background image

•  Outdoor Units • VRV HEAT RECOVERY • REYHQ16-24P  

1

9

•  VRV Systems • Outdoor Units  

35

9

Installation

9 - 3

Refrigerant pipe selection

REYQ18-48P819
REYHQ-P

4PW48463-1

Exa

mple of

 connec

tio

n

(C

o

nne

cti

on

 of

 8 i

n

do

or

 un

it

s)

Branch 

with refne

t j

oint

Br

anch w

ith

 ref

net

 jo

in

t and

re

fne

t heade

r

Bra

nch wi

th r

ef

net

 hea

der

Out

do

or un

it

in

s

ta

lle

d in

 a 

m

u

ltip

le

 

out

do

or

 u

n

it

 

system

(REYQ18~

48 +

R

REYHQ20~

24)

Use

 t

h

e o

u

td

o

o

r un

it 

m

u

lti co

nn

ectio

n

 p

ip

ing

 kit t

h

at is so

ld 

se

p

a

ra

te

ly 

a

s

 an

 op

ti

on

 (B

HFQ

2

3

P

90

7+

13

57

) f

o

th

e mu

lt

in

st

a

lla

ti

on

 of o

u

td

o

o

r un

it

s.

 S

e

lectio

n

 me

th

od

 is a

s

 sh

own

 in

 

th

e r

igh

t t

a

b

le

.

Inst

all th

e jo

in

t p

a

rt 

(

 p

a

rt in

 the

 fig

ure) o

f th

e o

u

td

o

o

r un

it multi 

co

n

n

e

c

ti

on

 pip

in

g kit

 ho

rizo

ntal

ly wit

h a

tt

e

nt

io

n t

o

 t

h

e in

st

a

lla

ti

on

 

re

str

ic

ti

ons des

cri

be

d in

 "

c

onn

ect

in

g

 t

he re

fr

iger

a

n

p

ipi

ng

".

(*

) I

n

 case

 of mu

lti comb

in

atio

n, in

te

rp

re

te the word

 "out

door

" as 

"first 

out

do

or

 b

ra

n

ch

".

M

ax

imu

allow

able

 length

B

e

tw

ee

out

do

or

 a

n

d

 i

ndo

or

 u

n

it

s

Actu

al pip

e

 

le

ng

th

Pi

p

e

 l

e

n

g

th

 b

e

tw

ee

out

do

or

(*

) an

d i

n

doo

r un

it

 16

5

m

[E

xam

pl

e]

 un

it

 8:

 a+

b+

c+

d+

e+

 16

5

m

[Exa

mp

le] u

n

it 

6: a

+

b

+

 1

6

5

m

uni

t 8: a+

m+

n+

 165

m

[E

xample

] un

it 8

: a+

 16

5

m

Equ

ivalen

le

ng

th

E

qui

vale

nt pi

pe le

ngth b

e

tw

een o

u

tdoor(*) and 

indo

or unit

s

 

 19

0

m

 (A

ss

ume e

quiv

alen

t pip

e len

gth of

 the ref

net jo

int to

 be 0

.5

m

, o

f the 

re

fnet h

eade

to be 1

.0

m

, of the

 B

S

V

Q

100 

and

 B

S

V

Q

160 

to be 

4

m

 an

d of t

he B

S

V

Q

25

0 to b

e

 6

m

 (

for cal

cula

tion 

purpos

es)) (S

ee n

ote 1)

T

o

ta

l ext

e

nsi

o

n

 

le

ng

th

T

o

ta

l p

iping

 len

gth

 from o

u

td

o

o

r(

*)

 to a

ll 

in

do

or u

n

it

 100

0

m

B

e

tw

ee

the

 fi

rs

t ou

td

oo

un

it

 m

u

lt

i con

ne

cti

o

n

 

p

ip

ing

 ki

t an

out

do

or

 u

n

it

 (

in c

a

se 

of a

 m

u

lt

ip

le

 

o

u

td

o

o

r un

it syste

m

)

Actu

al

 an

equ

iv

al

en

t pi

pe

 

le

ng

th

The

 act

ual

 pi

pe

 l

eng

th

 fr

om

 th

e f

ir

s

out

do

or

 u

n

it

 m

u

lt

conn

ect

io

n p

ipi

ng

 ki

t to

 th

e o

u

td

o

o

r u

n

it

 1

0

m

. (

x

10

m

, y

10

m

, z

10

m

)

The

 eq

ui

va

le

nt 

pi

pe

 l

e

n

g

th

 fr

om

 th

e f

ir

s

ou

td

oor

 u

n

it

 m

u

lt

con

nect

io

pi

pi

ng

 ki

t t

o

 th

e o

u

td

o

o

r u

n

it

 1

3

m

(x

13

m

, y

13

m

, z

13

m

)

A

llowabl

e he

ight

 

di

ff

er

ence

B

e

tw

ee

out

do

or

 a

n

d

 i

ndo

or

 u

n

it

s

D

if

fer

en

ce 

in

 he

ig

ht

 be

tw

ee

n o

u

td

o

o

r an

in

do

or

 un

it

s (

H

1)

50

m

 (

40

m if 

o

u

td

o

o

r un

it is 

lo

ca

ted

 in a

 l

o

we

r p

o

sitio

n)

.

B

e

tw

ee

in

do

or

 an

d i

n

do

or

 un

it

s

D

if

fer

en

ce 

in

 he

ig

ht

 be

tw

ee

n a

d

ja

ce

nt

 i

n

do

or

 u

n

it

(H

2

)

15

m

B

e

tw

ee

out

do

or

 a

n

d

 ou

td

oor

 u

n

it

s

D

if

fer

en

ce 

in

 he

ig

ht

 be

tw

ee

n a

d

ja

ce

nt

 ou

td

oor

 u

n

it

s (

H

3

)

5m

A

llowabl

e le

ngt

af

te

r the bra

nch

Actu

al pip

e

 

le

ng

th

Pi

p

e

 l

e

n

g

th

 fr

om

 f

ir

s

re

fr

iger

a

n

t b

ranch

 ki

t (

e

it

h

e

r r

e

fnet

 j

o

in

t or

 r

e

fnet

 he

ad

er

to i

n

do

or

 un

it

 

40

m

 (

S

ee

 no

te 

2)

[E

xam

pl

e]

 un

it

 8:

 b+

c+d

+

e

+

s

 

 4

0

m

[E

x

am

ple

] un

it

 6

: b+

l

4

0

m,

 un

it

 8:

 m+n

+p

40

m

[E

x

am

pl

e

] un

it

 8

: o 

 40

m

Out

door unit m

ul

ti connec

tion piping k

it and re

frigera

nt 

br

anch kit 

se

le

ction 

H

ow to

 s

el

ect

 th

e r

efn

et

 jo

in

t

Wh

en

 using

 r

e

fn

et 

joint

s

 at

 th

e fir

s

t b

ranch

 cou

nt

ed 

fr

om

 th

e o

u

td

o

o

r un

it side

, ch

oose

fr

om

 

the

 fo

llo

w

in

g t

a

b

le in 

acco

rd

an

ce with

 the

 cap

a

city of

 th

e o

u

tdoo

r un

it (

e

xa

mp

le:

re

fne

t join

A)

.

H

ow to

 s

el

ect

 th

e r

efne

t hea

der

C

h

oose fr

om 

the 

fo

llowi

ng t

able

 i

n

 ac

cor

dance wit

the tot

al

 cap

ac

it

y of all

 the i

ndoor

 uni

ts

 

connect

ed 

bel

ow t

he r

e

fnet 

header

.

No

te

250

 t

y

pe indo

or uni

t can not be connect

ed lo

w

e

r than th

re

fne

t header

header

 br

anch pi

pe.

O

ut

door unit

 ca

paci

ty 

type (Hp)

R

efri

ger

ant branch ki

t nam

e

Indoor  cap

aci

ty typ

e

Ref

ri

gerant

 b

ranch 

kit

 n

am

e

3 pip

es

2 pi

pes

8+

10

K

HRQ23M29T

 

200

KHRQ23M29H KHR

Q22M29H

12~

22

K

HRQ23M64T

200

 x 

 

290

KHRQ23M29H

KHR

Q22M29H

 

24

K

HRQ23M75T

290

 x 

 64

0

KHRQ23M64H

KHR

Q22M64H

For refn

et 

jo

int

s oth

er th

an

 th

e first b

ranch

, se

lect 

the

 prop

er b

ra

n

ch

 kit mod

e

l b

a

sed

 o

n

 th

tot

al ca

p

a

city in

dex 

of a

ll indo

or

 u

n

it

s

 con

nect

ed

 af

ter

 t

he 

re

fr

iger

a

n

t b

ranch

.

640

KHRQ23M75H

KHR

Q22M75H

H

ow

 to

 choose

 an 

ou

tdoor multi c

onnec

tion 

pi

ping ki

t (

this

 is 

require

d whe

th

sys

tem i

s a

 multiple

 out

door unit s

ys

te

m

)

In

door 

cap

acit

y type

Ref

rig

erant

 br

anch 

kit

 name

3 pi

pes

2 p

ipes

C

h

oose 

fr

om t

he f

o

llowi

ng 

table

 i

n

 ac

cor

dance 

wit

h t

he 

number 

of

 out

door

 u

n

it

s

 200

K

HRQ23M20T

KHRQ

22M20T

Number of out

door 

uni

ts

Bra

nch ki

t name

200

 x 

 

290

K

HRQ23M29T9

KHRQ

22M29T

290

 x 

 640

K

HRQ23M64T

KHRQ

22M64T

2

B

HFQ23P907

 640

K

HRQ23M75T

KHRQ

22M75T

3

B

HFQ23P1357

E

x

am

pl

of d

o

w

n

str

eam

 i

n

doo

r un

it

s

[Exa

mp

le

]

in

 case

 o

f r

e

fn

et 

jo

in

C:

 i

ndo

or

 u

n

it

s 5+

6+

7+

8

[E

x

a

mp

le

]

in

 case of re

fnet

 j

o

in

t B:

 i

ndoor

 uni

ts

 7+8,

in

 case of re

fnet

 he

ader:

 i

ndoo

r unit

s 1+

2+3+

4+

5+6

[E

xample]

in

 ca

se 

of r

e

fne

t he

ad

er

: i

n

doo

r un

it

1

+

2

+

3+

4+

5+

6+

7+

8

AB

C

D

E

ab

c

d

e

8

H2

H1

f

ln

p

B1

B2

B3

B4

F

h

1

g

G

j

2

k

mo

q

r

s

3

i

4

5

6

7

A

B

am

H2

H1

b

B1

B2

B3

B4

n

p

d

1

fh

g

j

i

kl

o

2

3

4

5

6

7

8

ce

B5

a

H2

H1

B1

B2

B3

B4

c

1

eg

f

i

hj

l

no

2

3

4

5

6

7

8

k

bd

B2

B3

m

Ou

tdoor

 un

it s

ide

 (

3

 pi

pes

)

Indo

or

 uni

t s

ide 

(2

 pip

es)

Su

ction

 ga

s pip

e

Gas 

pipe

HP

/LP

 ga

s pi

p

e

BS u

n

it

L

iqu

id

 pi

p

e

Li

qu

id

 p

ip

e

ind

oor

 u

n

it

re

fne

t h

e

ad

er

Out

d

oor

 u

n

it sid

e

 (

3

 pipe

s)

re

fn

et 

jo

in

t

o

ut

do

or

 m

u

lt

i co

nn

ecti

o

n

 p

ip

ing

 ki

t

Ind

oo

un

it

 si

de 

(2

 pi

p

e

s)

R

e

fr

ig

e

ra

n

br

an

ch ki

ts

 can

 o

n

ly

 be

 u

s

ed 

wi

th

 

R4

10

A

.

Summary of Contents for VRV Series

Page 1: ...ables 6 Combination table 6 Cooling capacity tables 7 Heating capacity tables 15 Capacity correction factor 23 5 Dimensional drawing centre of gravity 27 Dimensional drawing 27 Centre of gravity 28 6...

Page 2: ...2 088 Nr of Rows 54 54 54 54 Fin Pitch mm 2 2 2 2 Nr of Passes 18 18 18 21 18 21 21 21 Face Area m 2 112 2 112 2 112 2 481 2 112 2 481 2 481 2 481 Nr of Stages 2 2 2 2 Tube type Hi XSS 8 Fin Fin type...

Page 3: ...erature Capacity Control Method Inverter controlled Capacity Control 100 Safety devices HPS Fan motor driver overload protector Over current relay Inverter overload protector PC board fuse Standard Ac...

Page 4: ...rcuit breaker and the ground fault circuit interrupter earth leakage circuit breaker MSC means the maximum current during start up of the compressor Maximum allowable voltage range variation between p...

Page 5: ...al technical standard setting the limits for voltage changes voltage fluctuations and flicker in public low voltage supply systems for equipment with rated 75A 2 European International technical stand...

Page 6: ...RQ23M64T o o o o o KHRQ23M75T o o Ountdoor unit multipiping connection kit for H R BHFQ23P907 o BHFQ23P1357 o Central drain pan kit KWC26C280 o o o See note 4 See note 4 KWC26C450 o o See note 4 See n...

Page 7: ...V Systems Outdoor Units 6 Outdoor Units VRV HEAT RECOVERY REYHQ16 24P 4 Capacity tables 4 1 Combination table REYHQ P 4TW31481 1 UNIT REMQ8P9 REMQ10P8 REMHQ12P8 REYHQ16P 2 REYHQ20P 1 1 REYHQ22P 1 1 RE...

Page 8: ...7 50 4 8 4 51 1 8 4 51 7 8 5 53 0 8 5 54 4 8 6 25 36 4 5 59 43 5 7 2 49 7 8 7 50 3 8 8 51 0 8 8 52 3 8 9 53 6 9 0 27 36 4 5 97 43 5 7 7 49 0 9 1 49 6 9 2 50 3 9 2 51 6 9 3 52 9 9 4 29 36 4 6 37 43 5 8...

Page 9: ...2 69 25 4 3 21 29 5 3 76 31 5 4 04 33 5 4 34 37 6 4 94 41 7 5 56 20 21 3 2 74 25 4 3 27 29 5 3 83 31 5 4 12 33 5 4 42 37 6 5 04 41 7 5 71 21 21 3 2 76 25 4 3 30 29 5 3 87 31 5 4 16 33 5 4 46 37 6 5 1...

Page 10: ...1 64 4 11 2 66 0 11 3 67 7 11 4 25 45 4 7 40 54 1 9 5 61 8 11 6 62 7 11 6 63 5 11 7 65 1 11 8 66 7 11 9 27 45 4 7 90 54 1 10 2 60 9 12 1 61 7 12 1 62 6 12 2 64 2 12 3 65 8 12 4 29 45 4 8 43 54 1 10 9...

Page 11: ...51 9 7 22 18 26 5 3 56 31 6 4 25 36 7 4 98 39 2 5 35 41 7 5 74 46 8 6 54 51 9 7 36 20 26 5 3 62 31 6 4 32 36 7 5 07 39 2 5 46 41 7 5 85 46 8 6 67 51 9 7 56 21 26 5 3 65 31 6 4 36 36 7 5 12 39 2 5 51 4...

Page 12: ...8 12 8 70 7 12 9 72 5 13 0 74 3 13 1 25 49 8 8 52 59 4 11 0 67 9 13 3 68 8 13 4 69 7 13 4 71 5 13 6 73 3 13 7 27 49 8 9 10 59 4 11 7 66 9 13 9 67 8 13 9 68 7 14 0 70 5 14 1 72 3 14 3 29 49 8 9 7 59 4...

Page 13: ...38 57 0 8 31 18 29 1 4 10 34 7 4 89 40 3 5 73 43 1 6 16 45 9 6 61 51 4 7 52 57 0 8 47 20 29 1 4 17 34 7 4 98 40 3 5 84 43 1 6 28 45 9 6 74 51 4 7 67 57 0 8 71 21 29 1 4 21 34 7 5 02 40 3 5 89 43 1 6 3...

Page 14: ...8 76 4 13 9 77 4 14 0 79 3 14 1 81 3 14 2 25 54 3 9 2 64 7 11 8 74 3 14 4 75 3 14 5 76 3 14 6 78 3 14 7 80 2 14 9 27 54 3 9 8 64 7 12 6 73 2 15 0 74 2 15 1 75 2 15 2 77 2 15 3 79 1 15 5 29 54 3 10 4...

Page 15: ...3 62 1 8 9 18 31 7 4 41 37 8 5 26 43 9 6 16 46 9 6 63 50 0 7 10 56 0 8 1 62 1 9 1 20 31 7 4 48 37 8 5 35 43 9 6 27 46 9 6 75 50 0 7 24 56 0 8 2 62 1 9 4 21 31 7 4 52 37 8 5 40 43 9 6 33 46 9 6 82 50 0...

Page 16: ...6 3 10 8 36 3 11 0 36 2 11 2 36 1 11 6 9 5 10 0 37 4 10 21 37 3 10 6 37 2 11 0 37 1 11 2 37 1 11 4 37 0 11 8 8 5 9 1 38 2 10 4 38 1 10 7 38 0 11 1 37 9 11 3 37 9 11 5 37 8 11 9 7 0 7 6 39 6 10 6 39 5...

Page 17: ...8 11 0 35 9 12 6 35 9 12 9 35 0 12 7 33 9 12 2 32 8 11 7 30 5 10 7 9 5 10 0 36 8 12 7 36 7 13 0 35 0 12 3 33 9 11 8 32 8 11 4 30 5 10 4 8 5 9 1 37 6 12 8 37 3 12 9 35 0 12 0 33 9 11 5 32 8 11 1 30 5...

Page 18: ...12 9 44 4 13 4 9 5 10 0 45 9 11 7 45 8 12 2 45 7 12 6 45 6 12 9 45 6 13 1 45 4 13 6 8 5 9 1 46 9 11 9 46 8 12 4 46 7 12 8 46 6 13 0 46 5 13 3 46 4 13 7 7 0 7 6 48 6 12 2 48 4 12 6 48 3 13 1 48 3 13 3...

Page 19: ...11 0 44 1 14 6 44 0 14 9 43 8 15 1 42 3 14 5 40 9 13 9 38 1 12 8 9 5 10 0 45 2 14 7 45 1 15 0 43 8 14 7 42 3 14 1 40 9 13 5 38 1 12 5 8 5 9 1 46 1 14 8 46 0 15 1 43 8 14 3 42 3 13 7 40 9 13 2 38 1 12...

Page 20: ...4 9 48 4 15 2 48 3 15 7 9 5 10 0 49 9 13 7 49 8 14 2 49 7 14 8 49 6 15 1 49 5 15 4 49 4 15 9 8 5 9 1 51 0 13 9 50 9 14 4 50 8 15 0 50 7 15 3 50 6 15 5 50 5 16 1 7 0 7 6 52 9 14 3 52 8 14 8 52 6 15 3 5...

Page 21: ...8 11 0 48 0 17 1 47 9 17 5 47 8 17 8 46 7 17 4 45 2 16 7 42 1 15 4 9 5 10 0 49 1 17 3 49 0 17 6 48 3 17 6 46 7 16 9 45 2 16 3 42 1 14 9 8 5 9 1 50 2 17 4 50 1 17 7 48 3 17 1 46 7 16 5 45 2 15 8 42 1 1...

Page 22: ...17 1 56 5 17 3 56 3 17 9 9 5 10 0 58 2 15 8 58 1 16 4 58 0 17 0 57 9 17 3 57 8 17 6 57 7 18 1 8 5 9 1 59 5 16 1 59 3 16 6 59 2 17 2 59 1 17 5 59 0 17 7 58 9 18 3 7 0 7 6 61 6 16 4 61 4 17 0 61 3 17 5...

Page 23: ...17 8 45 8 16 4 9 8 11 0 56 0 19 3 55 9 19 7 52 5 18 2 50 8 17 5 49 1 16 8 45 8 15 5 9 5 10 0 57 3 19 5 55 9 19 1 52 5 17 7 50 8 17 0 49 1 16 4 45 8 15 1 8 5 9 1 58 5 19 6 55 9 18 6 52 5 17 3 50 8 16 6...

Page 24: ...is 90m or more the diameter of the main liquid pipes outdoor unit branch sections must be increased When level difference is 50m or more the diameter of the main gas and liquid pipes outdoor unit bra...

Page 25: ...3 1 4 VRV Systems Outdoor Units 24 Outdoor Units VRV HEAT RECOVERY REYHQ16 24P 4 Capacity tables 4 4 Capacity correction factor J J...

Page 26: ...uid pipes outdoor unit branch sections must be increased When level difference is 50m or more the diameter of the main gas and liquid pipes outdoor unit brach sections must be increased Diameter of ab...

Page 27: ...3 1 4 VRV Systems Outdoor Units 26 Outdoor Units VRV HEAT RECOVERY REYHQ16 24P 4 Capacity tables 4 4 Capacity correction factor H H B J H B J...

Page 28: ...22 5 mm Oblong holes foundation bolt hole No Parts name Remarks 4 Pressure equalizer pipe connection port 19 1 Brazing connection See note 2 5 Grounding terminal inside of switch box M8 6 Power cord r...

Page 29: ...ERY REYHQ16 24P 5 Dimensional drawing centre of gravity 5 2 Centre of gravity REMHQ12P8 3D057578B Center of foundation bolt hole Center of foundation bolt hole Center of foundation bolt hole Center of...

Page 30: ...Outdoor Units VRV HEAT RECOVERY REYHQ16 24P 1 6 VRV Systems Outdoor Units 29 6 Piping diagram H 2P8 J...

Page 31: ...valve pipe F5U Field fusef R90 Resistor current sensor Y3S 4 way valve H E Gas F400U Fuse T 63A 250V A2P R95 Resistor current limiting Y4S RMTL Y5S Hots gas H1P H8P Pilotlamp service monitor orange H...

Page 32: ...erates 2 Sound pressure level is a relative value depending on the distance and acoustic environment For more details please refer to sound level drawings 3 Mentioned values are theoretical values bas...

Page 33: ...3 1 8 VRV Systems Outdoor Units 32 Outdoor Units VRV HEAT RECOVERY REYHQ16 24P 8 Sound data 8 2 Sound power spectrum H 2P8...

Page 34: ...than are catered for in the above patterns your layout should take account of the possibility of short circuits 4 The units should be installed to leave insufficient space at the front for the on sit...

Page 35: ...is built shall have rough finish 4 A drain ditch shall be made around the foundation to thoroughly drain water from the equipment installation area 5 When installing the equipment on a roof the floor...

Page 36: ...pipe length Pipe length from first refrigerant branch kit either refnet joint or refnet header to indoor unit 40 m See note 2 Example unit 8 b c d e s 40 m Example unit 6 b l 40 m unit 8 m n p 40 m Ex...

Page 37: ...1 0 kg X 1 x 22 2 x0 37 X 2 x 19 1 x0 26 X 3 x 15 9 x0 18 X 4 x 12 7 x0 12 X 5 x 9 5 x0 059 X 6 x 6 4 x0 022 A B x 1 02 REY H Q A 1 0 kg 1 5 kg 2 0 kg 2 5 kg 3 0 kg 3 5 kg 4 0 kg 4 5 kg REYHQ 16 Hp 2...

Page 38: ...on Operation range NOTES 1 These figures assume the following operation conditions Indoor and outdoor units Equivalent pipe length 7 5m Level difference 0m 2 Depending on operation and installation co...

Reviews: