background image

To avoid injury, do not touch the air inlet or aluminum 

fins of the air conditioner.
Do not place objects in direct proximity of the outdoor 

unit and do not let leaves and other debris accumulate 

around the unit.

Leaves are a hotbed for small animals which can enter the 
unit. Once in the unit, such animals can cause malfunctions, 
smoke or a fire when making contact with electrical parts.
Do not block air inlets nor outlets.

Impaired airflow may result in insufficient performance 
or trouble.
Do not let children play on or around the outdoor unit.

If they touch the unit carelessly, injury may be caused.
Turn off the main power switch when the air 

conditioners is not to be uesd for prolonged periods.

When the main power switch is left on, some electrical
power (watts) is still consumed even if the air conditioner
is not operating. Therefore, switch off the main power 
switch to save energy. When resuming operation, to 
ensure smooth running, turn on the main power switch 
6 hours before operating the air conditioner again.
Never touch the internal parts of the remote controller.

Do not remove the front panel. Touching certain internal 
parts will cause electric shocks and damage to the remote 
controller. Please consult your local dealer about checking 
and adjustment of internal parts.
Do not leave the remote controller wherever there is a 

risk of wetting.

If water gets into the remote controller there is a risk of 
electrical leakage and damage to electronic components.
Be careful of scaffold when high-place work is 

required.

If the scaffold is unstable, you may fall or topple down, thus 
causing injury.
Be sure to fix air filter certainly.

Be sure to fix suction grille at knobs.

It may cause air filter and suction grille drop.
Take care of scaffolding and exercise caution when

working high above ground level.

2. NAMES AND FUNCTIONS OF PARTS

a

Remote controller (optional accessory) 
The remote controller may not be needed depending 
on the system configuration.

b

Air outlet

c

d

e

f

g

h

i

j

k

l

m

Horizontal blade (at air outlet)
Refrigerant piping
Transmission wiring

Drain piping

Air outlet identification mark

 )

Use this mark as a reference for setting the airflow 
direction.

j

a

i

b

c

d

e

g

f

k
l
m

h

Suction grille 
(Refer to 

“4. MAINTENANCE” on page 4)

Air filter (inside suction grille)
(Refer to 

“4. MAINTENANCE” on page 4)

Infrared presence sensor 
It detects whether or not someone is there by means 
of f

loor

 sensors corresponding to each air outlet.

Infrared floor sensor 
It detects the average temperature of the floor surface.

Drain discharge device (built-in) 
Discharges indoor moisture removed during the 
cooling operation.

Earth wiring (Note) 
(Note) It is a wiring to let electricity flow from the 
indoor unit to the earth for prevention of electric 
shocks or a fire in case of emergency. 

3

Summary of Contents for VRV FXFSQ25ARV16

Page 1: ......

Page 2: ...1...

Page 3: ...2...

Page 4: ...3...

Page 5: ...4...

Page 6: ...5...

Page 7: ...6...

Page 8: ...7...

Page 9: ...8...

Page 10: ...9...

Page 11: ...10...

Page 12: ...11...

Page 13: ...12...

Page 14: ...13...

Page 15: ...14...

Page 16: ...15...

Page 17: ...16...

Page 18: ...17...

Page 19: ...18...

Page 20: ......

Page 21: ...RATION MANUAL MODEL Ceilling Mounted Cassette type New Sensing Flow Model Air Conditioners FXFSQ25ARV16 FXFSQ32ARV16 FXFSQ40ARV16 FXFSQ50ARV16 FXFSQ63ARV16 FXFSQ80ARV16 FXFSQ100ARV16 FXFSQ125ARV16 FXF...

Page 22: ...reading the manual life it away for future reference Furthermore make certain that this operation manual is handed to a new user when he takes over the operation As this operation manual is dedicated...

Page 23: ...ust be done by a qualified installer in accordance with relevant local and national legislation Air conditioners must be treated at a specialized treatment facility for re use recycling and recovery B...

Page 24: ...at the leakage is repaired Consult your local dealer regarding what to do in case of refrigerant leakage When the air conditioner is installed in a small room it is necessary to take proper measures s...

Page 25: ...directly beneath the indoor or outdoor units Under certain conditions condensation on the unit or refrigerant piping air lter dirt or drain blockage may cause dripping resulting in fouling or failure...

Page 26: ...Do not leave the remote controller wherever there is a risk of wetting If water gets into the remote controller there is a risk of electrical leakage and damage to electronic components Be careful of...

Page 27: ...ter leakage If it occurs stop the air conditioner and consult This sound is heard when cooling operation stop the drain pump operates and then stop Wait approximately 5 minutes with your local dealer...

Page 28: ...e reverse order mentioned in the clause 2 5 Close the suction grille Slowly lift the suction grille and nally securely fasten it to the main body of the decoration panel while pressing the two knobs N...

Page 29: ...tion and deformation 6 Attach the air lter Refer to clause 4 for HOWTO CLEANTHE AIR FILTER Page 4 7 Attach the suction grille Attach the suction grille in the reverse order mentioned in the clause 3 8...

Page 30: ...12th Floor Building No 9 Tower A DLF Cyber City DLF Phase III Gurugram 122002 Haryana India DAIKIN AIRCONDITIONING INDIA PVT LTD 3P714597 1A...

Reviews: