Operation with the remote control exclusively for Air 
conditioning operation HRV units (BRC301B61)

For non-independent systems, starting/stopping operation and timer
operation may not be possible.

Use the air conditioner remote control or the Centralized controller in
such cases.

 

BRC301B61: Remote controller for HRV

1.

Operation lamp
This pilot lamp (red) lights up while the unit is in operation.

2.

Operation/Stop button
When pushed once, the unit starts operating.
When pushed again, the unit stops.

3.

Air flow rate changeover button
Air flow rate can be changed over to “

” Low mode or 

” High mode, 

 FRESH UP” Low FRESH UP mode, 

 FRESH UP” High FRESH UP mode.

For “FRESH UP” operation
When this indication does not show: The volume of outdoor air
supplied into the room and that of the room air exhausted
outdoors is equivalent.
For “FRESH UP” operation

If it is set to “Fresh up air supply”: The volume
of outdoor air supplied into the room is larger
than that of room air exhausted outdoors.
(This operation prevents the odor and moisture
from kitchens and toilets from flowing into the
rooms.)
This is the factory setting.

If it is set to “Fresh up air exhaust”: The volume
of room air exhausted outdoors is larger than
that of outdoor air supplied into the room.
(This operation prevents the hospital odor and
floating bacteria from flowing out to the
corridors.)
To change the setting, refer to chapter 

“Local settings“ in the

installation manual.

4.

Ventilation mode changeover button

” Automatic mode. 

The temperature sensor of the unit automatically
changes the ventilation of the unit in Bypass mode and
Heat Exchange mode.

” Heat Exchange mode. 

In this mode, the air passes through the heat
exchanger element to effect Total Heat Exchanging
ventilation.

” Bypass mode. 

In this mode, the air does not pass through the heat
exchange element but by passes it to effect Bypass
ventilation.

5.

Indication of operation control method:  
When the operation of HRVs are linked with the air conditioners,
this indication may be shown.
While the indication is shown, the ON/OFF of HRVs cannot be
operated by the HRV remote controller.

6.

Indication of operation standby: 
It indicates the precooling/preheating operation. This unit is at
stop and will start operation after the precooling/preheating
operation is over.
Precooling/preheating operation means the operation of HRVs is
delayed during the startup operation of linked air conditioners,
for example before the office hours.
During this period the cooling or heating load is reduced to bring
the room temperature to the set temperature in a short time.

7.

Indication of centralized control: 
When a remote controller for air conditioners or devices for
centralized control are connected to the HRVs, this indication
may show.
When this indication appears on the display, the ON/OFF and
timer operation may not be possible with the HRV remote
controllers.

8.

Indication of air filter cleaning
When the indication “

” appears on the display, clean the filter.

9.

Filter signal reset button

10.

Inspection button
This button is to be used only for service. It is not to be used
normally.

How to operate with timer

11.

Schedule timer button “

/

”. 

This button enables or disables the schedule timer.

12.

Push the time adjust button “

” to set the time.

13.

Push the programming button “

”/ “

Then, the reservation is finished.

(              )

BRC301B61

A

HRV

TEST

FRESH  UP

hr

hr

6

8

4

3

9

5

7

1

2

11

13

10

12

FRESH  UP

FRESH  UP

A

(

(

A

(

(

Summary of Contents for VAM1000FC

Page 1: ...OPERATION MANUAL VAM350FC VAM500FC VAM650FC VAM800FC VAM1000FC VAM1500FC VAM2000FC Total Heat Exchanger HRV Heat Reclaim Ventilation Ceiling mounted duct type ...

Page 2: ...1 1 1 2 3 5 11 10 7 6 9 8 4 12 17 16 14 13 15 2 2 11 1 2 3 5 10 7 6 9 8 4 12 17 16 14 13 15 ...

Page 3: ...7 7 3 3 1 3 2 1 3 2 A B 6 6 4 4 1 2 4 3 1 2 4 3 A B 5 5 ...

Page 4: ...ric shock may occur Never inspect or service the unit by yourself Ask a qualified service person to perform this work Always use the air filter If the air filter is not used heat exchange elements will be clogged possibly causing poor performance and subsequent failure Do not change operations suddenly It can result not only in malfunction but also failure of switches or relays in the body This ap...

Page 5: ...the indoor unit and the HRV unit can be performed using the indoor remote controllers Refer to the section Operation with the remote control exclusively for Air conditioning operation HRV units BRC301B61 on page 3 Centralized system Operation method When the HRV remote controllers is not connected the Centralized controller controls the operation of the HRV unit Refer to the section Independent op...

Page 6: ...tilation of the unit in Bypass mode and Heat Exchange mode Heat Exchange mode In this mode the air passes through the heat exchanger element to effect Total Heat Exchanging ventilation Bypass mode In this mode the air does not pass through the heat exchange element but by passes it to effect Bypass ventilation 5 Indication of operation control method When the operation of HRVs are linked with the ...

Page 7: ...pears on the display clean the filter of the HRV unit Refer to the section Maintenance on page 4 Maintenance for a qualified service person only Maintenance for the air filter Cleaning frequency At least once every two years for general office use clean more frequently if necessary 1 Go into the ceiling through the inspection hole remove binding metal of maintenance cover and take it off Refer to ...

Page 8: ...vent such as gasoline and thinner on the air filter Be sure to install the air filter after servicing Missing air filter causes clogged heat exchange element Replacement air filters are available CAUTION Never wash the heat exchanger element with water Conditions Causes Corrective actions The unit does not operate at all Check if there is a power failure After power has been restored start operati...

Page 9: ...00FC Total Heat Exchanger HRV Heat Reclaim Ventilation 4P415945 1 2015 08 Operation manual 6 Disposal requirements Dismantling of the unit must be done in accordance with relevant local and national legislation ...

Page 10: ......

Page 11: ......

Page 12: ...4P415945 1 2015 08 Copyright 2015 Daikin ...

Reviews: