11

To change the airflow rate setting

5. Press “FAN setting button”.

• Indoor unit quiet operation

When the airflow is set to “

”, the noise from the indoor unit will become quieter. 

Use this when making the noise quieter.

NOTE 

DRY mode

AUTO or COOL or HEAT or FAN mode

The airflow rate setting is not variable.

Five levels of airflow rate setting from “ ” to “

” 

plus “

” “

” are available.

Note on HEAT operation

• Since this air conditioner heats the room by taking heat from outdoor air to indoors, the heating 

capacity becomes smaller in lower outdoor temperatures.  If the heating effect is insufficient, it 
is recommended to use another heating appliance in combination with the air conditioner.

• The heat pump system heats the room by circulating hot air around all parts of the room.  

After the start of heating operation, it takes some time before the room gets warmer.

• In heating operation, frost may occur on the outdoor unit and lower the heating capacity.  In 

that case, the system switches into defrosting operation to take away the frost.

• During defrosting operation, hot air does not flow out of indoor unit.
• A pinging sound may be heard during defrosting operation, which, however does not mean 

that the air conditioner has failures.

Note on COOL operation

• This air conditioner cools the room by blowing the hot air in the room outside, so if the 

outside temperature is high, the performance of the air conditioner drops.

Note on DRY operation

• The computer chip works to rid the room of humidity while maintaining the temperature as 

much as possible. It automatically controls temperature and airflow rate, so manual 
adjustment of these functions is unavailable.

Note on AUTO operation

• In AUTO operation, the system selects a temperature setting and an appropriate operation 

mode (COOL or HEAT) based on the room temperature at the start of the operation.

• The system automatically reselects setting at a regular interval to bring the room 

temperature to user-setting level.

• If you do not like AUTO operation, manually change the set temperature.

Note on airflow rate setting

• At smaller airflow rates, the cooling (heating) effect is also smaller.

01_EN_3P207037-1.fm  Page 11  Monday, September 10, 2007  5:16 PM

Summary of Contents for Super Multi NX FTXS20G2V1B

Page 1: ...n ais Nederlands Espa ol Italiano Portugues DAIKIN ROOM AIR CONDITIONER Operation Manual T rk e MODELS FTXS20G2V1B FTXS25G2V1B FTXS35G2V1B FTXS42G2V1B FTXS50G2V1B 00_CV_3P207037 1 fm Page 1 Tuesday Ju...

Page 2: ...djusting the Airflow Direction 12 COMFORT AIRFLOW and INTELLIGENT EYE Operation 14 POWERFUL Operation 17 OUTDOOR UNIT QUIET Operation 18 ECONO Operation 19 TIMER Operation 20 WEEKLY TIMER Operation 22...

Page 3: ...tempt to install the air conditioner by your self Incorrect work will result in water leakage electric shocks or fire For installation consult the dealer or a qualified technician In order to avoid el...

Page 4: ...for small animals which can enter the unit Once in the unit such animals can cause malfunctions smoke or fire when making contact with electrical parts Do not operate the air conditioner with wet hand...

Page 5: ...4 Names of parts Indoor Unit 16 14 13 15 12 1 3 4 5 7 9 11 10 8 6 2 01_EN_3P207037 1 fm Page 4 Monday September 10 2007 5 16 PM...

Page 6: ...mode refers to the following table This switch is useful when the remote controller is missing 13 Operation lamp green 14 TIMER lamp yellow page 20 15 INTELLIGENT EYE lamp green page 14 16 Signal rece...

Page 7: ...page 10 8 QUIET button OUTDOOR UNIT QUIET operation page 18 9 ECONO button ECONO operation page 19 10 SWING button Horizontal blades flaps page 12 11 SWING button Vertical blades louvers page 12 12 CO...

Page 8: ...s not used for a long time take the batteries out The batteries will last for approximately one year If the remote controller display begins to fade and the degradation of reception performance occurs...

Page 9: ...present time Holding down or button rapidly increases or decreases the time display 5 Press CLOCK button Always point the remote controller at the indoor unit when pushing the buttons when setting the...

Page 10: ...to use the air conditioner for a long period for example in spring or autumn turn the breaker OFF Use the air conditioner in the following conditions The operation of the system outside the above humi...

Page 11: ...ting in sequence AUTO DRY COOL HEAT FAN 2 Press ON OFF button The OPERATION lamp lights up To stop operation 3 Press ON OFF button again Then OPERATION lamp goes off To change the temperature setting...

Page 12: ...ation to take away the frost During defrosting operation hot air does not flow out of indoor unit A pinging sound may be heard during defrosting operation which however does not mean that the air cond...

Page 13: ...en the flaps have reached the desired position press SWING button once more The flaps will stop moving disappears from the LCD To adjust the vertical blades louvers 3 Press SWING button is displayed o...

Page 14: ...old air which tends to collected at the bottom of the room and hot air which tends to collect near the ceiling throughout the room preventing areas of cold and hot developing ATTENTION Always use a re...

Page 15: ...isplayed on the LCD To cancel operation 2 Press COMFORT SENSOR button Press the button to select Blank Display Operation mode Explanation COMFORT AIRFLOW The flaps will adjust the airflow direction up...

Page 16: ...will be directed upward The flaps will move downward while heating so that the airflow will be directed downward The INTELLIGENT EYE sensor according to the following situations Cooling operation Heat...

Page 17: ...oth of them are in use the air conditioner will not direct the airflow towards the people Sensor may not detect moving objects further than 5m away Check the application range Sensor detection sensiti...

Page 18: ...used together with ECONO QUIET or COMFORT Operation Priority is given to the function of whichever button is pressed last POWERFUL Operation can only be set when the unit is running Pressing the oper...

Page 19: ...m the LCD NOTE Note on OUTDOOR UNIT QUIET operation If using a multi system this function will work only when the OUTDOOR UNIT QUIET operation is set on all operated indoor units However if using prio...

Page 20: ...E ECONO Operation can only be set when the unit is running Pressing the OFF button causes the setting to be canceled and the disappears from the LCD ECONO operation is a function which enables efficie...

Page 21: ...ly 3 Press OFF TIMER button again The TIMER lamp lights up To cancel the OFF TIMER Operation 4 Press CANCEL button The TIMER lamp goes off NOTE When TIMER is set the present time is not displayed Once...

Page 22: ...ly 3 Press ON TIMER button again The TIMER lamp lights up To cancel ON TIMER operation 4 Press CANCEL button The TIMER lamp goes off To combine ON TIMER and OFF TIMER A sample setting for combining th...

Page 23: ...making reservations The use of ON ON ON ON settings for example makes it possible to schedule operating mode and set temperature changes Furthermore by using OFF OFF OFF OFF settings only the turn OF...

Page 24: ...esired mode and or will flash Go to STEP 9 if no setting is selected 5 Press NEXT button The weekly mode will be set and blink 6 Press SELECT button to select the desired time The time can be set betw...

Page 25: ...s just before the operation Both WEEKLY TIMER and ON OFF timer cannot be used at the same time The ON OFF timer has priority if it is set while WEEKLY TIMER is still active WEEKLY TIMER is activated a...

Page 26: ...on of the selected day of the week will be copied To continue copying the settings to other days of the week repeat STEP 4 and STEP 5 6 Press button Exit copy mode NOTE COPY MODE The entire reservatio...

Page 27: ...ng tone This operation is not effective while WEEKLY TIMER is being set All reservations will be canceled Canceling individual reservations This function can be used for canceling reservations for eac...

Page 28: ...retailer or dealer for assistance NIGHT QUIET Mode reduces the operation noise of the outdoor unit during the night time hours to prevent annoyance to neighbors The NIGHT QUIET Mode is activated when...

Page 29: ...m A enters POWERFUL operation operation capacity will be concentrated in Room A In such a case the cooling heating efficiency of the units in Rooms B C and D may be slightly reduced 3 Priority when us...

Page 30: ...nd push them in all the way Close the front panel slowly and push the panel at the 3 points 1 on each side and 1 in the middle CAUTION Units Don t touch the metal parts of the indoor unit If you touch...

Page 31: ...hinned with lukewarm water then dry them up in the shade It is recommended to clean the air filters every 2 weeks Titanium Apatite Photocatalytic Air Purifying Filter The Titanium Apatite Photocatalyt...

Page 32: ...there you bought the air conditioner Dispose of the old filter as non flammable waste Check that the base stand and other fittings of the outdoor unit are not decayed or corroded Check that nothing bl...

Page 33: ...oor unit gives out odour This happens when smells of the room furniture or cigarettes are absorbed into the unit and discharged with the airflow If this happens we recommend you to have the indoor uni...

Page 34: ...hat the lamps are normal If the lamps stop flashing after the above steps there is no malfunction page 27 An abnormal functioning happens during operation The air conditioner may malfunction with ligh...

Page 35: ...Please contact the installer or local authority for more information Batteries must be removed from the remote controller and disposed of separately in accordance with relevant local and national leg...

Page 36: ...UCTION AIR TEMPERATURE SENSOR OUTDOOR UNIT EA COOLING HEATING SWITCHING ERROR E1 CIRCUIT BOARD FAULT E5 OL STARTED E6 FAULTY COMPRESSOR START UP E7 DC FAN MOTOR FAULT E8 OVERCURRENT INPUT F3 HIGH TEMP...

Page 37: ...UNIT FAULTY COMPRESSOR START INPUT OVERCURRENT HIGH TEMPERATURE SWITCHBOX HIGH TEMPERATURE AT INVERTER CIRCUIT HEATSINK LOW VOLTAGE TO MAIN CIRCUIT OR MOMENTARY VOLTAGE LOSS REVERSING SOLENOID VALVE...

Page 38: ...0711 HT 3P207037 1 M07B014 Two dimensional bar code is a code for manufacturing 00_CV_3P207037 1 fm Page 2 Tuesday June 5 2007 10 38 AM...

Reviews: