incendie ou de choc électrique. Installez cet ensemble seulement dans des 

enseignes hôtes qui ont été identifiés dans les instructions d’installation et dont la 

capacité d’entrée de l’ensemble ne dépasse pas la capacité d’entrée de l’enseigne.

 ∙

L’installation de cet équipement de remplacement DEL peut impliquer le perçage 

ou le poinçonnage de trous dans la structure du panneau Vérifiez le câblage et 

les composants inclus pour éviter d’endommager le câblage et les composants 

électriques.

 ∙

Ne pas faire ou modifier les trous ouverts dans une enceinte de câblage 

ou de composants électriques pendant l’installation de cet équipement de 

remplacement DEL.

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful 

interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits 

are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment 

generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful 

interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be 

required to correct the interference at his own expense.
This Class [A] RFLD complies with the Canadian standard ICES-005. Ce DEFR de la classe [A] est conforme à la NMB-005  du Canada.

1

1

2

2

3

3

4

4

5

5

6

6

7

7

Components

UL approved 18 AWG (0.82 mm

2

) supply wire

UL approved 22-14 AWG (0.33-2.08 mm

2

) wire connectors or 

22-18 AWG (0.33-0.82 mm

2

) in-line/IDC connectors

#6 (M3) screws, 1/8 inch (3.2 mm) rivets, or electrical grade RTV 

silicone or equivalent
Weather box GEXNWB2 (optional)
24 Volt Power Supply
Tetra® MAX LED modules
Electrical grade RTV silicone:
•  Momentive RTV 6700 Series Silicone Rubber Adhesive Sealant

•  Momentive White Blanc RTV 162 Silicone Rubber Adhesive 

Sealant-Electrical Grade

•  Dow Corning 3140 - Non-Corrosive Flowable (clear)

•  Dow Corning 3145 - Non-Corrosive Nonflowable (clear or gray)

•  Dow Corning RTV 748 Non-Corrosive Sealant-White

Summary of Contents for GE Tetra MAX

Page 1: ...rmacija nalazi se na sljedečoj lokaciji https products gecurrent com eu HU A telepítési útmutató és a biztnosági információk magyar nyelvű változata az alábbi címen található https products gecurrent com eu IT La versione italiana del manuale di installazione e sicurezza può essere reperita nella seguente sezione https products gecurrent com eu LT Lietuvišką diegimo instrukcijos ir saugos informac...

Page 2: ...ité d entrée de l enseigne L installation de cet équipement de remplacement DEL peut impliquer le perçage ou le poinçonnage de trous dans la structure du panneau Vérifiez le câblage et les composants inclus pour éviter d endommager le câblage et les composants électriques Ne pas faire ou modifier les trous ouverts dans une enceinte de câblage ou de composants électriques pendant l installation de ...

Page 3: ...s LED modules should be mounted on UL recognized clear acrylic or polycarbonate The light output from the LED system should be directed back into the sign enclosure This will allow for uniform backlighting of the sign and will provide simple mounting Before you begin clean surfaces and remove all debris from the inside of the channel letter Clean the surfaces with a 50 50 mixture of isopropyl alco...

Page 4: ...E Refer to Maximum Loading Remote Mounting Specifications on page 5 Connect the red stripe wire of the LED strip to the red wire of the power supply Connect the white wire of the LED strip to the black or blue wire of the LED power supply NOTE All electrical connections should be suitably protected from mechanical damage and the environment Seal all connections in wet locations with electrical gra...

Page 5: ...h circuit supplying the existing transformer or ballast will be within the voltage ratings of the new LED power supply and have a current rating not exceeding 20A or that permitted by applicable local state or country electrical codes whichever is less 2 Existing Signs Only Remove the existing lighting equipment to be replaced such as neon tubing or fluorescent tubes and associated transformers an...

Page 6: ... m 210 modules 140 ft 42 67 m GEPS24 180U Load shall not exceed 3 8A per each of 2 output channels 168 modules 112 ft 34 14 m per bank 336 modules 224 ft 68 27 m per PS 103 modules 68 7 ft 20 93 m per bank 206 modules 137 3 ft 41 86 m per PS 100 modules 66 7 ft 20 32 m per bank 200 modules 133 3 ft 40 64 m per PS 110 modules 73 3 ft 22 35 m per bank 220 modules 146 7 ft 44 7 m per PS 200 modules 1...

Reviews: