Daikin VRV HXY48TAVJU Installation And Operation Manual Download Page 29

Installation and operation manual

28

HXY48TAVJU

VRV System indoor unit

3P616151-1A – 2021.12

14 

DEFROST/START UP MODE ICON 

d

This icon indicates that the defrost/start up mode is active.

15 

COMPRESSOR ICON 

ç

This icon indicates that the compressor in the outdoor unit of the
system is active.

16 

PUMP ICON 

é

This icon indicates that the circulation pump is active.

17 

OUTDOOR TEMPERATURE DISPLAY 

u

When  this  icon is flashing,  the  outdoor ambient  temperature  is
displayed.  Refer  to  "10.3.7. Temperature  read-out  mode"  on
page 31 for more information.

18 

WEATHER DEPENDENT SET POINT ICON 

a

This icon indicates that the controller will adapt the leaving water
temperature  set  point  automatically,  based  on  the  outdoor
ambient temperature (during heating operation).

19 

TEMPERATURE ICON 

b

This  icon  is  displayed  when  the  actual  room  temperature  or
room temperature set point is shown.
The icon is also displayed when the temperature set point is set
in 

schedule 

timer 

programming 

mode. 

Refer 

to

"10.3.7. Temperature  read-out  mode"  on  page 31  for  more
information.

20 

TEST OPERATION ICON 

t

This icon indicates that the unit runs in test mode.

21 

FIELD SET CODE 

;

This code represents the code from the field set list. Refer to the
"8.3. Field settings" on page 18.

22 

MALFUNCTION CODE 

:

This  code  refers  to  the  malfunction  code  list  and  is  for  service
purposes  only.  Refer  to  the  malfunction  code  list
"8.6.2. Malfunction codes list" on page 25.

23 

BUTTON 

w

This button has no function.

24 

WEATHER DEPENDENT SET POINT BUTTON 

ba

This button enables or disables the weather dependent set point
function which is available in space heating operation.
If  the  controller  is  set  to  permission  level 3  (refer  to  "Field
settings" in the installation manual), the weather dependent set
point button will not be operable.

25 

INSPECTION/TEST OPERATION BUTTON 

z

This button is used for installation purposes and changing field
settings. Refer to "8.3. Field settings" on page 18.

26 

PROGRAMMING BUTTON 

<

This multi-purpose button is used to program the controller. The
function  of  the  button  depends  on  the  actual  status  of  the
controller or on previous actions carried out by the operator.

27 

SCHEDULE TIMER BUTTON 

r

/

p

The  main  function  of  this  multi-purpose  button  is  to
enable/disable the schedule timer.
The  button  is  also  used  to  set  the  clock  and  to  program  the
controller.  The  function  of  the  button  depends  on  the  actual
status of the controller or on previous actions carried out by the
operator.

28 

TIME ADJUST BUTTONS 

pi

 and 

pj

These  multi-purpose  buttons  are  used  to  adjust  the  clock,  to
toggle  between  temperatures  (water  inlet/outlet  temperature  of
the unit, outdoor ambient temperature, actual room temperature)
and in schedule timer programming mode.

29 

LEAVING  WATER  TEMPERATURE  ADJUST  BUTTONS

ébi

 and 

ébj

These buttons are used to adjust the leaving water temperature
set  point  in  normal  operation  mode  or  in  schedule  timer
programming mode.
If  the  controller  is  set  to  permission  level 3  (refer  to  "Field
settings"  in  the  installation  manual),  the  leaving  water
temperature adjust button will not be operable.
In case the weather dependent set point operation is selected,
the unit has a floating set point. In this case, the 

a

 icon as well

as the shift value (in case not zero) will display.

30 

ROOM TEMPERATURE ADJUST BUTTONS 

bi

 and 

bj

These multi-purpose buttons are used to adjust the current room
temperature set point in normal operation mode or in schedule
timer programming mode.
When  changing  the  room  temperature  set  point,  the  set  point
value on the display will be flashing. After 5 seconds the display
will show to the actual room temperature.

31 

BUTTON 

S

This button has no function.

32 

BUTTON 

h

/

c

This button has no function.

10.3.3. Setting up the controller

After  initial  installation,  the  user  can  set  the  clock  and  day  of  the
week.

The controller is equipped with a schedule timer that enables the user
to  schedule  operations.  Setting  the  clock  and  day  of  the  week  is
required to be able to use the schedule timer.

Setting the clock

1

Hold down the 

pr

 button for 5 seconds.

The clock read-out and the day of week indicator start flashing.

2

Use the 

pi

 and 

pj

 buttons to adjust the clock.

Each  time  the 

pi

  or 

pj

  button  is  pressed,  the  time  will

increase/decrease  by  1 minute.  Keeping  the 

pi

  or 

pj

button pressed will increase/decrease the time by 10 minutes.

3

Use the 

ébi

 or 

ébj

 button to adjust the day of the week.

Each time the 

ébi

 or 

ébj

 button is pressed the next or

previous day is displayed.

4

Press the 

<

 button to confirm the current set time and day of the

week.
To leave this procedure without saving, press the 

pr

 button.

If  no  button  is  pressed  for  5 minutes  the  clock  and  day  of  the
week will return to their previous setting.

Setting the schedule timer

To  set  the  schedule  timer,  refer  to  chapter  "10.3.10. Programming
and consulting the schedule timer" on page 33.

Main

Sub

Permission

level 2

level 3

Operation ON/OFF

Setting the leaving water temperature

Setting the room temperature

Weather dependent set point operation 

ON/OFF

Setting the clock

Programming the schedule timer

Schedule timer operation ON/OFF

Field settings

malfunction code display

Test operation

 = operable

INFORMATION

The clock needs to be set manually. Adjust the setting
when  switching  from  summertime  to  wintertime  and
vice versa.

If the controller is set to permission level 2 or 3 (refer
to  "Field  settings"  in  the  installation  manual),  setting
the clock will not be possible.

A power failure exceeding 2 hours will reset the clock
and  the  day  of  the  week.  The  schedule  timer  will
continue  operation,  but  with  a  disordered  clock.
Therefor it will be needed to correct the clock and the
day of the week.

01_EN_3P616151-1A.fm  28 ページ  2021年12月14日 火曜日 午後1時29分

Summary of Contents for VRV HXY48TAVJU

Page 1: ...English Fran ais Espa ol INSTALLATION AND OPERATION MANUAL HXY48TAVJU System indoor unit 00_CV_3P616151 1A fm 1...

Page 2: ...rk 14 7 3 2 System overview of field wiring 15 7 3 3 Requirements 15 7 3 4 To open the switch box cover 15 7 3 5 To connect the electrical wiring on the indoor unit 15 7 3 6 To connect the user interf...

Page 3: ...fied personnel must carry out the installation work Installation must be done in accordance with this installation manual Improper installation may result in water leakage electric shock or fire When...

Page 4: ...additional refrigerant must be charged in its liquid state If the refrigerant is charged in a state of gas its composition can change and the system will not work properly The indoor unit is for R410...

Page 5: ...mage must be reported immediately to the carrier s claims agent Bring the packed unit as close as possible to its final installation position to prevent damage during transport 3 1 Indoor unit 3 1 1 T...

Page 6: ...ntification 4 2 1 Identification label Indoor unit Location Model identification Modelname HXY48TAVJU 4 3 Possible combinations of unit and options 4 3 1 List of options for indoor unit User interface...

Page 7: ...eaving water temperature zone B One single room C One single room a Outdoor VRV b VRV Direct Expansion DX Indoor unit cassette c HXY48 d Optional EKRUAHTB user interface main e Refrigerant piping f Wa...

Page 8: ...kage When installing the unit in a small room take measures in order to keep the refrigerant concentration from exceeding allowable safety limits in the event of a refrigerant leak Do not climb sit or...

Page 9: ...e is 50 F 10 C cooling The maximum water pressure is 44 psi 3 bar Provide adequate safeguards in the water circuit to ensure that the maximum pressure is NOT exceeded All installed piping and piping a...

Page 10: ...r volume Check that the total water volume in the installation is minimum 5 3 gallon 20 liter the internal water volume of the indoor unit NOT included a Outdoor unit VRV b Indoor unit HXY48 c Heat ex...

Page 11: ...35 H 10 4 35 0 10 4 35 psi 0 3 bar The corresponding maximum water volume at 4 35 psi 0 3 bar is 108 3 gal 410 l See the graph in the chapter above Because 92 gal 350 l is lower than 108 3 gal 410 l...

Page 12: ...1 Indoor unit power supply 2 GND a a Refer to name plate on the indoor unit 2 Malfunction output 2 0 3 A b b Minimum cable section 0 75 mm AWG18 3 Operation ON OFF output 2 0 3 A b 4 Cooling heating...

Page 13: ...he water outlet Mind their position Orientation of the integrated drain valves is important for servicing 1 Install the shut off valves on the water pipes a Water inlet b Water outlet c Adaptors 2 Scr...

Page 14: ...w switch During filling it may not be possible to remove all the air from the circuit Remaining air will be removed through the automatic air purge valves during the initial operating hours of the sys...

Page 15: ...50 50 Total hardness mg CaCO3 l 200 70 70 Calcium hardness mg CaCO3 l 150 50 Ionic state silica mg SiO2 l 50 30 30 Reference items Iron mg Fe l 1 0 0 3 1 0 0 3 Copper mg Cu l 0 3 0 1 1 0 0 1 Sulfate i...

Page 16: ...nd sharp edges 7 3 6 To connect the user interface The unit is equipped with a user interface offering a user friendly way to set up use and maintain the unit Before operating the user interface follo...

Page 17: ...ape of the backside of the user interface by overtightening the mounting screws a b P1 P2 a Rear part of the user interface b Front part of the user interface 1 2 1 NOTE Be careful NOT to distort the...

Page 18: ...is properly installed to avoid abnormal noises and vibrations when starting up the unit 6 Damaged equipment Check the inside of the unit on damaged components or squeezed pipes 7 Refrigerant leak Chec...

Page 19: ...he select field setting 5 Save the new value by pressing the pr button 6 Repeat step 2 through 4 to change other field settings as required 7 When finished press the z button to exit FIELD SET MODE 8...

Page 20: ...room temperature During operation During schedule timer operation the operation LED is lit continuously When pushing the y button The schedule timer for space heating will stop and will not start agai...

Page 21: ...roller and the real set point E g a positive shift value means that the real temperature set point will be higher than the calculated set point It is advised to use the weather dependent set point bec...

Page 22: ...l be used for the logic Eg when the ambient temperature is high during cooling mode the logic will correct the measured value of the leaving water thermistor to a lower value to take into account infl...

Page 23: ...01 High ambient temperature Hi_A 59 15 50 68 10 20 1 8 1 F C 02 Set point at low ambient temperature Lo_Ti 104 40 77 176 25 80 1 8 1 F C 03 Set point at high ambient temperature Hi_Ti 77 25 77 176 25...

Page 24: ...03 Set point cooling leaving water minimum temperature 50 10 41 64 5 18 1 8 1 F C 04 Not applicable Do not change the default value 0 d Settings are not applicable E Service mode 00 Not applicable Do...

Page 25: ...ave this mode If no button is pressed the user interface leaves the display mode after 10 seconds Procedure for space heating cooling 1 Check the leaving water and entering water temperature through t...

Page 26: ...onent box are hot Make sure you do not touch a conductive section Do not rinse the unit This may cause electric shocks or fire Play it safe Touch a metal part by hand such as piping sheet metal in ord...

Page 27: ...ace cooling heating operation Tick when checked Q Explain to the user what sytem is installed on site Complete the fill in below for each unit The information may be useful for the user in future serv...

Page 28: ...PECTION REQUIRED k and l These icons indicate that inspection is required on the installation Consult your dealer 11 TEMPERATURE DISPLAY 9 The display shows the current temperature of the installation...

Page 29: ...ERATURE ADJUST BUTTONS bi and bj These buttons are used to adjust the leaving water temperature set point in normal operation mode or in schedule timer programming mode If the controller is set to per...

Page 30: ...int The operation LED 0 lights up 2 Use the bi and bj buttons to set the desired room temperature Temperature range for heating 61 90 F 16 32 C room temperature In order to avoid overheating space hea...

Page 31: ...is enabled 3 Press the ba button to deactivate weather dependent set point operation The bi and bj buttons are used to set the leaving water temperature Field settings define the parameters for the we...

Page 32: ...g schedule timer can be programmed in 2 different ways Based on the temperature set point leaving water temperature and room temperature Based on the ON OFF instruction The desired method is set throu...

Page 33: ...ation LED will stop working However the schedule timer icon will stay displayed When pushing the pr button The schedule timer for space heating will be stopped and will not start again The schedule ti...

Page 34: ...This form can help you define the required actions for each day Take your time to enter all data accurately Try to program the actions in a chronological way start with action 1 for the first action...

Page 35: ...g water temperature 9 Use the bi and bj buttons to set the room temperature 10 Use the ba button to select x to switch cooling and the user interface off 11 Repeat steps 6 to 10 to program the other a...

Page 36: ...out as follows 1 Press the button to enter the programming consulting mode 2 Select the operation mode you would like to consult by means of the pi and pj buttons The actual mode is blinking 3 Press t...

Page 37: ...e unit There are 2 inputs that allow Remote thermo on off Remote unit on off For more details about this option kit refer to the wiring diagram of the unit 10 3 12 Operating the optional user interfac...

Page 38: ...field settings as required 7 When finished press the z button to exit FIELD SET MODE NOTE Changes made to a specific field setting are only stored when the pr button is pressed Navigating to a new fi...

Page 39: ...e this procedure for resetting the safety is not successful contact your local dealer For other malfunction codes which may be displayed during the system test run or operation see the installation ma...

Page 40: ...0A 2 1 8 F1U SS1 4 2 X12A 1 4 1 1 F1U 6 1 2 NORM EMG R1T BRN 1 208 230V 60Hz 2 2 X1M 2 X27A 2 2 YLW 3 K6R WHT 2 X5A 2 1 C3 X15A K1R C2 S1L HAP 2 X1M X1A 5 X15A 1 1 X14A BLU BLU 2 2 X20A X18A MS A1P L2...

Page 41: ...refrigerant of oil and of other parts must be done in accordance with the applicable legislation Do not try to dismantle the system yourself the dismantling of the system treatment of the refrigerant...

Page 42: ...Daikin Texas Technology Park 19001 Kermier Road Waller TX 77484 U S A 3P616151 1A EM21A030 2021 12 00_CV_3P616151 1A fm 2...

Reviews: