background image

Installation Guide

IND259 | A-1028951

Lumination

®

 LED Luminaire

RC/LRC/RX/LRX Series - New Construction Installation

BEFORE YOU BEGIN 

Read these instructions completely and carefully.

  

WARNING / AVERTISSEMENT

RISK OF ELECTRIC SHOCK

• Turn power off before inspection, installation or removal.

• Properly ground electrical enclosure.

RISK OF FIRE

• Follow all NEC and local codes.

• Use only UL approved wire for input/output connections. 

   Minimum size 18 AWG (0.75mm2).

• Do not install insulation within 3 inches (76 mm) of luminaire top.

Prepare Electrical Wiring

Electrical Requirements

• The LED luminaire must be connected to the mains

   supply according to its ratings on the product label. 

• Class 1 wiring should be in accordance with NEC.

Grounding Instructions

• The grounding and bonding of the overall system 

   shall be done in accordance to local electric code of 

   the country where the luminire is installed.

RISQUES DE DÉCHARGES ÉLECTRIQUES

• Coupez l’alimentation avant d’inspecter, installer ou déplacer le luminaire.

• Assurez-vous de correctement mettre à la terre le boîtier d’alimentation électrique.

RISQUES D’INCENDIE

• Respectez tous les codes NEC et codes locaux.

• N’utilisez que des fils approuvés par UL pour les entrées/sorties de connexion. 

   Taille minimum 18 AWG (0.75mm2).

• Maintenir une distance de 76 mm (3 pouces) entre le luminaire et l’isolant.

Save These Instructions

Use only in the manner intended by the manufacturer.

If you have any questions, contact the manufacturer.

This device complies with Part 15 of the FCC Rules. Operation is

subject to the following two conditions: (1) This device may not cause

harmful interference, and (2) this device must accept any interference

received, including interference that may cause undesired operation.

CAN ICES-005(A)/NMB-005(A)

Note: This equipment has been tested and found to comply with the

limits for a Class A digital device, pursuant to part 15 of the FCC Rules.

These limits are designed to provide reasonable protection against

harmful interference when the equipment is operated in a commercial

environment. This equipment generates, uses, and can radiate radio

frequency energy and, if not installed and used in accordance with

the instruction manual, may cause harmful interference to radio

communications. Operation of this equipment in a residential area

is likely to cause harmful interference in which case the user will be

required to correct the interference at his own expense.

Summary of Contents for GE current Lumination RC Series

Page 1: ...tous les codes NEC et codes locaux N utilisez que des fils approuv s par UL pour les entr es sorties de connexion Taille minimum 18 AWG 0 75mm2 Maintenir une distance de 76 mm 3 pouces entre le lumin...

Page 2: ...e hole diameter matches fixture diameter Option A Mount fixture by attaching hanger bars to T Grid ceiling BH3 SKU 94890 Option B Mount fixture with 1 2 EMT conduit not supplied Adjust fixture height...

Page 3: ...ert AC line wires into the PSU box through the knockout hole and connect wires see wiring diagrams to the right 6 7 RC LRC Series Mounting RX Series skip to step 15 LRXR and LRXG Series skip to step 1...

Page 4: ...de of the L bracket This is necessary in order to make sure that when the springs release the L bracket does not interfere and prevent the springs from making contact with the top of the ceiling for p...

Page 5: ...Connect the black white and green yellow wires of the input leads to the black white and green AC line wires using UL Listed twist on wire connectors and close the junction box see wiring diagram Con...

Page 6: ...connections Connect the black white and green yellow wire of the input leads to the black white and green wires using twist on wire connectors and close junction box Optional dimmer When connecting a...

Page 7: ...select 3500K and DOWN to select 5000K Note For 10inch and 12inch adjustable lumen fixtures the default lumen output is set to 6000lm Push switch left to activate 5000lm and 4000lm respectively Adjusti...

Page 8: ...nd tilted up to 35 vertically Note it is recommended to use gloves while handling and adjusting the Gimbal light engine to prevent dirt and oils from contaminating the surface of the luminaire Load sp...

Reviews: