Easy and flexible design

5-1

Total room layout flexibility - VRVII & VRV-WII

VRVII systems are easily adaptable to changes in room layout : extra indoor units can be added to a VRV outdoor unit up to a capacity level of 130%. 

Also, since VRVII heat recovery systems offer simultaneous cooling and heating, existing indoor and outdoor units can continue to provide year round 
air conditioning from their existing locations, even if office layouts are altered or extended.

5-2

Complete flexibility - VRVII & VRV-WII

The VRVII/VRV-WII system enables different floors or even rooms to be rented to different customers, because each room has independent control of its air 
conditioning. 

Thanks to inverter technology, as many as 40 indoor units (32 indoor units for VRV-WII) with different types and capacities can be installed in one 
system. This system automatically and effectively controls each unit to provide individual rooms of different sizes with a comfortable working or 
living environment.

5-3

Year round cooling and/or heating

VRVII & VRV-WII

Designed to provide simultaneous year round cooling and/or heating, VRVII heat reovery systems are modular in concept and are therefore, ideal 
for use in rooms or zones that generate varying thermal loads according to building orientation or local cold or hot spots.

VRVII & VRV-WII

It is possible for the same meeting room to give rise to differing thermal loads depending on the time of day, number of occupants present, location 
and usage pattern of lighting and electronic office equipment.

VRVII & VRV-WII

Until the advent of the VRV, a complex 4-pipe fan coil was needed to meet this requirement.  The VRV however, is easier to design and install an in 
its heat recovery format, can conserve energy in two or more rooms at the same time.

VRV-WII

The colder it is outside, the warmer it needs to be indoors, which means that the capacity of the air-cooled outdoor unit drops. Water-cooled air 
conditioners are not subject to this problem. The boiler ensures that sufficient enough additional heat is always available indoors.

Room layout change

Indoor unit

addition

Office

Reception room

Stock room

Office

Meeting room

Meeting room

Meeting room

Meeting room

Summary of Contents for VRV II Series

Page 1: ...technical data Systems VRVII VRV WII Features...

Page 2: ...ty VRVII VRV WII 6 Low operation sound level VRVII 7 Operation range of outdoor temperature VRVII 8 3 High reliability Nr 1 anti corrosion treatment VRVII 9 Double back up function VRVII 10 Duty cycli...

Page 3: ...sary VRVII 16 Unified REFNET piping VRVII 17 Increased installation flexibility VRVII 17 High external static pressure 6mm H2O VRVII 17 4 way piping connection VRVII VRV WII 17 Downsizing refrigerant...

Page 4: ...n comparison with outdoor units capacity 5 HP outdoor units use inverter control compressors only 5HP Outdoor Unit Large Load Small 100 24 Inverter Control 210Hz 52Hz 20 Steps Compressor Capacity Cont...

Page 5: ...multiple compressors clearly results in minimum switching losses and power surges because of the overlap in capacity and frequency Since Daikin utilises small 5HP inverter compressors the influence of...

Page 6: ...acity indoor unit the bypass valve is controlled ON OFF with capacity control being executed at a minimum of 14 for a 5HP outdoor unit when operating one 20 class indoor unit or a minimum of 8 for 8 a...

Page 7: ...tdoor air close to indoor air conditions recovers energy loss realises considerable reduction of air conditioning capacity The heat exchanger modulates the humidity and temperature of incoming fresh a...

Page 8: ...ime can be input VRV WII Water cooled air conditioning can be acceptable in certain critical areas in which the operating sound of air cooled air conditioning could be a little intrusive This results...

Page 9: ...cooling only heat pump series to operate at outdoor ambients down to 5 C in cooling mode and down to 20 C in heating mode VRV WII Wide operating range of the water cooled units between 10 C 45 C both...

Page 10: ...test SS DIN 50021 96 hours humidity cycle test KFW DIN 50017 48 hours room temperature room humidity testing period 5 cycles contents of 1 cycle 48 hours according to DIN50018 0 21 testing period 40 c...

Page 11: ...s equalises compressor duty and extends operating life 3 4 Special oil equalising technology The incorporation of this technology ensures that the optimum quantity of oil is contained in each outdoor...

Page 12: ...vative application of new technology and the latest HFC refrigerants to its VRV product programmes 4 4 Less waste and improved re cycling VRVII The lead free soldered PCB obviates environmental contam...

Page 13: ...r living environment 5 3 Year round cooling and or heating VRVII VRV WII Designed to provide simultaneous year round cooling and or heating VRVII heat reovery systems are modular in concept and are th...

Page 14: ...ight can exist between the VRV WII and indoor units Water piping does not intrude on the occupied spaces so there are no leakage problems 40m if the VRV WII is below the indoor units NOTES 1 In this c...

Page 15: ...ages are possible 1 Expert mode Once the cooling and heating loads in the different rooms have been calculated the software will select the most appropriate system plus an estimate of the power consum...

Page 16: ...n of the project 6 2 Dramatic reduction in installation space VRVII VRVII features a dramatic reduction in installation space for example the 16hp outdoor unit is housed in a single casing outdoor uni...

Page 17: ...of a building in a commercial elevator overcoming site transportation problem particularly when outdoor units need to be installed on each floor 6 4 No structural reinforcement necessary VRVII The gal...

Page 18: ...ere refrigerant distribution is far from optimal the Daikin REFNET joints have specifically been designed to optimise refrigerant flow 6 6 Increased installation flexibility VRVII Outdoor units can be...

Page 19: ...liquid and gas pipe diameters Reduced piping costs thanks to modular design Smaller diameter liquid and gas piping contributes to a reduction in installation space and installation costs based on a 24...

Page 20: ...ring and piping This function identifies and alerts system errors by means of on off LEDs on the outdoor unit s PC boards 6 13 Simplified wiring VRVII VRV WII A simple 2 wire non shielded multiplex tr...

Page 21: ...fed from the front panel both left and right side panels or bottom panel of the outdoor unit 6 16 Auto address setting function VRVII VRV WII Allows wiring between indoor and outdoor units as well as...

Page 22: ...pertains to quality assurance regarding design development manufacturing as well as to services related to the product Daikin units comply with the European regulations that guarantee the safety of th...

Reviews: