background image

A

DVANCED

F

EATURES

THAT

MAKE A

D

IFFERENCE

Easy

 

Installation

A

 

Daikin

 

Inverter

 

Ducted

 

outdoor

 

unit

 

is

 

not

 

as

 

large

 

and

 

bulky

 

as

 

the

 

outdoor

 

unit

 

on

 

a

 

conventional

 

system.

 

More

 

than

 

one

 

of

 

the

 

compact

 

and

 

lightweight

 

units

 

can

 

be

 

fitted

 

in

 

the

 

bed

 

of

 

a

 

standard

 

pickup

 

truck.

ƒ

Reduced

 

installation

 

time

 

with

 

integrated

 

electronic

 

expansion

 

valve

 

and

 

printed

 

circuit

 

boards

ƒ

Volt

free

 

float

 

switch

 

integration

 

option

ƒ

Corrosion

resistant

 

coating

 

on

 

outdoor

 

unit

 

heat

 

exchanger

ƒ

Indoor

 

fan

 

coil

 

unit

 

with

 

up

 

flow

 

or

 

horizontal

 

right

                                             

configurations

ƒ

Heating

 

and

 

Cooling

 

Fan

 

Auto

 

mode

 

can

 

be

                                                      

configured

 

separately

ƒ

Dual

voltage

 

208

230V/1/60

 

Hz

 

power

                                                              

supply

ƒ

Optional

 

electric

 

resistance

 

heat

ƒ

Gravity

fed

 

drain

 

connection

Feel

the

 

Difference

Designed

 

for

 

superior heating

 

capacity

 

in

 

low

ambient

 

conditions

 

and

 

absolute

 

comfort,

 

Daikin

 

Inverter

 

Ducted

 

units

 

provide

 

comfortable

 

heating

 

down

 

to

 

0°F,

 

with

 

up

 

to

 

100%

 

capacity

 

available

 

at

 

temperatures

 

as

 

low

 

as

 

14°F.

  

With

 

the

 

ability

 

to

 

operate

 

in

 

cooling

 

mode

 

from

 

23°F

 

to

 

115°F,

 

this

 

makes

 

installation

 

easier

 

in

 

most

 

climates

 

since

 

additional

 

supplemental

 

electric

 

heater

 

is

 

not

 

required.

Hear

the

 

Difference

Daikin

 

Inverter

 

Ducted

 

systems

 

have

 

sound

 

reducing

 

features

 

such

 

as

 

compressor

 

sound

 

attenuators,

 

but

 

they’re

 

also

 

quieter

 

than

 

conventional

 

systems

 

because

 

they

 

have

 

fewer

 

moving

 

parts

 

and

 

rarely

 

run

 

at

 

full

 

speed.

 

Utilizing

 

inverter

 

technology

 

to

 

maintain

 

comfort

 

settings,

 

Daikin

 

systems

 

most

 

often

 

operate

 

at

 

low

 

speeds

 

with

 

outdoor

 

sound

 

levels

 

in

 

the

 

mid

 

to

 

high

 

50s

 

dB(A).

 

Sound

 

levels

 

as

 

low

 

as:

Washing

 

Machine

Dryer

Average

 

Home

Quiet

 

Library

Quiet

 

Bedroom

 

at

 

Night

Normal

 

Breathing

Standard

 

Residential

 

Outdoor

 

Unit

Normal

 

Conversation

Daikin

 

Outdoor

 

Unit

Sound

 

recording

 

room

Whisper

Threshold

 

of

 

Hearing

Summary of Contents for SkyAir RZQ36PVJU9

Page 1: ...Daikin Inverter Ducted Heat Pump FTQ ...

Page 2: ...ode down to 0 F making them cheaper to run than traditional heat pump systems in most climates They are also more compact and quieter than traditional units Integrated with an inverter variable speed compressor systems deliver the capacity required to maintain desired room conditions reducing energy consumption by 30 compared to traditional fixed speed systems This technology minimizes temperature...

Page 3: ...bient conditions and absolute comfort Daikin Inverter Ducted units provide comfortable heating down to 0 F with up to 100 capacity available at temperatures as low as 14 F With the ability to operate in cooling mode from 23 F to 115 F this makes installation easier in most climates since additional supplemental electric heater is not required Hear the Difference Daikin Inverter Ducted systems have...

Page 4: ... 30 0 Power Consumption Cooling kW 1 19 1 68 2 06 2 65 3 05 Power Consumption Heating kW 1 41 1 98 2 53 3 03 4 02 Operating Current Cooling A 1 2 1 3 1 8 2 2 2 8 Operating Current Heating A 1 2 1 3 1 8 2 2 2 8 Indoor Units FTQ Unitary Model Name FTQ18PBVJU FTQ24PBVJU FTQ30PBVJU FTQ36PBVJU FTQ42PBVJU External Static Pressure W G Up to 0 50 Airflow H M L CFM 600 510 420 800 680 560 1 000 850 700 1 2...

Page 5: ...ies as follow This represents Daikin s free of mind guarantee to ensure full compatibility within the total system offered and top performance EASE OF INSTALLATION Space required for installation in H 19 1 8 Space required for installation in The installation of a secondary drain pan is necessary as shown below Always refer to installation manuals for details Connected by a pair of refrigerant lin...

Page 6: ...e User s Manual provides important safety instructions and warnings Be sure to follow these instructions and warnings For any inquiries contact your local Daikin sales office WARNINGS Organization DAIKIN INDUSTRIES LTD AIR CONDITIONING MANUFACTURING DIVISION Scope of Registration THE DESIGN DEVELOPMENT AND MANUFACTURE OF COMMERCIAL AIR CONDITIONING HEATING COOLING REFRIGERATING EQUIPMENT COMMERCIA...

Reviews: