12. WIRING DIAGRAM

INDOOR UNIT

A1P.........................PRINTED CIRCUIT BOARD

C105.......................CAPACITOR

PS...........................POWER SUPPLY CIRCUIT

F1U.........................FUSE (T, 3,15A, 250V)

F2U.........................FIELD FUSE

HAP ........................LIGHT EMITTING DIODE (SERVICE 

MONITORING –GREEN)

M1F ........................MOTOR (FAN)

M1P ........................MOTOR (DRAIN PUMP)

Q1DI .......................EARTH LEAK DETECTOR

R1T.........................THERMISTOR (AIR) 

R2T, R3T ................THERMISTOR (COIL)

S1L .........................FLOAT SWITCH

V1R ........................DIODE BRIDGE

X1M ........................TERMINAL BLOCK (CONTROL)

X2M ........................TERMINAL BLOCK (POWER SUPPLY)

Y1E.........................ELECTRONIC EXPANSION VALVE

Z1F .........................NOISE FILTER

Z1C.........................FERRITE CORE (NOISE FILTER)

RECEIVER/DISPLAY UNIT

A2P ........................ PRINTED CIRCUIT BOARD

A3P ........................ PRINTED CIRCUIT BOARD

BS1 ........................ PUSH BUTTON (ON/OFF)

H1P ........................ LIGHT EMITTING DIODE (ON-RED)

H2P ........................ LIGHT EMITTING DIODE (FILTER DING-RED)

H3P ........................ LIGHT EMITTING DIODE (TIMER-GREEN)

H4P ........................ LIGHT EMITTING DIODE (DEFROST-ORANGE)

SS1 ........................ SELECTOR SWITCH (MAIN/SUB)

SS2 ........................ SELECTOR SWITCH (WIRELESS ADRESS SET)

ADAPTOR FOR WIRING

KHuR ..................... MAGNETIC RELAY

KFR........................ MAGNETIC RELAY

KCR ....................... MAGNETIC RELAY

F3U, F4U ............... FUSE ( (B), 5A, 250V)

CONNECTOR FOR OPTIONAL PARTS

X24A ...................... CONNECTOR (WIRELESS REMOTE 

CONTROLLER)

X33A ...................... CONNECTOR (ADAPTOR FOR WIRING)

X35A ...................... CONNECTOR (POWER SUPPLY CONNECTOR)

X38A ...................... CONNECTOR (MULTI TENANT)

WIRED REMOTE CONTROLLER

R1T ........................ THERMISTOR (AIR)

SS1 ........................ SELECTOR SWITCH (MAIN/SUB)

: FIELD WIRING

BLK

: BLACK

PRP

: PURPLE

: CONNECTOR

BLU

: BLUE

RED

: RED

: WIRE CLAMP

BRN

: BROWN

WHT

: WHITE

: PROTECTIVE EARTH (SCREW)

GRY

: GREY

YLW

: YELLOW

L

: LIVE

ORG

: ORANGE

GRN

: GREEN

N

: NEUTRAL

PNK

: PINK

WIRED REMOTE CONTROLLER

:

Wired remote controller

(OPTIONAL ACCESSORY)

:

(Optional accessory)

SWITCH BOX (INDOOR)

:

Switch box (indoor)

TRANSMISSION WIRING

:

Transmission wiring

CENTRAL REMOTE CONTROLLER

:

Central remote controller

INPUT FROM OUTSIDE

:

Input from outside

NOTE

1.

USE COPPER CONDUCTORS ONLY.

2.

WHEN USING THE CENTRAL REMOTE CONTROLLER, SEE MANUAL FOR CONNECTION TO THE UNIT.

3.

WHEN CONNECTING THE INPUT WIRES FROM OUTSIDE, FORCED "OFF" OR "ON/OFF" CONTROL OPERATION CAN
BE SELECTED BY THE REMOTE CONTROLLER. SEE INSTALLATION MANUAL FOR MORE DETAILS.

4.

REMOTE CONTROLLER MODEL VARIES ACCORDING TO THE COMBINATION SYSTEM, CONFIRM ENGINEERING
DATA AND CATALOGS, ETC. BEFORE CONNECTING.

4PEN365593-1A.book  Page 15  Tuesday, June 9, 2015  2:44 PM

Summary of Contents for VRV FXDQ15P2VE

Page 1: ...INSTALLATION MANUAL FXDQ15P2VE FXDQ20P2VE FXDQ25P2VE FXDQ32P2VE FXDQ40P2VE FXDQ50P2VE FXDQ63P2VE System Inverter Air Conditioners 4PEN365593 1A book Page 1 Tuesday June 9 2015 2 44 PM...

Page 2: ...por B de acuerdo con el Certificado C 06 Nota delineato nel A e giudicato positivamente da B secondo il Certificato C 07 A B C 08 Nota tal como estabelecido em A e com o parecer positivo de B de acor...

Page 3: ...phoons or earthquakes Failure to do so during installation work may result in the unit falling and causing accidents Make sure that a separate power supply circuit is provided for this unit and that a...

Page 4: ...to the unit When moving the unit at or after opening hold the unit by the hanger brackets Do not apply force to the refrigerant piping drain piping or flange parts Be sure to check the type of R410A...

Page 5: ...talled as far away from fluores cent lighting as possible 2 Use suspension bolts for installation Check whether the ceiling is strong enough to support the weight of the unit or not If there is a risk...

Page 6: ...to prevent shaking Consult an architect or carpenter for details 4 Install the suspension bolts Use W3 8 to M10 suspension bolts Use a hole in anchor for existing ceilings and a sunken insert sunken a...

Page 7: ...ation may form on the surface of the insulation if the temperature above the ceiling reaches 30 C or the humidity RH80 CAUTION Follow the points below Use a pipe cutter and flare suitable for the type...

Page 8: ...se phosphor copper brazer BCuP 2 JIS Z 3264 B Cu93P 710 795 ISO 3677 which does not require flux Using a flux containing chlorine may cause the piping to corrode Using a welding flux containing fluori...

Page 9: ...efer to Fig 13 PRECAUTIONS Drain piping connections Do not connect the drain piping directly to sewage pipes that smell of ammonia The ammonia in the sewage might enter the indoor unit through the dra...

Page 10: ...ection area with aluminum tape or something similar to prevent air escaping CAUTION When attaching a duct to the intake side be sure to attach an air filter inside the air passage on the intake side U...

Page 11: ...ls Do not turn on the power supply circuit breaker or earth leak age breaker until all other work is done 9 2 SPECIFICATIONS FOR FIELD SUPPLIED FUSES AND WIRE Power related NOTES 1 Shows only in case...

Page 12: ...power sup ply wiring to the remote controller or transmission wiring terminal block Doing so can destroy the entire system Connecting electrical wiring remote controller wiring and transmission wirin...

Page 13: ...em For group control or use with 2 remote controllers Terminal block Tightening torque N m Remote controller transmission wiring terminal block 6P 0 79 0 97 Power supply wiring terminal block 3P 1 18...

Page 14: ...WORK 3 Remove the control box lid 4 Add remote controller 2 SUB to the terminal block for remote controller P1 P2 in the control box There is no polarity L N F F1 2 F F1 2 F F1 2 F F1 2 IN D IN D OUT...

Page 15: ...should be selected by selecting the SECOND CODE NO as shown in the table below The SECOND CODE NO is set to 01 when shipped Input A of forced off and ON OFF operation work as shown in the table below...

Page 16: ...f the following there is a possi bility that the wiring was done incorrectly or that the power is not on so check again CAUTION Always stop the test run using the remote controller to stop operation 4...

Page 17: ...24A CONNECTOR WIRELESS REMOTE CONTROLLER X33A CONNECTOR ADAPTOR FOR WIRING X35A CONNECTOR POWER SUPPLY CONNECTOR X38A CONNECTOR MULTI TENANT WIRED REMOTE CONTROLLER R1T THERMISTOR AIR SS1 SELECTOR SWI...

Page 18: ...4P365593 1A 2015 06 Copyright 2013 Daikin 4PEN365593 1A book Page 1 Tuesday June 9 2015 2 44 PM...

Reviews: