8

For BRC1C62

4

Press the fan speed control button and select 
the fan speed of your preference.

5

Press air flow direction adjust button. 

 

Refer to the chapter “

6.3 Adjusting the air 

flow direction

” for details.

For BRC1E62

4,5

Press air flow setting button

•  To select air volume or direction setting,

 

press “ 

 ” buttons. 

•  With air volume selected, 

 

using the “ 

 ” buttons.

•  With direction selected,

 

using the “ 

 ” buttons.

Stopping the system

6

Press the ON/OFF button once again. 

 

The operation lamp goes off and the system 
stops operation.

NOTICE

•  Do not turn off the power immediately 

after the unit stops, but wait for at least 

 

5 minutes.

•  The system need at least 5 minutes for 

residual operation of drain pump device. 
Turning off the power immediately will 
cause water leak or trouble.

Explanation of heating operation

It may take longer to reach the set temperature for 
general heating operation than for cooling operation.
The following operation is performed in order to 
prevent the heating capacity from dropping or cold 
air from blowing.

Defrost operation

•  In heating operation, freezing of the outdoor 

unit’s air cooled coil increases over time, 
restricting the energy transfer to the outdoor 
unit’s coil. Heating capability decreases and the 
system needs to go into defrost operation to be 
able to deliver enough heat to the indoor units:

•  When an outdoor unit is operating defrost, 

 

the indoor unit will stop fan operation, the 
refrigerant cycle will reverse and energy from 
inside the building will be used to defrost the 
outdoor unit coil.

•  The indoor unit will indicate defrost operation on 

the displays “ 

 ”.

Hot start

In order to prevent cold air from blowing out of an 
indoor unit at the start of heating operation, the 
indoor fan is automatically stopped. The display of 
the user interface shows “ 

 ”.  

It may take some time before the fan starts. This is 
not a malfunction.

INFORMATION

•  The heating capacity drops when the 

outside temperature falls. If this happens, 
use another heating device together with 
the unit. (When using together with 
appliances that produce open fire, 
ventilate the room constantly). 

 

Do not place appliances that produce 
open fire in places exposed to the air flow 
from the unit or under the unit.

•  It takes some time to heat up the room 

from the time the unit is started since the 
unit uses a hot-air circulating system to 
heat the entire room.

•  If the hot air rises to the ceiling, leaving 

the area above the floor cold, we 
recommend that you use the circulator 
(the indoor fan for circulating air). Contact 
your dealer for details.

6.2 

Program dry operation

•  The function of this program is to decrease the 

humidity in your room with minimal temperature 
decrease (minimal room cooling).

•  The microcomputer automatically determines 

temperature and fan speed 

 

(cannot be set by the user interface).

•  The system does not go into operation if the 

room temperature is low (<20°C).

Starting the system

2,4

3

1

2,4

BRC1C62

BRC1E62

01_EN_3P344160-11V.indd   8

08-Oct-20   9:22:56 AM

Summary of Contents for VRV Series

Page 1: ...System Air Conditioner OPERATION MANUAL RSUYQ4AVM RSUYQ5AVM RSUYQ6AVM RSUYQ4AVMA RSUYQ5AVMA RSUYQ6AVMA RSUYQ7AYM RSUYQ8AYM 00_CV_3P344160 11V indd 1 08 Oct 20 9 22 43 AM...

Page 2: ...ccurs After reading the manual keep it in your custody for future reference See also the operation manual included with the indoor unit for details on the indoor unit Store the operation manual includ...

Page 3: ...t heating operation 13 9 13 The inside of an outdoor unit is warm even when the unit has stopped 13 9 14 Does not cool very well 13 9 15 Hot air can be felt when the indoor unit is stopped 14 10 Troub...

Page 4: ...tions without fail There are two kinds of safety precaution and tips listed in the following WARNING Failure to follow these instructions properly may result in personal injury or loss of life This un...

Page 5: ...s this may result in electric shocks or fire Be sure to install an earth leakage breaker Failure to install an earth leakage breaker may result in electric shocks or fire In order to avoid electric sh...

Page 6: ...he unit as this may impair combustion of the burner Do not place burners or heaters in places exposed to the air flow from the unit as this may impair combustion of the burner or heater Do not place h...

Page 7: ...on instruments food plants animals or works of art as this may adversely affect the performance quality and or longevity of the object concerned After prolonged use check the unit stand and its mounts...

Page 8: ...del and indoor unit model combinations VRV direct expansion indoor units air to air applications RA direct expansion indoor units air to air applications Combination of VRV direct expansion indoor uni...

Page 9: ...e power turns back on again 6 1 Cooling heating fan only automatic operation and dry operation The operation mode cannot be changed with the remote controller whose display shows changeover under cent...

Page 10: ...it will stop fan operation the refrigerant cycle will reverse and energy from inside the building will be used to defrost the outdoor unit coil The indoor unit will indicate defrost operation on the d...

Page 11: ...and the air flow direction is fixed Fixed air flow direction setting For BRC1E62 1 Press air flow setting button To select air volume or direction setting press buttons With direction selected using...

Page 12: ...How to designate the master user interface 1 2 BRC1C62 BRC1E62 1 2 In case only VRV indoor units are connected to the VRV system 1 Press the operation mode selector button of the current master user i...

Page 13: ...sing a decrease in the cooling or heating effect Be careful not to cool or heat too much To save energy keep the temperature setting at a moderate level Never place objects near the air inlet or the a...

Page 14: ...oner troubles 9 1 The system does not operate The air conditioner does not start immediately after the ON OFF button on the user interface is pressed If the operation lamp lights the system is in norm...

Page 15: ...the system a small amount of refrigerant is kept flowing A pishi pishi squeaking sound is heard when the system stops after heating operation Expansion and contraction of plastic parts caused by tempe...

Page 16: ...during operation the system automatically restarts immediately after the power supply is recovered Check if no fuse has blown or breaker has worked Change the fuse or reset the breaker if necessary T...

Page 17: ...lf as incorrect dismantling or installation may cause an electric shock or fire Contact your dealer In case of accidental refrigerant leaks make sure there are no naked flames The refrigerant itself i...

Page 18: ...tioning Recommended replacement cycle of wear parts Table 2 Replacement Cycle list Component Inspection cycle Maintenance cycle replacements and or repairs Air filter 1 year 5 years High efficiency fi...

Page 19: ...f4 Abnormal suction temperature outdoor f6 Refrigerant overcharge detection H3 High pressure switch was activated H5 Overload protector malfunction H7 Fan motor trouble outdoor H9 Ambient temperature...

Page 20: ...The two dimensional bar code is a manufacturing code 3P344160 11V M19N113A 2010 HT 00_CV_3P344160 11V indd 3 08 Oct 20 9 22 43 AM...

Reviews: