• Split Sky Air • Indoor Units

5

• Indoor Units • R-410A • CTXG-EV1BW_EV1BS

3

Dimensional drawing & centre of gravity

3 - 1 Dimensional drawing

3D050965

CTXG50E

unit (mm)

Left

Rear

Right

The mark (

Y

) shows piping direction

Signal receiver

Bottom

Reduction gear unit fixed screws (inside panel)

Front grille fixing screws (Inside)

Timer lamp

Operation lamp

Signal transmitter

Infrared remote control

Up/down (automatic)

Blade angles

Right/left (manual)

Air flow (indoor)

(space for

maintenance)

(Including mounting plate)

Name plate

Earth terminal
(M4, Inside panel)

(space

for

performance)

(space for maintenance)

Liquid pipe

J

6.4 CuT (the length of

pipe outside the unit: about 390)

Gas pipe 12.7Cut (The

length of pipe outside

the unit: about 340)

Drain hose (connecting part I.D.

J

14.0, O.D.

J

18.0)

(The hose length on the
outside of the unit is
approx. 440)

Wall hole for embedded piping

J

65

hole

Wall hole

J

65

hole

Standard locations of wall holes

Cooling

Indoor unit ON/OFF switch

Heating

Intelligent eye lamp

Room temp. thermistor (Inside)

(ARC433A41)

Dry

Room temperature thermistor (bottom

view)

Intelligent eye sensor

Fan

50 Min.

30

Min.

50 Min.

Installation

Required space

Terminal block
with earth
terminal (inside)

Up and down wind
direction control
blade movable
range

Operating state

Summary of Contents for Super Multi Plus E-Series CTXG50EV1BW

Page 1: ...technical data CTXG EV1BW_EV1BS Wall Mounted Inverter Controlled Unit air conditioning systems Split Sky Air...

Page 2: ...EV1BS 1 Features 2 2 Specifications 3 For indoor units only 3 Technical Specifications 3 Electrical Specifications 4 3 Dimensional drawing centre of gravity 5 Dimensional drawing 5 Centre of gravity 6...

Page 3: ...by activating the comfort mode The new titanium apatite photocatalytic air purification filter increases the active surface area for effective purification and deodorisation Horizontal and vertical au...

Page 4: ...Flow Rate Cooling High m min 11 3 11 3 Medium m min 9 1 9 1 Low m min 7 1 7 1 Silent Operation m min 6 7 6 7 Heating High m min 12 6 12 6 Medium m min 10 6 10 6 Low m min 8 7 8 7 Silent Operation m mi...

Page 5: ...Mounting plate Quantity 1 1 Notes Sound values are measured in an anechoic room Sound pressure level is a relative value depending on the distance and acoustic environment For more details please refe...

Page 6: ...Inside panel space for performance space for maintenance Liquid pipe J6 4 CuT the length of pipe outside the unit about 390 Gas pipe 12 7Cut The length of pipe outside the unit about 340 Drain hose co...

Page 7: ...Indoor Units R 410A CTXG EV1BW_EV1BS 3 Split Sky Air Indoor Units 6 3 Dimensional drawing centre of gravity 3 2 Centre of gravity 4D050964 CTXG E...

Page 8: ...r Units 7 Indoor Units R 410A CTXG EV1BW_EV1BS 4 Piping diagram 4D050924 CTXG50E Indoor unit Heat exchanger Cross flow fan Fan motor Field piping Field piping Refrigerant flow Thermistor on heat excha...

Page 9: ...ircuit board R1T R2T Thermistor S1 S51 Connector S1W Operation switch S2W Panel limit switch X1M Terminal strip E1 Earth terminal shield plate E2 Earth terminal heat ex Signal receiver CAUTION Note th...

Page 10: ...e Legend 50 60Hz 220 240 220 230V H 50 60Hz 220 240 220 230V L NOTE 1 Operation noise differs with operation and ambient conditions Location of microphone 3D050972 Octave band sound pressure level dB...

Page 11: ......

Page 12: ...in Belgium by Lannoo The present publication is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N V Daikin Europe N V has compiled the content of this...

Reviews: