background image

Tetra

®

 MAX

LED Lighting System

Installation Guide

SIGN208 | GE2032-1428

GEMX24RD-W1, GEMXH24RD-W1, GEMX24GL-W1, 

GEMX24BL-W1, GEMX24YG-W1

RETROFIT SIGN CONVERSION LED KIT FOR USE ONLY IN 

ACCORDANCE WITH KIT INSTRUCTIONS.

KIT IS COMPLETE ONLY WHEN ALL PARTS REQUIRED BY 

THE INSTRUCTIONS ARE PRESENT.

TROUSSE DE CONVERSION À DEL POUR LA 

MODERNISATION DES ENSEIGNES

À UTILISER CONFORMÉMENT AU GUIDE D’INSTALLATION.

Save These Instructions

Use only in the manner intended by the manufacturer. If 

you have any questions, contact the manufacturer.

For the latest North American install guides for your product go to: https://products.gecurrent.com/led-signage-lighting 

For the latest European install guides for your product go to: https://products.gecurrent.com/eu

FOR UL ONLY

BG

  Българската версия на инструкциите за инсталаця и 

информация за безопасност могат да бъдат намерени 

на следния адрес: https://products.gecurrent.com/eu

CS

  Návod k montáží a bezpečnostní informace v češtině 

najdete zde: https://products.gecurrent.com/eu

DA

  Den danske version af installationsvejledningen og 

sikkerhedsoplysninger kan findes på følgende placering: 

https://products.gecurrent.com/eu

DE

  Die deutsche Version der Installationsanleitung und 

Sicherheitsinformationen finden Sie in folgendem Verzeic: 

https://products.gecurrent.com/eu

EL

  Μπορείτε να βρείτε την ελληνική εκδχή των  οδηγιών   

νγκατάστασης και των πληροφοριών ασφάλειας στην 

εξής τοποθεσία: https://products.gecurrent.com/eu

ES

  La versión española de las instrucciones de instalación y 

la información sobre seguridad puede encontrarse en la 

siguiente ubicación: https://products.gecurrent.com/eu

ET

  Eestikeelse paigaldusjuhendi ja ohutusnñuded leiate 

aadressilt: https://products.gecurrent.com/eu

FI

  Asennusohjeiden ja turvallisuustietojen suomenkielinen 

versio löytyy seuraavasta paikasta: https://products.

gecurrent.com/eu

FR

  La version française des instructions d’installations 

et information de sécurité est disponible à l’adresse 

suivante: https://products.gecurrent.com/eu

HR

  Hrvatska verzija priručnika za ugradnju i sigurnosnih 

informacija nalazi se na sljedečoj lokaciji: https://products.

gecurrent.com/eu

HU

  A telepítési útmutató és a biztnosági információk magyar 

nyelvű változata az alábbi címen található: https://

products.gecurrent.com/eu

IT

  La versione italiana del manuale di installazione e 

sicurezza può essere reperita nella seguente sezione: 

https://products.gecurrent.com/eu

LT

  Lietuvišką diegimo instrukcijos ir saugos informacijos 

versiją galima rasti šioje vietoje: https://products.

gecurrent.com/eu

LV

  Uzstādīšanas instrukciju un drošības informāciju latviešu 

valodā var atrast šeit: https://products.gecurrent.com/eu

NL

  De Nederlandse versie van de installatie-instructies en 

veiligheidsinformatie kan op de volgende locatie worden 

gevonden: https://products.gecurrent.com/eu

PL

  Polską wersję instrukcji instalacji oraz informacje 

dotyczące bezpieczeństwa można znaleźć w następującej 

lokalizacji: https://products.gecurrent.com/eu

PT

  A versão em Português das instruções de instalação e 

das informações de segurança pode ser encontrada na 

seguinte localização: https://products.gecurrent.com/eu

RO

  Versiunea în limba română a instrucţiunilor de instalare 

şi a informaţiilor de siguranţă pot fi găsite la: https://

products.gecurrent.com/eu

SV

  Ni hittar den svenska versionen av 

installationsanvisningarna och säkerhetsinformationen på 

följande plats: https://products.gecurrent.com/eu

SL

  Previdnostna opozorila in varnostne informacije so na 

zadnji strani vodnika za namestitev. Pred začetkom 

namestitve izdelka jih skrbno preberite: https://products.

gecurrent.com/eu

SK

  Slovenskú verziu montažnej príručky a bezpečnostn

ŷ

ch 

instrukcií nájdete na nasledujúcej lokalite: https://

products.gecurrent.com/eu

BEFORE YOU BEGIN

Read these instructions completely and carefully.

24

24

Volt

Prepare Electrical Wiring 

Electrical Requirements

•  Acceptable for use in dry, damp and wet locations.

•  The grounding and bonding of the LED Driver shall be 

done in accordance with National Electric Code (NEC) 

Article 600.

•  Follow all National Electric Codes (NEC) and local codes.

•  These products are only suitable for connection to a 

circuit from a Class 2 power source.

•  These products have not been evaluated for use when 

connected to a power source that does not comply with 

Class 2 voltage and energy limited supplies.

EN

Summary of Contents for GE Tetra MAX

Page 1: ...rmacija nalazi se na sljedečoj lokaciji https products gecurrent com eu HU A telepítési útmutató és a biztnosági információk magyar nyelvű változata az alábbi címen található https products gecurrent com eu IT La versione italiana del manuale di installazione e sicurezza può essere reperita nella seguente sezione https products gecurrent com eu LT Lietuvišką diegimo instrukcijos ir saugos informac...

Page 2: ...ité d entrée de l enseigne L installation de cet équipement de remplacement DEL peut impliquer le perçage ou le poinçonnage de trous dans la structure du panneau Vérifiez le câblage et les composants inclus pour éviter d endommager le câblage et les composants électriques Ne pas faire ou modifier les trous ouverts dans une enceinte de câblage ou de composants électriques pendant l installation de ...

Page 3: ...s LED modules should be mounted on UL recognized clear acrylic or polycarbonate The light output from the LED system should be directed back into the sign enclosure This will allow for uniform backlighting of the sign and will provide simple mounting Before you begin clean surfaces and remove all debris from the inside of the channel letter Clean the surfaces with a 50 50 mixture of isopropyl alco...

Page 4: ...E Refer to Maximum Loading Remote Mounting Specifications on page 5 Connect the red stripe wire of the LED strip to the red wire of the power supply Connect the white wire of the LED strip to the black or blue wire of the LED power supply NOTE All electrical connections should be suitably protected from mechanical damage and the environment Seal all connections in wet locations with electrical gra...

Page 5: ...h circuit supplying the existing transformer or ballast will be within the voltage ratings of the new LED power supply and have a current rating not exceeding 20A or that permitted by applicable local state or country electrical codes whichever is less 2 Existing Signs Only Remove the existing lighting equipment to be replaced such as neon tubing or fluorescent tubes and associated transformers an...

Page 6: ... m 210 modules 140 ft 42 67 m GEPS24 180U Load shall not exceed 3 8A per each of 2 output channels 168 modules 112 ft 34 14 m per bank 336 modules 224 ft 68 27 m per PS 103 modules 68 7 ft 20 93 m per bank 206 modules 137 3 ft 41 86 m per PS 100 modules 66 7 ft 20 32 m per bank 200 modules 133 3 ft 40 64 m per PS 110 modules 73 3 ft 22 35 m per bank 220 modules 146 7 ft 44 7 m per PS 200 modules 1...